The CCJR® Gerard A. Engh Excellence in Knee Research Award: Remote Monitoring of Sleep Disturbance Following Total Knee Arthroplasty: A Cautionary Note

Joseph T Gibian, Kimberly A Bartosiak, Venessa Riegler, Jackie King, Brendan P Lucey, Robert L Barrack

The Journal of Arthroplasty · 2024-08 · 39 (8) · S22-S26

DOI: 10.1016/j.arth.2024.03.065 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024-08. Verfasst von Joseph T Gibian und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Washington University School of Medicine, St. Louis, Missouri. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Sleep Wake Disorders, Wearable Electronic Devices. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Zimmer Biomet Holdings Inc.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Sleep disturbances are common after total knee arthroplasty (TKA). Despite the rising popularity of wearables to track sleep, little evidence exists in the arthroplasty literature regarding their efficacy. We aimed to correlate validated wearable sleep metrics with patient-reported sleep quality following TKA. METHODS: Patients undergoing primary TKA were consecutively enrolled. Patients used a wearable device preoperatively and 90 days postoperatively to track five previously-validated measures of sleep. Each month, they rated their sleep quality. Wearable sleep data was correlated with patient-reported sleep quality using a point biserial correlation test. Categorical data were compared using Chi-square tests. A total of 110 patients were included. RESULTS: Preoperatively, 20.8% of patients reported "fairly bad" or "very bad" sleep; this increased to 44.4% 30 days postoperatively, then decreased to 26.5% 60 days postoperatively, and to 20.2% 90 days postoperatively. At 30 days postoperatively, time in bed, time asleep, and minutes of rapid eye movement sleep weakly correlated with patient-reported sleep quality (correlations 0.356, 0.345, and 0.345, respectively; P < .001). Sleep quality did not correlate with any wearable metric collected 60 or 90 days postoperatively. CONCLUSIONS: Patient-reported sleep quality following TKA initially worsened postoperatively, then improved to preoperative levels by 90 days. Time in bed, time asleep, and rapid eye movement sleep minutes only weakly correlated with patient-reported sleep quality at 30 days; no other correlations were detected. Surgeons that utilize remote monitoring following TKA should be aware that surrogate measures generated from these devices may correlate weakly, if at all, with the patient-reported outcome of the parameter being studied.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeSleep Wake DisordersWearable Electronic DevicesHumansMaleFemaleAgedMiddle AgedAwards and PrizesPatient Reported Outcome MeasuresSleep QualityAged, 80 and overPostoperative Complications

Stichwörter der Autor:innen

patient reported outcomesremote monitoringsleep disturbancetotal knee arthroplastywearable devices

Autor:innen und Institutionen

  • Department of Orthopaedics, Washington University School of Medicine, St. Louis, Missouri.
  • Department of Neurology, Washington University School of Medicine, St. Louis, Missouri.

Förderung

  • Zimmer Biomet Holdings Inc

Zitieren

APA

Gibian, J. T., Bartosiak, K. A., Riegler, V., King, J., Lucey, B. P., & Barrack, R. L. (2024). The CCJR® Gerard A. Engh Excellence in Knee Research Award: Remote Monitoring of Sleep Disturbance Following Total Knee Arthroplasty: A Cautionary Note. The Journal of Arthroplasty, 39(8), S22-S26. https://doi.org/10.1016/j.arth.2024.03.065

Vancouver

Gibian JT, Bartosiak KA, Riegler V, King J, Lucey BP, Barrack RL. The CCJR® Gerard A. Engh Excellence in Knee Research Award: Remote Monitoring of Sleep Disturbance Following Total Knee Arthroplasty: A Cautionary Note. The Journal of Arthroplasty. 2024;39(8):S22-S26. doi:10.1016/j.arth.2024.03.065

BibTeX
@article{Gibian2024,
  author = {Gibian, Joseph T and Bartosiak, Kimberly A and Riegler, Venessa and King, Jackie and Lucey, Brendan P and Barrack, Robert L},
  title = {The CCJR® Gerard A. Engh Excellence in Knee Research Award: Remote Monitoring of Sleep Disturbance Following Total Knee Arthroplasty: A Cautionary Note},
  journal = {The Journal of Arthroplasty},
  year = {2024},
  volume = {39},
  number = {8},
  pages = {S22--S26},
  doi = {10.1016/j.arth.2024.03.065}
}