Clinical Outcomes and Risk Factors for Re-Revision Due to Trunnion Corrosion in Primary Metal-on-Polyethylene Total Hip Arthroplasty
The Journal of Arthroplasty · 2024-09 · 39 (9) · S404-S409
DOI: 10.1016/j.arth.2024.01.057 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024-09. Verfasst von Erden Ali und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine-Orthopaedics, The University of British Columbia, Diamond Health Care Centre, Vancouver, Canada. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Reoperation, Hip Prosthesis, Polyethylene. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 32 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: There is a paucity of literature regarding the mid-term (greater than 2 years) outcomes of revision for adverse local tissue reaction to metal debris due to corrosion at the head-neck junction (trunnionosis) in metal-on-polyethylene total hip arthroplasty (THA), and risk factors for re-revision remain largely unknown. We aimed to report the re-revision-free survival and functional outcomes for this patient population and to identify risk factors for re-revision. METHODS: A total of 80 hips (79 patients) with a metal-on-polyethylene THA who had undergone revision for trunnionosis at our institution were included. The mean study follow-up from index trunnionosis revision was 4.6 years (range, 2.0 to 9.4). Kaplan-Meier survival analysis was performed with all-cause re-revision as the end point, and multivariate logistic regression was used to identify risk factors for re-revision. RESULTS: We saw that twenty-one hips (26%) underwent re-revision at a mean of 8.0 months (range, 0.03 to 36.3) after the index trunnionosis revision, most commonly for instability and infection. The two- and five-year all-cause re-revision-free survival rates were 75.0 and 73.2%, respectively. The mean Oxford Hip Score was 33.7 (range, 11 to 48); 76% were satisfied, and 24% were dissatisfied with their hip. Multivariate analysis identified not undergoing a cup revision (odds ratio: 4.5; 95% confidence interval: 1.03 to 19.7) and time from primary THA to the index trunnionosis revision (odds ratio: 0.77; 95% confidence interval: 0.62 to 0.97) as risk factors for undergoing re-revision. CONCLUSIONS: The risk of early re-revision for these patients is high (26%), mostly due to infection and instability, and functional outcomes are fair. Not performing a cup revision appears to be a risk factor for re-revision, as is the shorter time from primary THA to trunnionosis revision. LEVEL OF EVIDENCE: III.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Medicine-Orthopaedics, The University of British Columbia, Diamond Health Care Centre, Vancouver, Canada.
Zitieren
APA
Ali, E., Neufeld, M. E., Howard, L. C., Masri, B. A., Greidanus, N. V., & Garbuz, D. S. (2024). Clinical Outcomes and Risk Factors for Re-Revision Due to Trunnion Corrosion in Primary Metal-on-Polyethylene Total Hip Arthroplasty. The Journal of Arthroplasty, 39(9), S404-S409. https://doi.org/10.1016/j.arth.2024.01.057
Vancouver
Ali E, Neufeld ME, Howard LC, Masri BA, Greidanus NV, Garbuz DS. Clinical Outcomes and Risk Factors for Re-Revision Due to Trunnion Corrosion in Primary Metal-on-Polyethylene Total Hip Arthroplasty. The Journal of Arthroplasty. 2024;39(9):S404-S409. doi:10.1016/j.arth.2024.01.057
BibTeX
@article{Ali2024,
author = {Ali, Erden and Neufeld, Michael E and Howard, Lisa C and Masri, Bassam A and Greidanus, Nelson V and Garbuz, Donald S},
title = {Clinical Outcomes and Risk Factors for Re-Revision Due to Trunnion Corrosion in Primary Metal-on-Polyethylene Total Hip Arthroplasty},
journal = {The Journal of Arthroplasty},
year = {2024},
volume = {39},
number = {9},
pages = {S404--S409},
doi = {10.1016/j.arth.2024.01.057}
}