Risk Factors Associated With Quadriceps Tendon Extensor Mechanism Disruption Following Total Knee Arthroplasty
The Journal of Arthroplasty · 2024-07 · 39 (7) · 1840-1844.e1
DOI: 10.1016/j.arth.2024.01.053 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024-07. Verfasst von Shu Lin und 5 weiteren Autor:innen. Beteiligte Einrichtung: Kiran C. Patel College of Allopathic Medicine, Nova Southeastern University, Fort Lauderdale, Florida. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Tendon Injuries, Quadriceps Muscle, Postoperative Complications. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Quadriceps tendon extensor mechanism disruption is an infrequent but devastating complication after total knee arthroplasty (TKA). Our knowledge of specific risk factors for this complication is limited by the current literature. Thus, this study aimed to identify potential risk factors for quadriceps tendon extensor mechanism disruption following TKA. METHODS: A retrospective cohort analysis was performed using the PearlDiver Administrative Claims Database. Patients undergoing TKA without a prior history of quadriceps tendon extensor mechanism disruption were identified. Quadriceps tendon extensor mechanism disruption included rupture of the quadriceps tendon, patellar tendon, or fracture of the patella. Patients who had a minimum of 5 years of follow-up after TKA were included. A total of 126,819 patients were included. Among them, 517 cases of quadriceps tendon extensor mechanism disruption occurred (incidence 0.41%). Hypothesized risk factors were compared between those who had postoperative quadriceps tendon extensor mechanism disruption and those who did not. RESULTS: On multivariate analysis, increased Charlson Comorbidity Index (odds ratio (OR): 1.10, 95% confidence interval (CI) [1.07 to 1.13]; P < .001), obesity (OR: 1.49, 95% CI [1.24 to 1.79]; P < .001), and fluoroquinolone use any time after TKA (OR: 1.24, 95% CI [1.01 to 1.52]; P = .036) were significantly associated with quadriceps tendon extensor mechanism disruption. CONCLUSIONS: Our study identified the incidence of quadriceps tendon extensor mechanism disruption following TKA as 0.41%. Identified risk factors for quadriceps tendon extensor mechanism disruption after TKA include an increased Charlson Comorbidity Index, obesity, and use of fluoroquinolones postoperatively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Kiran C. Patel College of Allopathic Medicine, Nova Southeastern University, Fort Lauderdale, Florida.
- Department of Orthopedic Surgery, George Washington Hospital, Washington, District of Columbia.
- Adult Reconstruction Division, Johns Hopkins Department of Orthopaedic Surgery, Columbia, Maryland.
- Department of Orthopaedic Surgery, Virginia Commonwealth University Health, Richmond, Virginia.
Zitieren
APA
Lin, S., Sproul, D., Agarwal, A., Harris, A. B., Golladay, G. J., & Thakkar, S. C. (2024). Risk Factors Associated With Quadriceps Tendon Extensor Mechanism Disruption Following Total Knee Arthroplasty. The Journal of Arthroplasty, 39(7), 1840-1844.e1. https://doi.org/10.1016/j.arth.2024.01.053
Vancouver
Lin S, Sproul D, Agarwal A, Harris AB, Golladay GJ, Thakkar SC. Risk Factors Associated With Quadriceps Tendon Extensor Mechanism Disruption Following Total Knee Arthroplasty. The Journal of Arthroplasty. 2024;39(7):1840-1844.e1. doi:10.1016/j.arth.2024.01.053
BibTeX
@article{Lin2024,
author = {Lin, Shu and Sproul, David and Agarwal, Amil and Harris, Andrew B and Golladay, Gregory J and Thakkar, Savyasachi C},
title = {Risk Factors Associated With Quadriceps Tendon Extensor Mechanism Disruption Following Total Knee Arthroplasty},
journal = {The Journal of Arthroplasty},
year = {2024},
volume = {39},
number = {7},
pages = {1840--1844.e1},
doi = {10.1016/j.arth.2024.01.053}
}
EUVIMED