EUVIMEDEUVIMED entdecken
Crossref

Can Dual Mobility Cups Reduce Revision and Dislocation Risks? An Analysis of 107,528 Primary Total Hip Arthroplasties in the United States

Monti Khatod, Priscilla H Chan, Heather A Prentice, Brian H Fasig, Elizabeth W Paxton, Nithin C Reddy, Matthew P Kelly

The Journal of Arthroplasty · 2024

DOI: 10.1016/j.arth.2023.11.026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024. Verfasst von Monti Khatod und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Southern California Permanente Medical Group, Los Angeles, California. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Joint Dislocations, Hip Dislocation. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Dual mobility acetabular cups (DMC) were designed to increase the effective femoral head size and improve stability with the goal of reducing revision risk at the potential cost of polyethylene thickness. We sought to evaluate revision risk following primary elective total hip arthroplasty with DMC compared to highly cross-linked polyethylene (XLPE). METHODS: A cohort study was conducted using data from a Kaiser Permanente's total joint arthroplasty registry. Patients ≥18 years who underwent primary elective total hip arthroplasty using DMC, unipolar Metal-on-XLPE (MoXLPE), or unipolar Ceramic-on-XLPE (CoXLPE) were identified (2010 to 2021). The final sample comprised 2,219 DMC, 48,251 MoXLPE, and 57,058 CoXLPE. Multiple Cox proportional hazard regressions were used to evaluate aseptic revision and any dislocation regardless of revision within 6 years follow-up. RESULTS: In adjusted analyses, no differences in aseptic revision risk were observed for MoXLPE (hazard ratio [HR] = 1.04, 95% confidence interval [CI] = 0.72 to 1.51) or CoXLPE (HR = 0.98, 95% CI = 0.69 to 1.40) compared to DMC. No differences in dislocation risk were observed for MoXLPE (HR = 1.42, 95% CI = 0.93 to 2.15) or CoXLPE (HR = 1.25, 95% CI = 0.84 to 1.87) compared to DMC. CONCLUSIONS: In a US-based cohort, 6-year aseptic revision risk of DMC was similar to metal or ceramic femoral head unipolar constructs. Furthermore, no difference in dislocation risk was observed. Continued longer-term follow-up may reveal if there is a reduced risk of dislocation that comes at the cost of increased late revision. LEVEL OF EVIDENCE: Level III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisJoint DislocationsHip DislocationHumansUnited StatesCohort StudiesProsthesis FailureProsthesis DesignReoperationPolyethyleneMetalsRetrospective Studies

Stichwörter der Autor:innen

dislocationdual mobility cuphighly cross-linked polyethylenerevisiontotal hip arthroplasty

Substanzen

PolyethyleneMetals

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Southern California Permanente Medical Group, Los Angeles, California.
  • Medical Device Surveillance and Assessment, Kaiser Permanente, San Diego, California.
  • Department of Orthopaedic Surgery, Southern California Permanente Medical Group, San Diego, California.
  • Department of Orthopaedic Surgery, Southern California Permanente Medical Group, Harbor City, California.

Zitieren

APA

Khatod, M., Chan, P. H., Prentice, H. A., Fasig, B. H., Paxton, E. W., Reddy, N. C., & Kelly, M. P. (2024). Can Dual Mobility Cups Reduce Revision and Dislocation Risks? An Analysis of 107,528 Primary Total Hip Arthroplasties in the United States. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2023.11.026

Vancouver

Khatod M, Chan PH, Prentice HA, Fasig BH, Paxton EW, Reddy NC, et al. Can Dual Mobility Cups Reduce Revision and Dislocation Risks? An Analysis of 107,528 Primary Total Hip Arthroplasties in the United States. The Journal of Arthroplasty. 2024. doi:10.1016/j.arth.2023.11.026

BibTeX
@article{Khatod2024,
  author = {Khatod, Monti and Chan, Priscilla H and Prentice, Heather A and Fasig, Brian H and Paxton, Elizabeth W and Reddy, Nithin C and Kelly, Matthew P},
  title = {Can Dual Mobility Cups Reduce Revision and Dislocation Risks? An Analysis of 107,528 Primary Total Hip Arthroplasties in the United States},
  journal = {The Journal of Arthroplasty},
  year = {2024},
  doi = {10.1016/j.arth.2023.11.026}
}
Kostenlos starten →