EUVIMEDEUVIMED entdecken
Crossref

Excellent 20-Year Results of Total Hip Arthroplasty With Highly Cross-Linked Polyethylene on Cobalt-Chromium Femoral Heads in Patients ≤50 Years

Frank W Parilla, Tyler R Youngman, Daniel R Layon, Deniz C Ince, Gail E Pashos, William J Maloney, John C Clohisy

The Journal of Arthroplasty · 2024-02 · 39 (2) · 409-415

DOI: 10.1016/j.arth.2023.08.025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2024-02. Verfasst von Frank W Parilla und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Osteolysis. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 56 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Highly cross-linked polyethylene (HXLPE) acetabular bearing surfaces have appeared to offer excellent wear resistance, low incidence of wear-related osteolysis, and high implant survivorship at 10-year to 15-year follow-up. However, concerns over potential performance deterioration at longer-term follow-up remain - particularly in younger patients - and outcome data into the third decade have not been available. METHODS: We retrospectively assessed 62 patients (68 hips) who underwent primary total hip arthroplasty (THA) at age ≤50 years with a single manufacturer's cementless components, remelted HXLPE liner, and small diameter (26 and 28 millimeter) cobalt-chromium (CoCr) femoral heads at minimum 18-year follow-up. We assessed clinical outcomes (modified Harris Hip score, University of California Los Angeles Activity Score, polyethylene wear rates, radiographic findings (osteolysis, component loosening), and implant survivorship. RESULTS: At 20.6-year mean follow-up (range, 18 to 23 years) modified Harris Hip scores for surviving hips remained an average of 41 points above preoperative baseline (49 versus 90, P < .001) and UCLA scores 2.8 points above baseline (3.7 versus 6.4, P < .001). Wear analysis revealed a population linear wear rate of 0.0142 mm/y (standard deviation (SD), 0.0471) and volumetric wear rate of 10.14 mm3/y (SD, 23.41). Acetabular lysis was noted in 2 asymptomatic hips at 16.6 and 18.4 years. No components were radiographically loose. Survivorship free from wear-related revision was 100% at 20 years (97% free from any revision). CONCLUSION: The HXLPE-CoCr bearing couple with small femoral heads continues to be extremely effective 20 years after primary THA in the younger patient population.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, HipHip ProsthesisOsteolysisHumansMiddle AgedPolyethyleneRetrospective StudiesChromiumCobaltFemur HeadProsthesis FailureProsthesis DesignFollow-Up Studies

Stichwörter der Autor:innen

THAbearingspolyethylenetotal hip arthroplastywearyoung

Substanzen

PolyethyleneChromiumCobalt

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, Missouri.
  • Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, California.

Zitieren

APA

Parilla, F. W., Youngman, T. R., Layon, D. R., Ince, D. C., Pashos, G. E., Maloney, W. J., & Clohisy, J. C. (2024). Excellent 20-Year Results of Total Hip Arthroplasty With Highly Cross-Linked Polyethylene on Cobalt-Chromium Femoral Heads in Patients ≤50 Years. The Journal of Arthroplasty, 39(2), 409-415. https://doi.org/10.1016/j.arth.2023.08.025

Vancouver

Parilla FW, Youngman TR, Layon DR, Ince DC, Pashos GE, Maloney WJ, et al. Excellent 20-Year Results of Total Hip Arthroplasty With Highly Cross-Linked Polyethylene on Cobalt-Chromium Femoral Heads in Patients ≤50 Years. The Journal of Arthroplasty. 2024;39(2):409-415. doi:10.1016/j.arth.2023.08.025

BibTeX
@article{Parilla2024,
  author = {Parilla, Frank W and Youngman, Tyler R and Layon, Daniel R and Ince, Deniz C and Pashos, Gail E and Maloney, William J and Clohisy, John C},
  title = {Excellent 20-Year Results of Total Hip Arthroplasty With Highly Cross-Linked Polyethylene on Cobalt-Chromium Femoral Heads in Patients ≤50 Years},
  journal = {The Journal of Arthroplasty},
  year = {2024},
  volume = {39},
  number = {2},
  pages = {409--415},
  doi = {10.1016/j.arth.2023.08.025}
}
Kostenlos starten →