EUVIMEDEUVIMED entdecken
Crossref

Novel Use of an Accelerometer to Assess Load Asymmetry Over Time After Hip Resurfacing Arthroplasty

Renee Ren, Jonathan Spaan, Andrew Jordan, Alexander Shafiro, Edwin P Su

The Journal of Arthroplasty · 2023-07 · 38 (7) · S58-S64

DOI: 10.1016/j.arth.2023.04.015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2023-07. Verfasst von Renee Ren und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York. Hauptthemen laut MEDLINE: Anterior Cruciate Ligament Injuries, Arthroplasty, Replacement, Hip, Sports. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 58 Literaturangaben. Gefördert von: American Association of Hip and Knee Surgeons.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: There is limited knowledge regarding usage of wearable technology to guide return to sport after hip resurfacing arthroplasty (HRA). This study evaluated the use of accelerometers to identify when symmetry is restored between operative and nonoperative limbs. METHODS: A total of 26 primary HRA patients performed 5 validated physical tests before, 3 and 6 months after HRA: broad jump, double-leg vertical jump (DLVJ), hop test, lateral single-leg jump (LSLJ), and vertical single-leg jump. Impact load and average intensity data (g-force units) were collected using accelerometers. Strength data (pounds [lbs.]) for internal and external rotation were collected with a dynamometer. Univariate and correlation analyses analyzed interlimb asymmetries. RESULTS: At preoperation, there were significant impact load asymmetries for DLVJ (P = .008), hop test (P = .021), and LSLJ (P = .003) and intensity asymmetry for DLVJ (P = .010) and LSLJ (P = .003). At 3 months, there was impact load asymmetry for DLVJ (P = .005) and LSLJ (P = .005) and intensity asymmetry for broad jump (P = .020), hop test (P = .042), and LSLJ (P = .005). There were significant strength asymmetries at preoperation and 3 months postoperation for internal (P = .013) and external rotation (P = .037). All significant asymmetries indicated the nonoperative leg had greater output. No significant asymmetries were found for any exercises at 6 months postoperation. An increase in Harris Hip Score was significantly associated with a decrease in impact asymmetry (rs = -0.269, P = .006). CONCLUSION: Impact loads and strength reach interlimb symmetry at 6 months post-HRA. Wearable accelerometers provide useful metrics to distinguish limb asymmetries for recovery monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anterior Cruciate Ligament InjuriesArthroplasty, Replacement, HipSportsHumansLower ExtremityAccelerometry

Stichwörter der Autor:innen

accelerometerhip resurfacing arthroplastylimb asymmetryreturn-to-sportwearable technology

Autor:innen und Institutionen

  • Division of Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York.

Förderung

  • American Association of Hip and Knee Surgeons

Zitieren

APA

Ren, R., Spaan, J., Jordan, A., Shafiro, A., & Su, E. P. (2023). Novel Use of an Accelerometer to Assess Load Asymmetry Over Time After Hip Resurfacing Arthroplasty. The Journal of Arthroplasty, 38(7), S58-S64. https://doi.org/10.1016/j.arth.2023.04.015

Vancouver

Ren R, Spaan J, Jordan A, Shafiro A, Su EP. Novel Use of an Accelerometer to Assess Load Asymmetry Over Time After Hip Resurfacing Arthroplasty. The Journal of Arthroplasty. 2023;38(7):S58-S64. doi:10.1016/j.arth.2023.04.015

BibTeX
@article{Ren2023,
  author = {Ren, Renee and Spaan, Jonathan and Jordan, Andrew and Shafiro, Alexander and Su, Edwin P},
  title = {Novel Use of an Accelerometer to Assess Load Asymmetry Over Time After Hip Resurfacing Arthroplasty},
  journal = {The Journal of Arthroplasty},
  year = {2023},
  volume = {38},
  number = {7},
  pages = {S58--S64},
  doi = {10.1016/j.arth.2023.04.015}
}
Kostenlos starten →