Extensively Porous-Coated Stems Demonstrate Excellent Long-Term Survivorship in Revision Total Hip Arthroplasty
The Journal of Arthroplasty · 2023
DOI: 10.1016/j.arth.2023.03.004 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Arthroplasty, 2023. Verfasst von Louis Dagneaux und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Hip Prosthesis, Periprosthetic Fractures. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAMS NIH HHS, NHLBI NIH HHS, American Association of Hip and Knee Surgeons.
Abstract (Originalsprache)
BACKGROUND: Extensively porous-coated cylindrical stems have demonstrated excellent results in revision total hip arthroplasties (THAs). However, most studies are midterm follow-ups and of modest cohort size. This study aimed to evaluate long-term outcomes of a large series of extensively porous-coated stems. METHODS: From 1992 to 2003, 925 extensively porous-coated stems were utilized in revision THAs at a single institution. The mean age was 65 years, and 57% of patients were males. Harris hip scores were calculated, and clinical outcomes were assessed. Radiographic assessment for stem fixation was categorized as either in-grown, fibrous stable, or loose according to Engh criteria. Risk analysis used Cox proportional hazard method. The mean follow-up was 13 years. RESULTS: Mean Harris hip scores improved from 56 to 80 at the last follow-up (P < .001). Fifty-three femoral stems (5%) were rerevised: 26 for aseptic loosening, 11 for stem fractures, 8 for infection, 5 for periprosthetic femoral fractures, and 3 for dislocation. Cumulative incidence of aseptic femoral loosening and femoral rerevision for any reason were 3% and 6.4% at 20 years, respectively. Nine of eleven stem fractures occurred with 10.5-13.5 mm diameters (mean 6 years). Radiographic review of unrevized stems demonstrated 94% bone-ingrown. Demographics, femoral bone loss, stem diameter, and length were not predictors of femoral rerevision. CONCLUSION: In this large series of revision THAs using a single extensively porous-coated stem design, the cumulative incidence of rerevision for aseptic femoral loosening was 3% at 20 years. These data confirm the durability of this stem in femoral revision, providing a long-term benchmark for newer uncemented revision stems. LEVEL OF EVIDENCE: Level IV, retrospective study.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
- Division of Biomedical Statistics and Informatics, Department of Health Sciences Research, Mayo Clinic, Rochester, Minnesota.
Förderung
- NIAMS NIH HHS
- NHLBI NIH HHS
- American Association of Hip and Knee Surgeons
- National Institutes of Health
- National Institute of Arthritis and Musculoskeletal and Skin Diseases
Zitieren
APA
Dagneaux, L., Sculco, P. K., Haight, H. J., Larson, D. R., Howard, J. L., Abdel, M. P., & Berry, D. J. (2023). Extensively Porous-Coated Stems Demonstrate Excellent Long-Term Survivorship in Revision Total Hip Arthroplasty. The Journal of Arthroplasty. https://doi.org/10.1016/j.arth.2023.03.004
Vancouver
Dagneaux L, Sculco PK, Haight HJ, Larson DR, Howard JL, Abdel MP, et al. Extensively Porous-Coated Stems Demonstrate Excellent Long-Term Survivorship in Revision Total Hip Arthroplasty. The Journal of Arthroplasty. 2023. doi:10.1016/j.arth.2023.03.004
BibTeX
@article{Dagneaux2023,
author = {Dagneaux, Louis and Sculco, Peter K and Haight, Holly J and Larson, Dirk R and Howard, James L and Abdel, Matthew P and Berry, Daniel J},
title = {Extensively Porous-Coated Stems Demonstrate Excellent Long-Term Survivorship in Revision Total Hip Arthroplasty},
journal = {The Journal of Arthroplasty},
year = {2023},
doi = {10.1016/j.arth.2023.03.004}
}
EUVIMED