EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Practice Patterns of Hip Flexion Assist Orthosis Use in Multiple Sclerosis: A Retrospective Community-Based Analysis

Christopher R Bhatla, Rajiv N Reebye

Archives of Rehabilitation Research and Clinical Translation · 2026-09 · 8 (3) · 100640

DOI: 10.1016/j.arrct.2026.100640 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Rehabilitation Research and Clinical Translation, 2026-09. Verfasst von Christopher R Bhatla und 1 weiteren Autor:innen. Beteiligte Einrichtung: MD Undergraduate Program, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To identify patterns of hip flexion assist orthosis (HFAO) use among ambulatory patients with multiple sclerosis (MS) and to assess factors influencing device adoption and discontinuation.

Design

Retrospective chart review.

Setting

Outpatient community physiatry clinic in New Westminster, British Columbia.

Participants

Fifty-four ambulatory patients with MS who were previously assessed for HFAO use between November 2017 and October 2023. Patients were 35-92 years old, able to participate in gait evaluation, and had documented physical examinations. Patients with nonambulatory status or missing motor strength data were excluded. Participants were categorized into groups based on HFAO outcomes: regular use, no follow-up postpurchase, discontinued use, declined HFAO, or unsuccessful HFAO assessment.

Interventions

Not applicable. Main Outcome Measures: Rates of HFAO use and discontinuation, hip flexor and knee extensor Medical Research Council (MRC) strength scores, lower-limb spasticity using the Modified Ashworth Scale (MAS), and qualitative factors associated with device adoption and nonuse.

Results

Of 54 patients assessed, 48 were recommended an HFAO. Forty obtained a device, and 19 used it regularly. Thirteen patients discontinued use after a mean of 20 months, primarily due to pain/discomfort (38%) and device bulkiness (31%). Discontinuation was associated with higher lower-limb spasticity (mean MAS 1.5 vs 0.77, P=.011). Cost was the primary barrier to adoption (75%). Most patients exhibited hip flexor weakness (MRC=1-3) and relatively preserved knee extensor strength (MRC≥3).

Conclusions

This study identifies clinical factors associated with HFAO use and discontinuation in ambulatory patients with MS, including hip flexion MRC scores of 1-3, knee extension MRC scores ≥3, and spasticity MAS scores

Schlagwörter

Stichwörter der Autor:innen

GaitHip jointMultiple sclerosisOrthotic devicesRehabilitationWalking

Autor:innen und Institutionen

  • MD Undergraduate Program, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.
  • Division of Physical Medicine and Rehabilitation, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada.
  • Division of Physical Medicine and Rehabilitation, Faculty of Medicine, University of British Columbia, Vancouver, BC, Canada.

Zitieren

APA

Bhatla, C. R., & Reebye, R. N. (2026). Practice Patterns of Hip Flexion Assist Orthosis Use in Multiple Sclerosis: A Retrospective Community-Based Analysis. Archives of Rehabilitation Research and Clinical Translation, 8(3), 100640. https://doi.org/10.1016/j.arrct.2026.100640

Vancouver

Bhatla CR, Reebye RN. Practice Patterns of Hip Flexion Assist Orthosis Use in Multiple Sclerosis: A Retrospective Community-Based Analysis. Archives of Rehabilitation Research and Clinical Translation. 2026;8(3):100640. doi:10.1016/j.arrct.2026.100640

BibTeX
@article{Bhatla2026,
  author = {Bhatla, Christopher R and Reebye, Rajiv N},
  title = {Practice Patterns of Hip Flexion Assist Orthosis Use in Multiple Sclerosis: A Retrospective Community-Based Analysis},
  journal = {Archives of Rehabilitation Research and Clinical Translation},
  year = {2026},
  volume = {8},
  number = {3},
  pages = {100640},
  doi = {10.1016/j.arrct.2026.100640}
}
Kostenlos starten →