Measurement of iridium isotopic concentration using proton-induced Coulomb excitation technique
Applied Radiation and Isotopes · 2026-10 · 236 · 112752
DOI: 10.1016/j.apradiso.2026.112752 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Radiation and Isotopes, 2026-10. Verfasst von A Biganeh und 2 weiteren Autor:innen. Beteiligte Einrichtung: Physics & Accelerators Research School, Nuclear Science and Technology Research Institute, P.O Box 14395-836, Tehran, Iran. Die Arbeit nennt 18 Literaturangaben.
Abstract (Originalsprache)
This study utilizes the Coulomb excitation technique with a Van de Graaff accelerator to precisely measure the γ-ray emissions of natural and enriched iridium samples, specifically targeting isotopes 191Ir and 193Ir. By analyzing and comparing the gamma emissions from both samples, the concentration of 191Ir in the enriched sample was accurately determined to be 88%. This non-destructive method demonstrates the reliability and precision of Coulomb excitation for isotopic analysis, offering a robust approach to isotopic quantification that is especially relevant for nuclear physics research, isotope enrichment, and radiopharmaceutical development. The results underscore the potential of this technique as a powerful tool for isotopic analysis across a range of elements with high atomic numbers, facilitating applications in industrial materials research and targeted medical therapies.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Physics & Accelerators Research School, Nuclear Science and Technology Research Institute, P.O Box 14395-836, Tehran, Iran.
- Physics & Accelerators Research School, Nuclear Science and Technology Research Institute, P.O Box 14395-836, Tehran, Iran. Electronic address: okakuee@aeoi.org.ir.
- Radiation Application Research School, Nuclear Science and Technology Research Institute, Tehran, Iran.
Zitieren
APA
Biganeh, A., Kakuee, O., & Sheibani, S. (2026). Measurement of iridium isotopic concentration using proton-induced Coulomb excitation technique. Applied Radiation and Isotopes, 236, 112752. https://doi.org/10.1016/j.apradiso.2026.112752
Vancouver
Biganeh A, Kakuee O, Sheibani S. Measurement of iridium isotopic concentration using proton-induced Coulomb excitation technique. Applied Radiation and Isotopes. 2026;236:112752. doi:10.1016/j.apradiso.2026.112752
BibTeX
@article{Biganeh2026,
author = {Biganeh, A and Kakuee, O and Sheibani, S},
title = {Measurement of iridium isotopic concentration using proton-induced Coulomb excitation technique},
journal = {Applied Radiation and Isotopes},
year = {2026},
volume = {236},
pages = {112752},
doi = {10.1016/j.apradiso.2026.112752}
}
EUVIMED