Comparación de dos oscilómetros automáticos vs el método tradicional con sonda Doppler en la determinación del índice tobillo-brazo

Rebeca Raya, Nuria Martínez, Fernando Cayuelas, Guillem Pera, Yolanda García

Atención Primaria Práctica · 2019

DOI: 10.1016/j.appr.2018.10.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Atención Primaria Práctica, 2019. Verfasst von Rebeca Raya und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Evaluar la concordancia entre dos métodos automáticos (Watch BP Office TWIN200ABI [WBP] y MESI ABPIMDD [MESI]) y el método con sonda Doppler en la medida del índice tobillo-brazo (ITB). Observacional descriptivo-transversal. Centro de atención primaria Parets del Vallès (Barcelona, España). Un total de 202 pacientes de 50-77 años en población atendida en atención primaria. Dos enfermeras experimentadas en la técnica realizaron todas las medidas. Se evaluó concordancia de ITB mediante coeficiente de correlación intraclase (CCI) y de ITB categorizado (enfermedad arterial periférica [EAP], sano y calcificación arterial [CA]) mediante índice kappa. Resultado ITB mediante los tres métodos. La concordancia del ITB de los métodos automáticos respecto a Doppler fue baja: CCI (intervalo de confianza del 95% [IC 95%]) 0,27 (0,00-0,50) para WBP y 0,20 (0,00-0,42) para MESI. La concordancia de ITB categorizado respecto a Doppler también fue baja: kappa (IC 95%) 0,33 (0,26-0,40) para WBP y 0,54 (0,47-0,62) para MESI. Se observó una sobreestimación del ITB con los métodos automáticos respecto a Doppler. Usando este último como gold standard, los métodos automáticos fueron específicos (98%) pero poco sensibles (WBP 44% y MESI 63%). Se determinó que un ITB < 1,12 (WBP) y < 1,16 (MESI) eran los mejores puntos de corte para comparar con ITB < 0,9 medido con Doppler. También hubo más incidencias con los métodos automáticos pero un ahorro del tiempo en la realización con MESI. La pobre concordancia de los métodos automáticos con Doppler hace que estos no puedan substituirlo en la determinación del ITB. Evaluate the concordance between two automatic methods (Watch BP Office TWIN200ABI [WBP] and MESI ABPIMDD [MESI]) and the method with Doppler in the measurement of the ankle brachial index (ABI). Descriptive cross-sectional study. Parets del Vallès Primary Care Center (Barcelona, Spain). Sample of 202 patients aged 50-77 years in a population attended in Primary Care. Two nurses experienced in the technique made all the measurements. ABI concordance was assessed by intraclass correlation coefficient (ICC) and categorized ABI (peripheral arterial disease [PAD], healthy and arterial calcification [CA]) using the kappa index. ABI result through the three methods. The agreement of the ABI of the two automatic methods related to Doppler was low: CCI (95% confidence interval [CI 95%]) 0.27 (0.00-0.50) for WBP and 0.20 (0.00-0.42) for MESI. The agreement of ABI categorized was low too: kappa (CI 95%) 0.33 (0.26-0.40) for WBP and 0.54 (0.47-0.62) for MESI. The automatic methods overestimated the ABI obtained with Doppler. Using Doppler as Gold Standard, the automatic methods were specific (98%) but not sensitive (WBP 44% and MESI 63%). It was determined that an ABI < 1.12 (WBP) and < 1.16 (MESI) were the best cut-off points to compare with ABI < 0.9 measured with Doppler. There were more incidences with the automatic methods but a saving of the realization time with MESI. The poor concordance of the automatic methods with Doppler means that they are not able to substitute it in the determination of the ABI.

Zitieren

APA

Raya, R., Martínez, N., Cayuelas, F., Pera, G., & García, Y. (2019). Comparación de dos oscilómetros automáticos vs el método tradicional con sonda Doppler en la determinación del índice tobillo-brazo. Atención Primaria Práctica. https://doi.org/10.1016/j.appr.2018.10.001

Vancouver

Raya R, Martínez N, Cayuelas F, Pera G, García Y. Comparación de dos oscilómetros automáticos vs el método tradicional con sonda Doppler en la determinación del índice tobillo-brazo. Atención Primaria Práctica. 2019. doi:10.1016/j.appr.2018.10.001

BibTeX
@article{Raya2019,
  author = {Raya, Rebeca and Martínez, Nuria and Cayuelas, Fernando and Pera, Guillem and García, Yolanda},
  title = {Comparación de dos oscilómetros automáticos vs el método tradicional con sonda Doppler en la determinación del índice tobillo-brazo},
  journal = {Atención Primaria Práctica},
  year = {2019},
  doi = {10.1016/j.appr.2018.10.001}
}
Kostenlos starten →