EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Investigating the thickness-effect of free-standing high aspect-ratio TiO2 nanotube layers on microwave-photoresponse using planar microwave resonators

Mahnaz Alijani, Benjamin D. Wiltshire, Hanna Sopha, Zahra Sarpanah, Jan Mistrik, Ludek Hromadko, Mohammad H. Zarifi, Jan M. Macak

Applied Materials Today · 2023-06 · 32 · 101832

DOI: 10.1016/j.apmt.2023.101832 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Materials Today, 2023-06. Verfasst von Mahnaz Alijani und 7 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministerstvo Školství, Mládeže a Tělovýchovy, Natural Sciences and Engineering Research Council of Canada, Canada Foundation for Innovation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

One-dimensional TiO2 nanotube (TNT) layers are a promising candidate for UV detection due to their distinctive anisotropic geometry which is effective for light harvesting and rapid carrier transport. Here, the photosensitivity efficiency of TNT layers with various thicknesses of 15, 50, 80, and 110 µm was utilized at a microwave frequency regime by modeling and experimentally. A planar microwave split ring resonator (PMSRR) was designed and fabricated to operate at ∼8 GHz to study TNT layers by monitoring the scattering parameter (S21) of the PMSRR under a constant UV irradiation power of ∼96.4 µW/cm2. According to the results, the 80 µm thick TNT layers demonstrated the highest resonant amplitude variation for the customized PMSRR. The change of the resonant amplitude was mainly attributed to the conductivity variation contributed by perturbation of trapped electron concentration, as the dominant factor under UV illumination, and their electromagnetic wave interaction. The main advantage of the proposed method of PMSRR for microwave photosensitivity monitoring over the conventional direct current (DC) conductivity measurements is to eliminate the effect of contact resistance between the TNT layers and metal electrodes utilizing the contactless aspect of wave interactions with the TNT layers at microwave regime to perform electrode-less measurements.

Förderung

  • Ministerstvo Školství, Mládeže a Tělovýchovy
  • Natural Sciences and Engineering Research Council of Canada
  • Canada Foundation for Innovation
  • CMC Microsystems
  • Mitacs
  • Vysoké Učení Technické v Brně

Zitieren

APA

Alijani, M., Wiltshire, B. D., Sopha, H., Sarpanah, Z., Mistrik, J., Hromadko, L., Zarifi, M. H., & Macak, J. M. (2023). Investigating the thickness-effect of free-standing high aspect-ratio TiO2 nanotube layers on microwave-photoresponse using planar microwave resonators. Applied Materials Today, 32, 101832. https://doi.org/10.1016/j.apmt.2023.101832

Vancouver

Alijani M, Wiltshire BD, Sopha H, Sarpanah Z, Mistrik J, Hromadko L, et al. Investigating the thickness-effect of free-standing high aspect-ratio TiO2 nanotube layers on microwave-photoresponse using planar microwave resonators. Applied Materials Today. 2023;32:101832. doi:10.1016/j.apmt.2023.101832

BibTeX
@article{Alijani2023,
  author = {Alijani, Mahnaz and Wiltshire, Benjamin D. and Sopha, Hanna and Sarpanah, Zahra and Mistrik, Jan and Hromadko, Ludek and Zarifi, Mohammad H. and Macak, Jan M.},
  title = {Investigating the thickness-effect of free-standing high aspect-ratio TiO2 nanotube layers on microwave-photoresponse using planar microwave resonators},
  journal = {Applied Materials Today},
  year = {2023},
  volume = {32},
  pages = {101832},
  doi = {10.1016/j.apmt.2023.101832}
}
Kostenlos starten →