More Than Just Arm Movement: Finger-Worn Accelerometers Provide a Valid and Sensitive Alternative to Wrist-Worn Accelerometers for Measuring Real-World Upper-Limb Performance in Stroke Survivors
Archives of Physical Medicine and Rehabilitation · 2026-08
DOI: 10.1016/j.apmr.2026.08.015 ↗Kurz gefasst
Fachartikel in der Zeitschrift Archives of Physical Medicine and Rehabilitation, 2026-08. Verfasst von Ramita Dhamrongsirivadh und 8 weiteren Autor:innen. Beteiligte Einrichtung: College of Information and Computer Sciences, University of Massachusetts Amherst, Amherst, MA. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Institutes of Health.
Themen: Schlaganfall
Abstract (Originalsprache)
OBJECTIVE: To investigate the clinical validity of finger-worn accelerometers for providing a comprehensive assessment of upper-limb motor performance in individuals poststroke in real-world environments, compared with wrist-worn accelerometers, and to examine how the clinimetric properties of wearable-based motor performance measures vary with the duration of patient data collection. DESIGN: Cross-sectional observational design. SETTING: Research laboratory and free-living environments. PARTICIPANTS: In total, 27 participants aged 18-80 years with ischemic or hemorrhagic stroke ≥6 months before enrollment and mild-to-moderate upper-limb impairment without severe range-of-motion restrictions were enrolled. A total of 3 participants were ineligible, and 4 withdrew, resulting in a final cohort of 20 participants (N=20). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Wearable-based motor performance measures derived from fine-hand movements, gross-arm movements, and the combination of fine-hand and gross-arm movements captured by finger-worn and wrist-worn accelerometers in naturalistic settings for 6.4±1.8 days. RESULTS: Wearable-based motor performance measures from fine-hand movements demonstrated the strongest convergent validity with standardized clinical assessments of motor capacity and performance-including the Fugl-Meyer Assessment for Upper Extremity, Wolf Motor Function Test, and Motor Activity Log-as well as the strongest known-group validity in distinguishing impairment levels and the highest test-retest reliability, followed by measures from combined and gross-arm movements. Convergent validity and test-retest reliability improved with longer monitoring durations, with 4 days being sufficient to obtain accurate and reliable upper-limb measures. CONCLUSIONS: Wearable-based motor performance measures from finger-worn accelerometers provide a more comprehensive assessment of upper-limb motor performance than those from wrist-worn accelerometers, supporting their use for real-world monitoring in individuals poststroke. Furthermore, the improvements in the clinimetric properties of wearable-based motor performance measures with longer monitoring durations highlight the importance of multiday monitoring to mitigate day-to-day variability and ensure robust assessment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Information and Computer Sciences, University of Massachusetts Amherst, Amherst, MA.
- Department of Physical Medicine and Rehabilitation, Harvard Medical School at Spaulding Rehabilitation Hospital, Boston, MA.
- College of Information and Computer Sciences, University of Massachusetts Amherst, Amherst, MA; Department of Electrical and Computer Engineering, University of Massachusetts Amherst, Amherst, MA; Department of Biomedic…
Förderung
- National Institutes of Health
Zitieren
APA
Dhamrongsirivadh, R., Pugliese, B. L., Civeriati, V., Piela, K., Fabara, E., Vergara-Diaz, G., Wang, Q. M., Bonato, P., & Lee, S. I. (2026). More Than Just Arm Movement: Finger-Worn Accelerometers Provide a Valid and Sensitive Alternative to Wrist-Worn Accelerometers for Measuring Real-World Upper-Limb Performance in Stroke Survivors. Archives of Physical Medicine and Rehabilitation. https://doi.org/10.1016/j.apmr.2026.08.015
Vancouver
Dhamrongsirivadh R, Pugliese BL, Civeriati V, Piela K, Fabara E, Vergara-Diaz G, et al. More Than Just Arm Movement: Finger-Worn Accelerometers Provide a Valid and Sensitive Alternative to Wrist-Worn Accelerometers for Measuring Real-World Upper-Limb Performance in Stroke Survivors. Archives of Physical Medicine and Rehabilitation. 2026. doi:10.1016/j.apmr.2026.08.015
BibTeX
@article{Dhamrongsirivadh2026,
author = {Dhamrongsirivadh, Ramita and Pugliese, Benito Lorenzo and Civeriati, Virginia and Piela, Kathy and Fabara, Eric and Vergara-Diaz, Gloria and Wang, Qing Mei and Bonato, Paolo and Lee, Sunghoon Ivan},
title = {More Than Just Arm Movement: Finger-Worn Accelerometers Provide a Valid and Sensitive Alternative to Wrist-Worn Accelerometers for Measuring Real-World Upper-Limb Performance in Stroke Survivors},
journal = {Archives of Physical Medicine and Rehabilitation},
year = {2026},
doi = {10.1016/j.apmr.2026.08.015}
}
EUVIMED