Defining a Universal Measurement Scale and Standardized Unit for Fine Motor Development
Archives of Physical Medicine and Rehabilitation · 2026-10 · 107 (10) · 2915-2923
DOI: 10.1016/j.apmr.2026.06.007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Archives of Physical Medicine and Rehabilitation, 2026-10. Verfasst von Bryant A Seamon und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Physical Therapy, Department of Rehabilitation Sciences, College of Health Professions, Medical University of South Carolina, Charleston,…. Hauptthemen laut MEDLINE: Motor Skills, Child Development. Die Arbeit nennt 43 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: To develop a construct specification equation (CSE) that identifies the task characteristics most strongly associated with fine motor item difficulty, establish a standardized unit, the fine motor unit (FMU), and define a universal measurement scale. STUDY DESIGN: Cross-sectional design. SETTING: General community. PARTICIPANTS: Secondary analysis of a convenience sample of children (n=637) under 71 months in Brazil. Children were excluded for musculoskeletal disorders, genetic syndromes, and congenital malformation. The average age was 21.7 months (18.6mo), and 51% were female. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Peabody Developmental Motor Scales-Second edition (PDMS-2) Grasp Scale. RESULTS: Explanatory factors with corresponding ordinal rating systems for fine motor development were created from task analysis and theory. Explanatory factors included shoulder/elbow/wrist movement, hand/fingers grasp, body position, object description, and cueing. Each item on the PDMS-2 Grasping Scale was rated across all explanatory variables. Explanatory variables had strong linear associations with previously published Rasch measurement item calibrations for the PDMS-2 Grasping Scale items. Forward stepwise linear regression tested the ability of explanatory variables to explain the variance in PDSM-2 item calibrations. Three models explained between 88% and 90% of the variance in PDMS-2 Grasping Scale item calibrations. The most parsimonious model included the shoulder/elbow/wrist movement and the hand/finger explanatory factors. This model was used as the CSE and anchored to items Grasp Reflex and Dynamic Marker Grasp. This established a standardized unit, the FMU, as 1/100th of the distance between each anchor. FMUs had a positive linear association with item calibrations (r=.93; P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Physical Therapy, Department of Rehabilitation Sciences, College of Health Professions, Medical University of South Carolina, Charleston, SC. Electronic address: seamon@musc.edu.
- Graduate College of Health Sciences, Hawai'i Pacific University, Honolulu, HI.
- Augusta Therapy Services for Children, LLC, North Augusta, SC.
- Division of Occupational Therapy, Department of Rehabilitation Sciences, College of Health Professions, Medical University of South Carolina, Charleston, SC.
Zitieren
APA
Seamon, B. A., Sears, C. L., Anderson, E., & Velozo, C. A. (2026). Defining a Universal Measurement Scale and Standardized Unit for Fine Motor Development. Archives of Physical Medicine and Rehabilitation, 107(10), 2915-2923. https://doi.org/10.1016/j.apmr.2026.06.007
Vancouver
Seamon BA, Sears CL, Anderson E, Velozo CA. Defining a Universal Measurement Scale and Standardized Unit for Fine Motor Development. Archives of Physical Medicine and Rehabilitation. 2026;107(10):2915-2923. doi:10.1016/j.apmr.2026.06.007
BibTeX
@article{Seamon2026,
author = {Seamon, Bryant A and Sears, Cynthia L and Anderson, Emily and Velozo, Craig A},
title = {Defining a Universal Measurement Scale and Standardized Unit for Fine Motor Development},
journal = {Archives of Physical Medicine and Rehabilitation},
year = {2026},
volume = {107},
number = {10},
pages = {2915--2923},
doi = {10.1016/j.apmr.2026.06.007}
}
EUVIMED