Validity, Test–Retest Reliability, and Learning Effect on the 1-Minute Sit-To-Stand Test in Individuals With Heart Failure
Archives of Physical Medicine and Rehabilitation · 2026-03 · 107 (3) · 481-487
DOI: 10.1016/j.apmr.2025.05.004 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Archives of Physical Medicine and Rehabilitation, 2026-03. Verfasst von Ngoc-Minh Nguyen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation, Faculty of Nursing and Medical Technology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, V…. Hauptthemen laut MEDLINE: Heart Failure, Exercise Test, Exercise Tolerance. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben.
Themen: Herzinsuffizienz
Abstract (Originalsprache)
OBJECTIVE: To evaluate the reliability, the minimally important difference (MID), and the learning effect of the 1-minute sit-to-stand test (1STST) in assessing functional exercise capacity in patients with heart failure (HF). DESIGN: A cross-sectional study. SETTING: Two hospitals. PARTICIPANTS: Patients with an HF (N=47) diagnosis by a cardiologist following the 2021 European Society of Cardiology HF guideline. Most participants were men (60%). Most participants had a normal body mass index (62%). All participants were classified as having New York Heart Association Functional Class II or III. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Each patient performed a 6-minute walk test (6MWT) and 2 1STSTs on 2 occasions spaced 1 month apart. Test-retest reliability between occasions was evaluated using the intraclass correlation coefficient (ICC), Bland-Altman plot analysis, and linear regression. The MID was determined using a distribution-based method. To assess the learning effect, we conducted a paired t test comparing the 2 1STSTs on each occasion, and the magnitude of the learning effect was quantified using Cohen's d. The correlation between the 1STST and 6MWT was performed to confirm validity. RESULTS: The 1STST showed good test-retest reliability (ICC=0.98, P .05). The MID was 1.1 repetitions. A learning effect of the 1STST was observed (P 0.8). The 1STST strongly correlated with the 6MWT (r=0.74, P=.01). CONCLUSIONS: The 1STST is a valid and reliable measure of functional exercise capacity in patients with HF. Because of the learning effect, this study recommended performing 2 trials to capture the true value.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Rehabilitation, Faculty of Nursing and Medical Technology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam; Institut de Recherche Experimental et Clinique (IREC), Pneumol…
- Department of Rehabilitation, Faculty of Nursing and Medical Technology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam; Rehabilitation Department, Hanoi Medical University, Hanoi, Vi…
- Department of Rehabilitation, Faculty of Nursing and Medical Technology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam; Physiotherapy-Rehabilitation Department, Gia Dinh People's Hos…
- Department of Internal Medicine, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam.
- Institut de Recherche Experimental et Clinique (IREC), Pneumology, ENT and Dermatology Pole (LUNS), Université Catholique de Louvain (UCLouvain), Brussels, Belgium; Service de Pneumologie, Cliniques Universitaires Saint…
- Research Unit in Rehabilitation Sciences, Faculty of Human Movement Sciences, Université Libre de Bruxelles (ULB), Brussels, Belgium.
Zitieren
APA
Nguyen, N. M., Le, H. T., Ngo, B. T., Truong, H. P., Reychler, G., & Deboeck, G. (2026). Validity, Test–Retest Reliability, and Learning Effect on the 1-Minute Sit-To-Stand Test in Individuals With Heart Failure. Archives of Physical Medicine and Rehabilitation, 107(3), 481-487. https://doi.org/10.1016/j.apmr.2025.05.004
Vancouver
Nguyen NM, Le HT, Ngo BT, Truong HP, Reychler G, Deboeck G. Validity, Test–Retest Reliability, and Learning Effect on the 1-Minute Sit-To-Stand Test in Individuals With Heart Failure. Archives of Physical Medicine and Rehabilitation. 2026;107(3):481-487. doi:10.1016/j.apmr.2025.05.004
BibTeX
@article{Nguyen2026,
author = {Nguyen, Ngoc-Minh and Le, Hien Thi and Ngo, Bich-Ly Thi and Truong, Hung Phi and Reychler, Gregory and Deboeck, Gael},
title = {Validity, Test–Retest Reliability, and Learning Effect on the 1-Minute Sit-To-Stand Test in Individuals With Heart Failure},
journal = {Archives of Physical Medicine and Rehabilitation},
year = {2026},
volume = {107},
number = {3},
pages = {481--487},
doi = {10.1016/j.apmr.2025.05.004}
}