Evaluating the Effectiveness of Transtibial Prosthetic Socket Shape Design Using Artificial Intelligence: A Clinical Comparison With Traditional Plaster Cast Socket Designs

Merel van der Stelt, Bo Berends, Marco Papenburg, Tom Langenhuyzen, Thomas Maal, Lars Brouwers, Guido de Jong, Ruud Leijendekkers

Archives of Physical Medicine and Rehabilitation · 2025-02 · 106 (2) · 239-246

DOI: 10.1016/j.apmr.2024.08.026 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Archives of Physical Medicine and Rehabilitation, 2025-02. Verfasst von Merel van der Stelt und 7 weiteren Autor:innen. Beteiligte Einrichtung: 3D Lab Radboudumc, Radboud University Medical Center, Nijmegen, The Netherlands. Electronic address: merel.vanderstelt@radboudumc.nl. Hauptthemen laut MEDLINE: Prosthesis Design, Artificial Intelligence, Artificial Limbs. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ZonMw.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To investigate the feasibility of creating an artificial intelligence (AI) algorithm to enhance prosthetic socket shapes for transtibial prostheses, aiming for a less operator-dependent, standardized approach. DESIGN: The study comprised 2 phases: first, developing an AI algorithm in a cross-sectional study to predict prosthetic socket shapes. Second, testing the AI-predicted digitally measured and standardized designed (DMSD) prosthetic socket against a manually measured and designed (MMD) prosthetic socket in a 2-week within-subject cross-sectional study. SETTING: The study was done at the rehabilitation department of the Radboud University Medical Center in Nijmegen, the Netherlands. PARTICIPANTS: The AI algorithm was developed using retrospective data from 116 patients from a Dutch orthopedic company, OIM Orthopedie, and tested on 10 randomly selected participants from Papenburg Orthopedie. INTERVENTIONS: Utilization of an AI algorithm to enhance the shape of a transtibial prosthetic socket. MAIN OUTCOME MEASURES: The algorithm was optimized to minimize the error in the test set. Participants' socket comfort score and fitting ratings from an independent physiotherapist and prosthetist were collected. RESULTS: Predicted prosthetic shapes deviated by 2.51 mm from the actual designs. In total, 8 of 10 DMSD and all 10 MMD-prosthetic sockets were satisfactory for home testing. Participants rated DMSD-prosthetic sockets at 7.1 ± 2.2 (n=8) and MMD-prosthetic sockets at 6.6 ± 1.2 (n=10) on average. CONCLUSIONS: The study demonstrates promising results for using an AI algorithm in prosthetic socket design, but long-term effectiveness and refinement for improved comfort and fit in more deviant cases are necessary.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prosthesis DesignArtificial IntelligenceArtificial LimbsHumansMaleFemaleCross-Sectional StudiesMiddle AgedRetrospective StudiesTibiaAlgorithmsProsthesis FittingAdultAgedNetherlandsAmputeesFeasibility Studies

Stichwörter der Autor:innen

3D printing3D scanningAIArtificial intelligenceDesignProsthetic socketStandardizedTranstibialTranstibial amputation

Autor:innen und Institutionen

  • 3D Lab Radboudumc, Radboud University Medical Center, Nijmegen, The Netherlands. Electronic address: merel.vanderstelt@radboudumc.nl.
  • 3D Lab Radboudumc, Radboud University Medical Center, Nijmegen, The Netherlands.
  • Papenburg Orthopedics, Ravenstein, The Netherlands.
  • OIM Orthopedie, Assen, The Netherlands.
  • Department of Surgery, Radboud University Medical Center, Nijmegen, The Netherlands.
  • Department of Rehabilitation, Radboud University Medical Center, Nijmegen, The Netherlands; Radboud Institute for Health Sciences, IQ Healthcare, Radboud University Medical Center, Nijmegen, The Netherlands.

Förderung

  • ZonMw

Zitieren

APA

van der Stelt, M., Berends, B., Papenburg, M., Langenhuyzen, T., Maal, T., Brouwers, L., de Jong, G., & Leijendekkers, R. (2025). Evaluating the Effectiveness of Transtibial Prosthetic Socket Shape Design Using Artificial Intelligence: A Clinical Comparison With Traditional Plaster Cast Socket Designs. Archives of Physical Medicine and Rehabilitation, 106(2), 239-246. https://doi.org/10.1016/j.apmr.2024.08.026

Vancouver

van der Stelt M, Berends B, Papenburg M, Langenhuyzen T, Maal T, Brouwers L, et al. Evaluating the Effectiveness of Transtibial Prosthetic Socket Shape Design Using Artificial Intelligence: A Clinical Comparison With Traditional Plaster Cast Socket Designs. Archives of Physical Medicine and Rehabilitation. 2025;106(2):239-246. doi:10.1016/j.apmr.2024.08.026

BibTeX
@article{vanderStelt2025,
  author = {van der Stelt, Merel and Berends, Bo and Papenburg, Marco and Langenhuyzen, Tom and Maal, Thomas and Brouwers, Lars and de Jong, Guido and Leijendekkers, Ruud},
  title = {Evaluating the Effectiveness of Transtibial Prosthetic Socket Shape Design Using Artificial Intelligence: A Clinical Comparison With Traditional Plaster Cast Socket Designs},
  journal = {Archives of Physical Medicine and Rehabilitation},
  year = {2025},
  volume = {106},
  number = {2},
  pages = {239--246},
  doi = {10.1016/j.apmr.2024.08.026}
}
Kostenlos starten →