Evaluating the Effectiveness of Transtibial Prosthetic Socket Shape Design Using Artificial Intelligence: A Clinical Comparison With Traditional Plaster Cast Socket Designs
Archives of Physical Medicine and Rehabilitation · 2025-02 · 106 (2) · 239-246
DOI: 10.1016/j.apmr.2024.08.026 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Archives of Physical Medicine and Rehabilitation, 2025-02. Verfasst von Merel van der Stelt und 7 weiteren Autor:innen. Beteiligte Einrichtung: 3D Lab Radboudumc, Radboud University Medical Center, Nijmegen, The Netherlands. Electronic address: merel.vanderstelt@radboudumc.nl. Hauptthemen laut MEDLINE: Prosthesis Design, Artificial Intelligence, Artificial Limbs. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ZonMw.
Abstract (Originalsprache)
OBJECTIVE: To investigate the feasibility of creating an artificial intelligence (AI) algorithm to enhance prosthetic socket shapes for transtibial prostheses, aiming for a less operator-dependent, standardized approach. DESIGN: The study comprised 2 phases: first, developing an AI algorithm in a cross-sectional study to predict prosthetic socket shapes. Second, testing the AI-predicted digitally measured and standardized designed (DMSD) prosthetic socket against a manually measured and designed (MMD) prosthetic socket in a 2-week within-subject cross-sectional study. SETTING: The study was done at the rehabilitation department of the Radboud University Medical Center in Nijmegen, the Netherlands. PARTICIPANTS: The AI algorithm was developed using retrospective data from 116 patients from a Dutch orthopedic company, OIM Orthopedie, and tested on 10 randomly selected participants from Papenburg Orthopedie. INTERVENTIONS: Utilization of an AI algorithm to enhance the shape of a transtibial prosthetic socket. MAIN OUTCOME MEASURES: The algorithm was optimized to minimize the error in the test set. Participants' socket comfort score and fitting ratings from an independent physiotherapist and prosthetist were collected. RESULTS: Predicted prosthetic shapes deviated by 2.51 mm from the actual designs. In total, 8 of 10 DMSD and all 10 MMD-prosthetic sockets were satisfactory for home testing. Participants rated DMSD-prosthetic sockets at 7.1 ± 2.2 (n=8) and MMD-prosthetic sockets at 6.6 ± 1.2 (n=10) on average. CONCLUSIONS: The study demonstrates promising results for using an AI algorithm in prosthetic socket design, but long-term effectiveness and refinement for improved comfort and fit in more deviant cases are necessary.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- 3D Lab Radboudumc, Radboud University Medical Center, Nijmegen, The Netherlands. Electronic address: merel.vanderstelt@radboudumc.nl.
- 3D Lab Radboudumc, Radboud University Medical Center, Nijmegen, The Netherlands.
- Papenburg Orthopedics, Ravenstein, The Netherlands.
- OIM Orthopedie, Assen, The Netherlands.
- Department of Surgery, Radboud University Medical Center, Nijmegen, The Netherlands.
- Department of Rehabilitation, Radboud University Medical Center, Nijmegen, The Netherlands; Radboud Institute for Health Sciences, IQ Healthcare, Radboud University Medical Center, Nijmegen, The Netherlands.
Förderung
- ZonMw
Zitieren
APA
van der Stelt, M., Berends, B., Papenburg, M., Langenhuyzen, T., Maal, T., Brouwers, L., de Jong, G., & Leijendekkers, R. (2025). Evaluating the Effectiveness of Transtibial Prosthetic Socket Shape Design Using Artificial Intelligence: A Clinical Comparison With Traditional Plaster Cast Socket Designs. Archives of Physical Medicine and Rehabilitation, 106(2), 239-246. https://doi.org/10.1016/j.apmr.2024.08.026
Vancouver
van der Stelt M, Berends B, Papenburg M, Langenhuyzen T, Maal T, Brouwers L, et al. Evaluating the Effectiveness of Transtibial Prosthetic Socket Shape Design Using Artificial Intelligence: A Clinical Comparison With Traditional Plaster Cast Socket Designs. Archives of Physical Medicine and Rehabilitation. 2025;106(2):239-246. doi:10.1016/j.apmr.2024.08.026
BibTeX
@article{vanderStelt2025,
author = {van der Stelt, Merel and Berends, Bo and Papenburg, Marco and Langenhuyzen, Tom and Maal, Thomas and Brouwers, Lars and de Jong, Guido and Leijendekkers, Ruud},
title = {Evaluating the Effectiveness of Transtibial Prosthetic Socket Shape Design Using Artificial Intelligence: A Clinical Comparison With Traditional Plaster Cast Socket Designs},
journal = {Archives of Physical Medicine and Rehabilitation},
year = {2025},
volume = {106},
number = {2},
pages = {239--246},
doi = {10.1016/j.apmr.2024.08.026}
}
EUVIMED