Determinants and Prediction of Transport Ventilators’ Oxygen Consumption
Air Medical Journal · 2025
DOI: 10.1016/j.amj.2025.05.010 ↗Kurz gefasst
Fachartikel in der Zeitschrift Air Medical Journal, 2025. Verfasst von Eloïse De Beaufort und 5 weiteren Autor:innen. Beteiligte Einrichtung: Université Paris Est-Créteil, Faculté de Santé, Créteil, France; Med2Lab, ALMS, Antony, France; INSERM U955, Institut Mondor de Recherche Biomédicale…. Hauptthemen laut MEDLINE: Air Ambulances, Oxygen Consumption, Ventilators, Mechanical. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
This study investigates the determinants of oxygen consumption in transport ventilators, a critical factor for patient safety, especially during long-distance transfers and in resource-limited settings. A bench study was conducted on 4 ventilators to measure oxygen consumption under various ventilation settings. The main factor influencing oxygen consumption was the bias flow, a specific flow not contributing to patient ventilation. A formula incorporating bias flow was assessed to estimate oxygen consumption. The accuracy of this formula was then compared with clinical data assessed during a long-distance air medical evacuation with mechanically ventilated patients. The high heterogeneity of oxygen consumption observed between the ventilators was mainly explained by the different levels of bias flow. The clinical experience revealed that including this parameter in the prediction may permit to improve oxygen consumption accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Université Paris Est-Créteil, Faculté de Santé, Créteil, France; Med2Lab, ALMS, Antony, France; INSERM U955, Institut Mondor de Recherche Biomédicale, Créteil, France.
- Services d'Aide Médicale Urgente de Paris, Centre Hospitalier Universitaire de Necker, Paris, France.
- Med2Lab, ALMS, Antony, France; Université d'Angers, Faculté de Santé, Vent'Lab, Angers, France.
- Université d'Angers, Faculté de Santé, Vent'Lab, Angers, France.
- Med2Lab, ALMS, Antony, France; Services d'Aide Médicale Urgente de Paris, Centre Hospitalier Universitaire de Necker, Paris, France; Centre Hospitalier Universitaire d'Angers, Département de Médecine Intensive-Réanimati…
- INSERM U955, Institut Mondor de Recherche Biomédicale, Créteil, France; Assistance Publique-Hôpitaux de Paris, CHU Henri Mondor, Service de Médecine Intensive-Réanimation, Créteil, France. Electronic address: guillaume.…
Zitieren
APA
De Beaufort, E., Hutin, A., Lesimple, A., Lamhaut, L., Richard, J. C., & Carteaux, G. (2025). Determinants and Prediction of Transport Ventilators’ Oxygen Consumption. Air Medical Journal. https://doi.org/10.1016/j.amj.2025.05.010
Vancouver
De Beaufort E, Hutin A, Lesimple A, Lamhaut L, Richard JC, Carteaux G. Determinants and Prediction of Transport Ventilators’ Oxygen Consumption. Air Medical Journal. 2025. doi:10.1016/j.amj.2025.05.010
BibTeX
@article{DeBeaufort2025,
author = {De Beaufort, Eloïse and Hutin, Alice and Lesimple, Arnaud and Lamhaut, Lionel and Richard, Jean-Christophe and Carteaux, Guillaume},
title = {Determinants and Prediction of Transport Ventilators’ Oxygen Consumption},
journal = {Air Medical Journal},
year = {2025},
doi = {10.1016/j.amj.2025.05.010}
}
EUVIMED