EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseOpen Access · CC BY-NC-ND 4.0

External validation of artificial intelligence-guided electrocardiogram (AI-ECG) in detecting asymptomatic left ventricular dysfunction: A systematic review and meta-analysis

Jacky Chen, Thomas H Marwick, Cheng Hwee Soh

American Journal of Preventive Cardiology · 2027-01 · 31 · 101691

DOI: 10.1016/j.ajpc.2026.101691 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift American Journal of Preventive Cardiology, 2027-01. Verfasst von Jacky Chen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Imaging Research Laboratory, Baker Heart and Diabetes Institute, Melbourne, Australia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Health and Medical Research Council, National Heart Foundation of Australia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

Asymptomatic left ventricular dysfunction (LVD) represents a key and frequently under-recognized stage in the heart failure (HF) continuum. Early identification enables targeted prevention and timely initiation of evidence-based therapies. Artificial intelligence-enabled electrocardiography (AI-ECG) may provide a scalable alternative to imaging for LVD detection. This systematic review synthesized evidence from exclusively externally validated AI-ECG studies evaluating the detection of asymptomatic LVD, with symptomatic HF cohorts included to contextualize the evidence base across the HF continuum.

Methods

A systematic literature search was conducted on 8th September 2025. The main output was the pooled area under the receiver operating characteristic curve (AUROC).

Results

From 3,587 records, 12 asymptomatic and 30 symptomatic studies were identified (538,735 participants). In asymptomatic cohorts evaluating left ventricular systolic dysfunction (LVSD), AI-ECG demonstrated promising but heterogeneous discriminatory performance (I²>85%) with pooled AUROCs of 0.87 (95% CI 0.75-0.99) for LVEF ≤35%, 0.93 (95% CI 0.88-0.97) for LVEF ≤40%, and 0.89 (95% CI 0.85-0.97) for LVEF ≤50%. Symptomatic cohorts showed AUROCs of 0.89 (95% CI 0.86-0.92), 0.90 (95% CI 0.88-0.92), and 0.85 (95% CI 0.83-0.86) respectively. Asymptomatic left ventricular diastolic dysfunction (LVDD) demonstrated moderate performance (AUROC 0.76, 95% CI 0.66-0.86) with no externally validated symptomatic LVDD studies identified. Small-study effects were detected exclusively in asymptomatic cohorts.

Conclusions

Discriminatory performance of AI-ECG in asymptomatic LVSD is broadly comparable to symptomatic populations. High risk of bias driven by prolonged ECG-to-echocardiogram intervals reflecting real-world logistical constraints necessitate cautious interpretation of results and further prospective validation.

Schlagwörter

Stichwörter der Autor:innen

Artificial intelligenceElectrocardiogramHeart failure

Autor:innen und Institutionen

  • Imaging Research Laboratory, Baker Heart and Diabetes Institute, Melbourne, Australia.
  • Baker Department of Cardiometabolic Health, University of Melbourne, Melbourne, Australia.
  • Menzies Institute for Medical Research, Hobart, Australia.
  • Baker Department of Cardiovascular Research, Translation and Implementation, La Trobe University, Melbourne, Australia.

Förderung

  • National Health and Medical Research Council
  • National Heart Foundation of Australia

Zitieren

APA

Chen, J., Marwick, T. H., & Soh, C. H. (2027). External validation of artificial intelligence-guided electrocardiogram (AI-ECG) in detecting asymptomatic left ventricular dysfunction: A systematic review and meta-analysis. American Journal of Preventive Cardiology, 31, 101691. https://doi.org/10.1016/j.ajpc.2026.101691

Vancouver

Chen J, Marwick TH, Soh CH. External validation of artificial intelligence-guided electrocardiogram (AI-ECG) in detecting asymptomatic left ventricular dysfunction: A systematic review and meta-analysis. American Journal of Preventive Cardiology. 2027;31:101691. doi:10.1016/j.ajpc.2026.101691

BibTeX
@article{Chen2027,
  author = {Chen, Jacky and Marwick, Thomas H and Soh, Cheng Hwee},
  title = {External validation of artificial intelligence-guided electrocardiogram (AI-ECG) in detecting asymptomatic left ventricular dysfunction: A systematic review and meta-analysis},
  journal = {American Journal of Preventive Cardiology},
  year = {2027},
  volume = {31},
  pages = {101691},
  doi = {10.1016/j.ajpc.2026.101691}
}
Kostenlos starten →