Leserbrief in der Zeitschrift American Journal of Obstetrics and Gynecology, 2023-10. Verfasst von Rebecca F Hamm und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA; Leonard Davis Institute of Health …. Hauptthemen laut MEDLINE: Pregnancy, High-Risk, Fetal Monitoring. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 5 Literaturangaben. Gefördert von: University of Pennsylvania, Institute for Translational Medicine and Therapeutics.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND The need for serial in-office non-stress tests (NSTs) adds significant burden to high-risk pregnancies and exacerbates care disparities. OBJECTIVE We sought to determine the clinical interpretability, reactivity, and usability of a self-administered, wireless pregnancy monitoring device called INVU by NuvoTM to enable patients to conduct NSTs from home. STUDY DESIGN Patients with high-risk singleton pregnancies ≥32 weeks of gestation and BMI 1) included advanced maternal age (n=14), body mass index ≥40kg/m2 (n=11), gestational diabetes, type A2 (n=10), chronic hypertension on antihypertensive medications (n=3), antiphospholipid syndrome (n=2), and other (n=9). Five consented patients failed to complete the device training. The remaining 29 patients had 131 qualifying remote NST sessions. INVUTM successfully obtained an interpretable NST in 93.9% (n=123) of appointments, of which 98.3% (n=121) were considered reactive. Patients avoided an in-office visit in 88.5% of visits. Twenty-three (79.3%) of patients who attempted at least 1 remote NST completed the SUS, with a mean score of 76.5 (± 15.9) out of 100, indicating "good" usability, with 22 (95.7%) agreeing they would prefer remote NSTs over in-office testing in a future pregnancy. CONCLUSIONS The INVUTM device showed excellent interpretability and usability for at-home NSTs in high-risk pregnancies, eliminating the need for an in-person visit in >88% of appointments. Further work is needed to determine how remote NSTs may relieve barriers to care and improve outcomes in high-risk pregnancies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pregnancy, High-RiskFetal MonitoringPregnancyFemaleHumans

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA; Leonard Davis Institute of Health Economics, University of Pennsylvania Perelman School of Medicine, Phi…
  • Nuvo Group, Ltd, Tel Aviv, Israel.
  • Department of Obstetrics and Gynecology, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA.

Förderung

  • University of Pennsylvania
  • Institute for Translational Medicine and Therapeutics

Zitieren

APA

Hamm, R. F., Shkolnik, K., Keren, N., Reches, A., Purnell, J., McCabe, M., Parry, S., & Schwartz, N. (2023). Utilization of a wireless monitoring device to perform nonstress tests in high-risk pregnancies from home. American Journal of Obstetrics and Gynecology, 229(4), 463-464. https://doi.org/10.1016/j.ajog.2023.06.012

Vancouver

Hamm RF, Shkolnik K, Keren N, Reches A, Purnell J, McCabe M, et al. Utilization of a wireless monitoring device to perform nonstress tests in high-risk pregnancies from home. American Journal of Obstetrics and Gynecology. 2023;229(4):463-464. doi:10.1016/j.ajog.2023.06.012

BibTeX
@article{Hamm2023,
  author = {Hamm, Rebecca F and Shkolnik, Ketty and Keren, Nina and Reches, Amit and Purnell, Janelle and McCabe, Meaghan and Parry, Samuel and Schwartz, Nadav},
  title = {Utilization of a wireless monitoring device to perform nonstress tests in high-risk pregnancies from home},
  journal = {American Journal of Obstetrics and Gynecology},
  year = {2023},
  volume = {229},
  number = {4},
  pages = {463--464},
  doi = {10.1016/j.ajog.2023.06.012}
}
Kostenlos starten →