Segmental torque relevant orthodontic bracket tie-wing deformation in various bracket-archwire-ligature combinations
American Journal of Orthodontics and Dentofacial Orthopedics · 2026-07 · 170 (1) · 13-22
DOI: 10.1016/j.ajodo.2026.01.022 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Orthodontics and Dentofacial Orthopedics, 2026-07. Verfasst von Subramanian Sundar und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, India. Hauptthemen laut MEDLINE: Orthodontic Brackets, Orthodontic Wires, Orthodontic Appliance Design. Die Arbeit nennt 20 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND In fixed appliance therapy, torque moments are transferred through the bracket and are important for the final position of the tooth. Studies have analyzed only the torque-relevant bracket deformation in single bracket-archwire combinations with respect to various archwire rotations, although segmental torque is often used clinically. METHODS In this study, experiments were conducted in an experimental setup with 2-bracket segments with 0.018-in and 0.022-in conventional brackets with commonly used rectangular archwires and ligatures to measure the torque moment and the relevant tie-wings deformation for 6, 7, and 8 mm interbracket distances (IBD). RESULTS The torque moment in both 0.018-in and 0.022-in brackets increased as the archwire dimension and rotation increased. The torque moment with stainless steel ligation was significantly larger than that of the elastic ligature for all the archwires tested in both brackets. Each segmental bracket-archwire-ligature-IBD combination tested had shown a significant difference between the distal and mesial tie-wing deformations for varying torque. CONCLUSIONS We conclude that in both 0.018-in and 0.022-in brackets, the behavior of the 2-bracket segment-archwire-ligature combination with varying IBD was strongly influenced by the individual factors and also in combination.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Mechanical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, India.
- Division of Orthodontics, Teeth "N" Jaws Center, Lake Area, Chennai, Tamil Nadu, India.
- Department of Mechanical Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, India. Electronic address: kingslyd@srmist.edu.in.
Zitieren
APA
Sundar, S., Harikrishnan, P., & Singh, D. K. J. (2026). Segmental torque relevant orthodontic bracket tie-wing deformation in various bracket-archwire-ligature combinations. American Journal of Orthodontics and Dentofacial Orthopedics, 170(1), 13-22. https://doi.org/10.1016/j.ajodo.2026.01.022
Vancouver
Sundar S, Harikrishnan P, Singh DKJ. Segmental torque relevant orthodontic bracket tie-wing deformation in various bracket-archwire-ligature combinations. American Journal of Orthodontics and Dentofacial Orthopedics. 2026;170(1):13-22. doi:10.1016/j.ajodo.2026.01.022
BibTeX
@article{Sundar2026,
author = {Sundar, Subramanian and Harikrishnan, Pandurangan and Singh, Devadhas Kingsly Jeba},
title = {Segmental torque relevant orthodontic bracket tie-wing deformation in various bracket-archwire-ligature combinations},
journal = {American Journal of Orthodontics and Dentofacial Orthopedics},
year = {2026},
volume = {170},
number = {1},
pages = {13--22},
doi = {10.1016/j.ajodo.2026.01.022}
}
EUVIMED