Do different orthodontic archwires alter the biomechanical effects of open coil springs on dentoalveolar structures? A finite element analysis
American Journal of Orthodontics and Dentofacial Orthopedics · 2026-06 · 169 (6) · 786-797
DOI: 10.1016/j.ajodo.2026.01.018 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Orthodontics and Dentofacial Orthopedics, 2026-06. Verfasst von Arda Demir und 2 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Orthodontics, Faculty of Dentistry, Ege University, İzmir, Turkey. Hauptthemen laut MEDLINE: Orthodontic Wires, Finite Element Analysis, Dental Stress Analysis. Die Arbeit nennt 25 Literaturangaben. Gefördert von: Ege University.
Abstract (Originalsprache)
BACKGROUND In this study, the effect of open-arch mechanics on the displacement and von Mises stress distributions in mandibular teeth was investigated using a finite element analysis. METHODS After mandibular bone, teeth, and periodontal ligament formation, 0.022-in brackets and 0.016 × 0.022-in tubes were placed on the buccal equatorial line. Four scenarios were modeled using 2 materials (nickel-titanium [NiTi] and stainless steel [SS]) and 2 arch wire sizes (0.016-in and 0.016 × 0.022-in). Displacement and von Mises stresses were analyzed via finite element analysis (Algor Fempro, ALGOR Inc, Pittsburgh, Pa) in models including teeth up to the second molar, with the mandibular left first premolar missing. RESULTS The highest von Mises stress was found in the 0.016-in NiTi wire, and the lowest in the 0.016-in SS wire. Across scenarios, peak root surface stress was at the apical region of the mandibular left second premolar, whereas the highest periodontal ligament stress was in its gingival third. The buccal tubercle of this tooth showed the greatest displacement. Among archwires, the highest stress occurred in the 0.016-in SS wire. CONCLUSIONS Von Mises stresses decreased with distance from the missing tooth site. The highest stress occurred at the apical end of the mandibular left second premolar. Except for the 0.016-in round NiTi wire, this tooth showed the greatest tubercle apex displacement. In all scenarios, except the mandibular left first molar, mesial root stresses were greater in the mandibular roots than in the distal roots.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- From the Department of Orthodontics, Faculty of Dentistry, Ege University, İzmir, Turkey.
- From the Department of Orthodontics, Faculty of Dentistry, Ege University, İzmir, Turkey. Electronic address: furkandindaroglu@yahoo.com.tr.
Förderung
- Ege University
Zitieren
APA
Demir, A., Akgün Kantar, A., & Dindaroğlu, F. (2026). Do different orthodontic archwires alter the biomechanical effects of open coil springs on dentoalveolar structures? A finite element analysis. American Journal of Orthodontics and Dentofacial Orthopedics, 169(6), 786-797. https://doi.org/10.1016/j.ajodo.2026.01.018
Vancouver
Demir A, Akgün Kantar A, Dindaroğlu F. Do different orthodontic archwires alter the biomechanical effects of open coil springs on dentoalveolar structures? A finite element analysis. American Journal of Orthodontics and Dentofacial Orthopedics. 2026;169(6):786-797. doi:10.1016/j.ajodo.2026.01.018
BibTeX
@article{Demir2026,
author = {Demir, Arda and Akgün Kantar, Ayça and Dindaroğlu, Furkan},
title = {Do different orthodontic archwires alter the biomechanical effects of open coil springs on dentoalveolar structures? A finite element analysis},
journal = {American Journal of Orthodontics and Dentofacial Orthopedics},
year = {2026},
volume = {169},
number = {6},
pages = {786--797},
doi = {10.1016/j.ajodo.2026.01.018}
}
EUVIMED