Assessment of clear aligner accuracy of 2 clear aligners systems
American Journal of Orthodontics and Dentofacial Orthopedics · 2023
DOI: 10.1016/j.ajodo.2023.05.028 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Orthodontics and Dentofacial Orthopedics, 2023. Verfasst von Mahdi Taebi Harandi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Private practice, Los Angeles, Calif. Hauptthemen laut MEDLINE: Malocclusion, Orthodontic Appliances, Removable. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: This study compared treatment efficacy for specific tooth movements between 2 clear aligner systems (Clarity [3M Oral Care Solutions, St Paul, Minn] and Invisalign [Align Technology, San Jose, Calif]). METHODS: The study sample included 47 patients (7 males, 40 females; mean age, 36.57 ± 15.97 years) treated with Invisalign and 37 (4 males, 33 females; mean age, 34.30 ± 16.35 years) treated with Clarity aligners who completed their first set of aligners and had an initial refinement scan. Initial and predicted models were obtained from the initial simulated treatment plan. The first model of the refinement scan was labeled as achieved. SlicerCMF software (version 3.1; http://www.slicer.org) was used to superimpose the achieved and predicted digital models over the initial ones with regional superimposition on the relatively stable first molars. Nine hundred forty teeth in the Invisalign system were measured for horizontal, vertical, and angular movements and transverse width and compared with similar measurements of 740 teeth for the Clarity aligners. The deviation from the predicted was calculated and compared between both systems. RESULTS: The deviation achieved from the predicted was significant between the groups for the mandibular interpremolar and intercanine widths (P 0.05). CONCLUSIONS: The efficacy of clear aligner therapy systems (Clarity and Invisalign) in treating mild and moderate malocclusions was comparable. Deviation of the achieved movements from the predicted was greatest for rotational and vertical movements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Private practice, Los Angeles, Calif.
- Department of Orthodontics, University of Florida, Gainesville, Fla. Electronic address: sabuarqub@ufl.edu.
- Division of Orthodontics, UConn Health, School of Dental Medicine, Farmington, Conn.
- Connecticut Convergence Institute for Translation in Regenerative Engineering, UConn Health, Farmington, Conn.
- Department of Developmental Sciences/Orthodontics, Marquette University School of Dentistry, Milwaukee, Wis.
- Department of Orthodontics, University of Connecticut School of Dental Medicine, Farmington, Conn.
Zitieren
APA
Harandi, M. T., Abu Arqub, S., Warren, E., Kuo, C. L., Da Cunha Godoy, L., Mehta, S., Feldman, J., Upadhyay, M., & Yadav, S. (2023). Assessment of clear aligner accuracy of 2 clear aligners systems. American Journal of Orthodontics and Dentofacial Orthopedics. https://doi.org/10.1016/j.ajodo.2023.05.028
Vancouver
Harandi MT, Abu Arqub S, Warren E, Kuo CL, Da Cunha Godoy L, Mehta S, et al. Assessment of clear aligner accuracy of 2 clear aligners systems. American Journal of Orthodontics and Dentofacial Orthopedics. 2023. doi:10.1016/j.ajodo.2023.05.028
BibTeX
@article{Harandi2023,
author = {Harandi, Mahdi Taebi and Abu Arqub, Sarah and Warren, Emma and Kuo, Chia-Ling and Da Cunha Godoy, Lucas and Mehta, Shivam and Feldman, Jonathan and Upadhyay, Madhur and Yadav, Sumit},
title = {Assessment of clear aligner accuracy of 2 clear aligners systems},
journal = {American Journal of Orthodontics and Dentofacial Orthopedics},
year = {2023},
doi = {10.1016/j.ajodo.2023.05.028}
}
EUVIMED