Biomechanical effects of clear aligners with different thicknesses and gingival-margin morphology for appliance design optimization

Xinwei Lyu, Xing Cao, Jiayin Yan, Runling Zeng, Jiali Tan

American Journal of Orthodontics and Dentofacial Orthopedics · 2023

DOI: 10.1016/j.ajodo.2022.12.014 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Orthodontics and Dentofacial Orthopedics, 2023. Verfasst von Xinwei Lyu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, Hospital of Stomatology, Sun Yat-sen University, Guangzhou, China; Guangdong Provincial Key Laboratory of Stomatology, Gu…. Hauptthemen laut MEDLINE: Incisor, Orthodontic Appliances, Removable. Die Arbeit wurde bisher 44-mal zitiert (Crossref) und nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: The objectives of this study were to investigate the biomechanical effects of clear aligners (CAs) with various thermoplastic material thicknesses and gingival-margin designs for space closure in extraction treatment and to propose a computer-aided procedure to optimize CA design. METHODS: The radiologic and intraoral scanning technology, in vitro mechanical experiment, viscoelastic modeling, and finite element analysis (FEA) were integrated to establish an orthodontic simulation model. Twelve FEA models of CA were created, comprising combinations of 2 kinds of thicknesses (0.75 and 0.50 mm), 2 forms of gingival-margin shape (scalloped and straight), and 3 types of margin height (-2, 0, and 2 mm). In vitro testing was carried out to determine the actual properties of material thickness. RESULTS: A 0.75-mm-thick aligner resulted in greater periodontal ligament (PDL) stress than 0.50 mm, and there was no clear correlation between the control ability of tooth movement and the thickness. For different margin designs, PDL stress at -2 mm height was significantly lower than those with a higher border. Aligners with straight margins had higher stress than the scalloped aligners, whereas the differences were unnoticeable at 2 mm height. The optimized aligner with differential margin designs was recommended on the basis of biomechanical calculations, which facilitated the efficiency and control of tooth movement for multiple teeth. CONCLUSIONS: The effect of material thickness and margin design of CA on the force and movement differed in different teeth. Preferable CA designs of each tooth during different movement stages should be presented personalized under the guidance of precise biomechanics instead of pure morphologic analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IncisorOrthodontic Appliances, RemovableHumansMaxillaComputer SimulationMechanical PhenomenaBiomechanical PhenomenaTooth Movement TechniquesFinite Element AnalysisOrthodontic Appliance Design

Autor:innen und Institutionen

  • Department of Orthodontics, Hospital of Stomatology, Sun Yat-sen University, Guangzhou, China; Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China; Guanghua School of Stomatology, Sun Yat-sen University…

Zitieren

APA

Lyu, X., Cao, X., Yan, J., Zeng, R., & Tan, J. (2023). Biomechanical effects of clear aligners with different thicknesses and gingival-margin morphology for appliance design optimization. American Journal of Orthodontics and Dentofacial Orthopedics. https://doi.org/10.1016/j.ajodo.2022.12.014

Vancouver

Lyu X, Cao X, Yan J, Zeng R, Tan J. Biomechanical effects of clear aligners with different thicknesses and gingival-margin morphology for appliance design optimization. American Journal of Orthodontics and Dentofacial Orthopedics. 2023. doi:10.1016/j.ajodo.2022.12.014

BibTeX
@article{Lyu2023,
  author = {Lyu, Xinwei and Cao, Xing and Yan, Jiayin and Zeng, Runling and Tan, Jiali},
  title = {Biomechanical effects of clear aligners with different thicknesses and gingival-margin morphology for appliance design optimization},
  journal = {American Journal of Orthodontics and Dentofacial Orthopedics},
  year = {2023},
  doi = {10.1016/j.ajodo.2022.12.014}
}
Kostenlos starten →