EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte Studie

Comparison of 2 different wear protocols of vacuum-formed retainers with respect to the conventional parameters and 3-dimensional superimpositional analysis

Wilka Garcia-Nunez, Grant C Vezina, Isil Aras

American Journal of Orthodontics and Dentofacial Orthopedics · 2023

DOI: 10.1016/j.ajodo.2021.09.023 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift American Journal of Orthodontics and Dentofacial Orthopedics, 2023. Verfasst von Wilka Garcia-Nunez und 2 weiteren Autor:innen. Beteiligte Einrichtung: Private Practice, Miami, Fla. Hauptthemen laut MEDLINE: Orthodontic Appliance Design, Orthodontic Retainers. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: American Association of Orthodontists Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: This study aimed to compare the effectiveness of 2 different wear protocols of vacuum-formed retainers (VFR) in terms of angular and linear displacement of teeth using 3-dimensional (3D) superimpositional analysis and conventional model parameters. METHODS: The study was conducted on 2 groups, each consisting of 17 patients randomly assigned to the part-time group or full-time group of VFR wearing after a nonextraction treatment. While conventional model measurements were assessed on 3D dental casts, 3D tooth movements were evaluated by digitally superimposed scans of casts acquired at 4-time points (debonding and 1, 3, and 6 months after debonding). Regarding conventional parameters, the difference between time-dependent changes among the groups was tested using the nonparametric Brunner-Langer and parametric linear mixed models. Considering 3D measurements, comparisons of groups were made using the Student t tests. RESULTS: There were no significant intergroup differences regarding conventional model parameters at any time (P >0.05). Significant intergroup differences were observed regarding angular and linear relapses in the labiolingual direction for maxillary and mandibular incisors, as well as the rotational relapses for maxillary left canine and mandibular right lateral incisor, which were greater in the part-time group in the first month and at the end of 6 months (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthodontic Appliance DesignOrthodontic RetainersHumansRecurrenceTooth Movement TechniquesVacuum

Autor:innen und Institutionen

  • Private Practice, Miami, Fla.
  • Private Practice, Tallahassee, Fla.
  • School of Orthodontics, Brooks Rehabilitation College of Healthcare Sciences, Jacksonville University, Jacksonville, Fla. Electronic address: iaras@ju.edu.

Förderung

  • American Association of Orthodontists Foundation

Zitieren

APA

Garcia-Nunez, W., Vezina, G. C., & Aras, I. (2023). Comparison of 2 different wear protocols of vacuum-formed retainers with respect to the conventional parameters and 3-dimensional superimpositional analysis. American Journal of Orthodontics and Dentofacial Orthopedics. https://doi.org/10.1016/j.ajodo.2021.09.023

Vancouver

Garcia-Nunez W, Vezina GC, Aras I. Comparison of 2 different wear protocols of vacuum-formed retainers with respect to the conventional parameters and 3-dimensional superimpositional analysis. American Journal of Orthodontics and Dentofacial Orthopedics. 2023. doi:10.1016/j.ajodo.2021.09.023

BibTeX
@article{GarciaNunez2023,
  author = {Garcia-Nunez, Wilka and Vezina, Grant C and Aras, Isil},
  title = {Comparison of 2 different wear protocols of vacuum-formed retainers with respect to the conventional parameters and 3-dimensional superimpositional analysis},
  journal = {American Journal of Orthodontics and Dentofacial Orthopedics},
  year = {2023},
  doi = {10.1016/j.ajodo.2021.09.023}
}
Kostenlos starten →