Saloon Door Technique – “open sky” IOL exchange utilising flanged haptic fixation behind a pre-existing Artificial Iris
American Journal of Ophthalmology Case Reports · 2025-12 · 40 · 102431
DOI: 10.1016/j.ajoc.2025.102431 ↗Kurz gefasst
Fallbericht in der Zeitschrift American Journal of Ophthalmology Case Reports, 2025-12. Verfasst von Kilian Roth und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Hospital of the Brothers of St. John of God Vienna, Johannes von Gott Platz 1, 1020, Vienna, Austria. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose: This paper introduces a novel surgical approach, the "Saloon Door Technique", which allows intraocular lens (IOL) replacement behind a pre-existing Artificial Iris (AI) without its removal. Observations: A 57-year-old patient with a history of complicated cataract surgery, AI implantation, and recurrent corneal decompensation presented with a dislocated anterior chamber IOL. To prevent further corneal decompensation, we performed an IOL exchange and penetrating keratoplasty under open-sky conditions while preserving the AI. The AI was radially incised at two opposite sites to allow the insertion of a new 3-piece IOL through the 'saloon door' into the posterior chamber. The haptics were then externalized and flanged with a Forceps Needle using a modified Yamane technique. The postoperative course was uneventful, with stable IOL positioning and a clear corneal graft at follow-up. Conclusions and importance: The Saloon Door Technique enables IOL implantation behind a pre-existing AI while preserving its integrity. By making two controlled incisions in the AI, the IOL can be carefully maneuvered through the "saloon door", followed by scleral fixation using a modified Yamane technique. This technique represents a valuable advancement in anterior segment surgery for complex cases involving AI and IOL exchange.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Hospital of the Brothers of St. John of God Vienna, Johannes von Gott Platz 1, 1020, Vienna, Austria.
- Sigmund Freud Private University Vienna, Campus Prater, Freudplatz 1+3, 1020, Vienna, Austria.
Zitieren
APA
Roth, K., Seiller-Tarbuk, K., & Amon, M. (2025). Saloon Door Technique – “open sky” IOL exchange utilising flanged haptic fixation behind a pre-existing Artificial Iris. American Journal of Ophthalmology Case Reports, 40, 102431. https://doi.org/10.1016/j.ajoc.2025.102431
Vancouver
Roth K, Seiller-Tarbuk K, Amon M. Saloon Door Technique – “open sky” IOL exchange utilising flanged haptic fixation behind a pre-existing Artificial Iris. American Journal of Ophthalmology Case Reports. 2025;40:102431. doi:10.1016/j.ajoc.2025.102431
BibTeX
@article{Roth2025,
author = {Roth, Kilian and Seiller-Tarbuk, Konstantin and Amon, Michael},
title = {Saloon Door Technique – “open sky” IOL exchange utilising flanged haptic fixation behind a pre-existing Artificial Iris},
journal = {American Journal of Ophthalmology Case Reports},
year = {2025},
volume = {40},
pages = {102431},
doi = {10.1016/j.ajoc.2025.102431}
}