EUVIMEDEUVIMED entdecken
Crossref

Impact of external female urinary catheter use on urine chemistry test results

Marco Cassone, Jessica Ameling, Lona Mody, Sanjeevkumar Patel, Nancy S Muyanja, Jennifer Meddings

American Journal of Infection Control · 2024

DOI: 10.1016/j.ajic.2024.03.010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Infection Control, 2024. Verfasst von Marco Cassone und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Geriatric and Palliative Care Medicine, Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI. Hauptthemen laut MEDLINE: Urinary Catheters. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: We aimed to evaluate how urine chemistry tests are impacted by collection using a female external urinary catheter employing wicking and suction, to assess this catheter's potential as an alternative to transurethral catheters for collecting urine samples from incontinent patients. METHODS: We obtained 50 random 40 mL refrigerated urine specimens from excess volume submitted to the Michigan Medicine Biochemical Laboratory. Specimens were split into a 10 mL "control" sample simulating voided urine, and a 30 mL paired "wicked" sample applied dropwise to and collected from a fresh PureWick system simulating collection from an incontinent patient. Each sample pair was tested for glucose, sodium, potassium, creatinine, urea, total protein, and derived ratios of sodium/creatinine, urea/creatinine, and protein/creatinine, then compared using Pearson correlation coefficients. Wicking materials were imaged via absorption contrast tomography on a laboratory X-ray microscope, to study the structure through which urine passes. RESULTS: Control and wicked urine samples had very similar results for all chemical tests evaluated: strong Pearson correlation coefficients ranging from 0.955 (potassium) to 0.997 (glucose). Microscopic assessment of the amorphous wicking materials demonstrated an average pore spacing of 95.38 µm. CONCLUSIONS: Common urine chemistry tests were unaltered by collection using the PureWick female external catheter system. This external device can be used to collect urine for chemistry tests as an alternative to transurethral catheters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Urinary CathetersHumansFemaleUrinalysisUrine Specimen CollectionUrineUrinary CatheterizationGlucoseSpecimen Handling

Stichwörter der Autor:innen

DiagnosticExternal female catheterUrinalysis

Substanzen

Glucose

Autor:innen und Institutionen

  • Division of Geriatric and Palliative Care Medicine, Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI.
  • Division of General Medicine, Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI; Patient Safety Enhancement Program, University of Michigan and VA Ann Arbor Healthcare System, Ann Arb…
  • Division of Geriatric and Palliative Care Medicine, Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI; Patient Safety Enhancement Program, University of Michigan and VA Ann Arbor Heal…
  • Medicine Service, Veterans Affairs (VA) Ann Arbor Healthcare System, Ann Arbor, MI; Division of Nephrology, Department of Internal Medicine, University of Michigan Medical School, Ann Arbor, MI.
  • Michigan Center for Materials Characterization, University of Michigan College of Engineering, Ann Arbor, MI.

Zitieren

APA

Cassone, M., Ameling, J., Mody, L., Patel, S., Muyanja, N. S., & Meddings, J. (2024). Impact of external female urinary catheter use on urine chemistry test results. American Journal of Infection Control. https://doi.org/10.1016/j.ajic.2024.03.010

Vancouver

Cassone M, Ameling J, Mody L, Patel S, Muyanja NS, Meddings J. Impact of external female urinary catheter use on urine chemistry test results. American Journal of Infection Control. 2024. doi:10.1016/j.ajic.2024.03.010

BibTeX
@article{Cassone2024,
  author = {Cassone, Marco and Ameling, Jessica and Mody, Lona and Patel, Sanjeevkumar and Muyanja, Nancy S and Meddings, Jennifer},
  title = {Impact of external female urinary catheter use on urine chemistry test results},
  journal = {American Journal of Infection Control},
  year = {2024},
  doi = {10.1016/j.ajic.2024.03.010}
}
Kostenlos starten →