EUVIMEDEUVIMED entdecken
Crossref

Investigation of the barrier performance of disposable isolation gowns

F Selcen Kilinc-Balci

American Journal of Infection Control · 2023

DOI: 10.1016/j.ajic.2023.09.003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Infection Control, 2023. Verfasst von F Selcen Kilinc-Balci. Beteiligte Einrichtung: US Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, National Personal Protective Technology Laborat…. Hauptthemen laut MEDLINE: Protective Clothing, Patient Isolation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben. Gefördert von: National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Recent epidemics and pandemics highlighted the need for effective personal protective equipment, including isolation gowns. The most critical property of an isolation gown is its ability to keep liquids and viruses from passing through the gown. Liquid and viral barrier penetration can be measured using laboratory test methods. Association for the Advancement of Medical Instrumentation (AAMI) PB70 standard defines isolation gown barrier performance levels and requirements. In this study, 22 disposable isolation gown models from 6 manufacturers were tested for liquid and viral penetration resistance. METHODS: Standard test methods were used to evaluate water and viral penetration. Test results were evaluated using AAMI PB70 barrier performance criteria for 4 protection levels. RESULTS: Seven of the 22 tested gown models did not pass liquid and viral penetration testing based on AAMI PB70 at the level claimed by the manufacturer. The majority of these failures occurred at the seam and/or tie attachment areas. CONCLUSIONS: The study findings underscore the need for improved processes surrounding activities such as premarket testing and postmarket evaluation of gowns according to standardized test methods by third-party laboratories. This study also supports the recent Food and Drug Administration guidance document that clarified the characteristics of isolation gowns considered to be class II and subject to Food and Drug Administration premarket review. Infection preventionists, hospital purchasers, and safety professionals should seek isolation gowns demonstrating conformance to industry standards from manufacturers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Protective ClothingPatient IsolationHumansPersonal Protective EquipmentDisposable Equipment

Stichwörter der Autor:innen

AAMI PB70Barrier resistanceLiquid penetrationPPEStrikethroughViral penetration

Autor:innen und Institutionen

  • US Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, PA. Electronic address: jcq8@cdc.gov.

Förderung

  • National Institute for Occupational Safety and Health
  • Centers for Disease Control and Prevention

Zitieren

APA

Kilinc-Balci, F. S. (2023). Investigation of the barrier performance of disposable isolation gowns. American Journal of Infection Control. https://doi.org/10.1016/j.ajic.2023.09.003

Vancouver

Kilinc-Balci FS. Investigation of the barrier performance of disposable isolation gowns. American Journal of Infection Control. 2023. doi:10.1016/j.ajic.2023.09.003

BibTeX
@article{KilincBalci2023,
  author = {Kilinc-Balci, F Selcen},
  title = {Investigation of the barrier performance of disposable isolation gowns},
  journal = {American Journal of Infection Control},
  year = {2023},
  doi = {10.1016/j.ajic.2023.09.003}
}