EUVIMEDEUVIMED entdecken
Crossref

Fewer emergency department alarms is associated with reduced use of medications for acute agitation

Andy Hung-Yi Lee, Patrick P Lowe, Jane M Hayes, Martin S Copenhaver, Rebecca E Cash, Maria Aristizabal, Yosef Berlyand, Joshua J Baugh, Lauren M Nentwich, Wendy L Macias-Konstantopoulos, Ali S Raja, Jonathan D Sonis

The American Journal of Emergency Medicine · 2024

DOI: 10.1016/j.ajem.2024.04.021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The American Journal of Emergency Medicine, 2024. Verfasst von Andy Hung-Yi Lee und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Massachusetts General Hospital, 55 Fruit St., Boston, MA, USA; Harvard Medical School, 25 Shattuck St., Boston, MA,…. Hauptthemen laut MEDLINE: Emergency Service, Hospital, Clinical Alarms, Psychomotor Agitation. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND AND OBJECTIVES: Patient monitoring systems provide critical information but often produce loud, frequent alarms that worsen patient agitation and stress. This may increase the use of physical and chemical restraints with implications for patient morbidity and autonomy. This study analyzes how augmenting alarm thresholds affects the proportion of alarm-free time and the frequency of medications administered to treat acute agitation. METHODS: Our emergency department's patient monitoring system was modified on June 28, 2022 to increase the tachycardia alarm threshold from 130 to 150 and to remove alarm sounds for several arrhythmias, including bigeminy and premature ventricular beats. A pre-post study was performed lasting 55 days before and 55 days after this intervention. The primary outcome was change in number of daily patient alarms. The secondary outcomes were alarm-free time per day and median number of antipsychotic and benzodiazepine medications administered per day. The safety outcome was the median number of patients transferred daily to the resuscitation area. We used quantile regression to compare outcomes between the pre- and post-intervention period and linear regression to correlate alarm-free time with the number of sedating medications administered. RESULTS: Between the pre- and post-intervention period, the median number of alarms per day decreased from 1332 to 845 (-37%). This was primarily driven by reduced low-priority arrhythmia alarms from 262 to 21 (-92%), while the median daily census was unchanged (33 vs 32). Median hours per day free from alarms increased from 1.0 to 2.4 (difference 1.4, 95% CI 0.8-2.1). The median number of sedating medications administered per day decreased from 14 to 10 (difference - 4, 95% CI -1 to -7) while the number of escalations in level of care to our resuscitation care area did not change significantly. Multivariable linear regression showed a 60-min increase of alarm-free time per day was associated with 0.8 (95% CI 0.1-1.4) fewer administrations of sedating medication while an additional patient on the behavioral health census was associated with 0.5 (95% CI 0.0-1.1) more administrations of sedating medication. CONCLUSION: A reasonable change in alarm parameter settings may increase the time patients and healthcare workers spend in the emergency department without alarm noise, which in this study was associated with fewer doses of sedating medications administered.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Emergency Service, HospitalClinical AlarmsPsychomotor AgitationHumansMaleFemaleMiddle AgedAntipsychotic AgentsAdultAgedBenzodiazepinesMonitoring, PhysiologicHypnotics and Sedatives

Stichwörter der Autor:innen

AgitationAlarmsCardiac monitoring

Substanzen

Antipsychotic AgentsBenzodiazepinesHypnotics and Sedatives

Autor:innen und Institutionen

  • Department of Emergency Medicine, Massachusetts General Hospital, 55 Fruit St., Boston, MA, USA; Harvard Medical School, 25 Shattuck St., Boston, MA, USA; Department of Emergency Medicine, UCLA David Geffen School of Me…
  • Department of Emergency Medicine, Massachusetts General Hospital, 55 Fruit St., Boston, MA, USA; Harvard Medical School, 25 Shattuck St., Boston, MA, USA.
  • Harvard Medical School, 25 Shattuck St., Boston, MA, USA; Healthcare Systems Engineering, Massachusetts General Hospital, 55 Fruit St., Boston, MA, USA.
  • Department of Emergency Medicine, Massachusetts General Hospital, 55 Fruit St., Boston, MA, USA.
  • Department of Emergency Medicine, Massachusetts General Hospital, 55 Fruit St., Boston, MA, USA; Harvard Medical School, 25 Shattuck St., Boston, MA, USA; Department of Emergency Medicine, The Warren Alpert Medical Scho…

Zitieren

APA

Lee, A. H., Lowe, P. P., Hayes, J. M., Copenhaver, M. S., Cash, R. E., Aristizabal, M., Berlyand, Y., Baugh, J. J., Nentwich, L. M., Macias-Konstantopoulos, W. L., Raja, A. S., & Sonis, J. D. (2024). Fewer emergency department alarms is associated with reduced use of medications for acute agitation. The American Journal of Emergency Medicine. https://doi.org/10.1016/j.ajem.2024.04.021

Vancouver

Lee AH, Lowe PP, Hayes JM, Copenhaver MS, Cash RE, Aristizabal M, et al. Fewer emergency department alarms is associated with reduced use of medications for acute agitation. The American Journal of Emergency Medicine. 2024. doi:10.1016/j.ajem.2024.04.021

BibTeX
@article{Lee2024,
  author = {Lee, Andy Hung-Yi and Lowe, Patrick P and Hayes, Jane M and Copenhaver, Martin S and Cash, Rebecca E and Aristizabal, Maria and Berlyand, Yosef and Baugh, Joshua J and Nentwich, Lauren M and Macias-Konstantopoulos, Wendy L and Raja, Ali S and Sonis, Jonathan D},
  title = {Fewer emergency department alarms is associated with reduced use of medications for acute agitation},
  journal = {The American Journal of Emergency Medicine},
  year = {2024},
  doi = {10.1016/j.ajem.2024.04.021}
}
Kostenlos starten →