EUVIMEDEUVIMED entdecken
Crossref

D-dimer measurement is useful irrespective of time from the onset of acute aortic syndrome symptoms

Takayuki Otani, Toshikazu Abe, Toshihisa Ichiba, Kenichiro Kashiwa, Hiroshi Naito

The American Journal of Emergency Medicine · 2023

DOI: 10.1016/j.ajem.2023.05.044 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The American Journal of Emergency Medicine, 2023. Verfasst von Takayuki Otani und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Hiroshima City Hiroshima Citizens Hospital, 7-33 Motomachi, Naka-ku, Hiroshima-city, Hiroshima 730-8518, Japan. Ele…. Hauptthemen laut MEDLINE: Aortic Dissection, Acute Aortic Syndrome. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: In acute aortic syndrome (AAS) screening, D-dimer is a well-established biomarker whose usefulness has been scarcely studied with respect to its measurement timing. We aimed to evaluate the effectiveness of D-dimer-based AAS screening focused on the time interval between AAS onset and D-dimer measurement. METHODS: We retrospectively analyzed consecutive patients diagnosed with AAS who visited our hospital between 2011 and 2021. For the primary analysis, we divided patients according to the quartiles of the time interval between AAS symptom onset and D-dimer measurement. D-dimer level ≥ 0.5 μg/mL and age-adjusted D-dimer ≥ [age (years) × 0.01] μg/mL (minimum of 0.5 μg/mL) were defined as positive. The primary endpoint was the comparative ability of D-dimer to detect AAS within and between each time quartile. In an exploratory secondary analysis, we reported patient and AAS characteristics in the subgroup of patients who underwent repeat D-dimer measurement within 48 h of the first D-dimer measure. RESULTS: The 273 AAS patients were divided into four groups based on quartiles of the time interval (Group 1, ≤1 h; Group 2, 1-2 h; Group 3, 2-5 h; and Group 4, >5 h). There were no significant differences in D-dimer levels or in the proportions with positive D-dimer (Group 1: 97%, Group 2: 96%, Group 3: 99%, Group 4: 99%; P = 0.76) or positive age-adjusted D-dimer (Group 1: 96%, Group 2: 90%, Group 3: 96%, Group 4: 97%; P = 0.32) between the groups. Of the 147 patients who had D-dimer re-measured, nine had negative D-dimer levels on either the primary or secondary measurement. Of these nine patients, eight had AAS with a thrombosed false lumen and one with a patent false lumen had a short length of dissection. In all nine patients, D-dimer levels remained low (maximum of 1.4 μg/mL). CONCLUSION: D-dimer levels were elevated from the early stages of AAS. The clinical utility of D-dimer is not affected by the time interval from AAS onset to D-dimer measurement, but rather is influenced by AAS characteristics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic DissectionAcute Aortic SyndromeHumansRetrospective StudiesFibrin Fibrinogen Degradation ProductsBiomarkers

Stichwörter der Autor:innen

Acute aortic dissectionAcute aortic syndromesAge-adjusted D-dimerBiomarkerD-dimer

Substanzen

fibrin fragment DFibrin Fibrinogen Degradation ProductsBiomarkers

Autor:innen und Institutionen

  • Department of Emergency Medicine, Hiroshima City Hiroshima Citizens Hospital, 7-33 Motomachi, Naka-ku, Hiroshima-city, Hiroshima 730-8518, Japan. Electronic address: sonnyboy@tempo.ocn.ne.jp.
  • Department of Emergency and Critical Care Medicine, Tsukuba Memorial Hospital, 1187-299 Kaname, Tsukuba, Ibaraki 300-2622, Japan; Department of Health Services Research, Faculty of Medicine, University of Tsukuba, 1-1-1…
  • Department of Emergency Medicine, Hiroshima City Hiroshima Citizens Hospital, 7-33 Motomachi, Naka-ku, Hiroshima-city, Hiroshima 730-8518, Japan.

Zitieren

APA

Otani, T., Abe, T., Ichiba, T., Kashiwa, K., & Naito, H. (2023). D-dimer measurement is useful irrespective of time from the onset of acute aortic syndrome symptoms. The American Journal of Emergency Medicine. https://doi.org/10.1016/j.ajem.2023.05.044

Vancouver

Otani T, Abe T, Ichiba T, Kashiwa K, Naito H. D-dimer measurement is useful irrespective of time from the onset of acute aortic syndrome symptoms. The American Journal of Emergency Medicine. 2023. doi:10.1016/j.ajem.2023.05.044

BibTeX
@article{Otani2023,
  author = {Otani, Takayuki and Abe, Toshikazu and Ichiba, Toshihisa and Kashiwa, Kenichiro and Naito, Hiroshi},
  title = {D-dimer measurement is useful irrespective of time from the onset of acute aortic syndrome symptoms},
  journal = {The American Journal of Emergency Medicine},
  year = {2023},
  doi = {10.1016/j.ajem.2023.05.044}
}
Kostenlos starten →