Variation of perfusion index to evaluate fluid responsiveness during the preload challenge tests: a systematic review and meta-analysis
Annals of Intensive Care · 2026 · 16 · 100136
DOI: 10.1016/j.aicoj.2026.100136 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Annals of Intensive Care, 2026. Verfasst von Haijun Huang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency, The First Affiliated Hospital of Zhejiang Chinese Medical University/Zhejiang Provincial Hospital of Chinese Medicine, Zheji…. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Major Scientific and Technological Project of Zhejiang Province.
Abstract (Originalsprache)
Background
The ability of perfusion index (PI) for predicting fluid responsiveness has been extensively studied with conflicting results. This meta-analysis evaluated the value of variation of PI (ΔPI) for predicting fluid responsiveness in adult patients undergoing preload challenge tests.
Methods
PubMed, Embase, and Cochrane Library were searched up to 20th July 2026. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and area under the summary receiver operator characteristic curve (AUROC) were calculated. Q test and I2 statistics were used for study heterogeneity and publication bias was assessed by Deeks' funnel plot asymmetry test. Subgroup analysis was performed for the potential causes of heterogeneity arising from varied patient characteristics.
Results
Overall, nine studies including 492 preload challenge tests were administered to 419 patients in this review, of whom 52% were fluid responsive. The cutoff values of ΔPI were increased between 1.024% and 33% or decreased between -7% and -40%. Pooled sensitivity and specificity were 0.79 (95% CI: 0.71-0.85) and 0.82 (95% CI: 0.75-0.87), respectively. DOR was 17 (95% CI: 10-30) and AUROC was 0.88 (95% CI: 0.85-0.90), indicating good diagnostic accuracy. Heterogeneity was low (I 2 = 28.95%, P = 0.124). Subgroup analysis showed that ΔPI performed consistently across ICU and operating room settings, regardless of preload challenge type, PI device, or ventilation status.
Conclusions
Our meta-analysis suggests that ΔPI may serve as a promising adjunct non-invasive marker for predicting fluid responsiveness during preload challenge tests, but the current evidence base remains limited, heterogeneous, and at risk of bias.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Emergency, The First Affiliated Hospital of Zhejiang Chinese Medical University/Zhejiang Provincial Hospital of Chinese Medicine, Zhejiang 310018, Hangzhou, China.
- Department of Intensive Care Unit, The First Affiliated Hospital of Zhejiang Chinese Medical University/Zhejiang Provincial Hospital of Chinese Medicine, Zhejiang 310018, Hangzhou, China.
Förderung
- Major Scientific and Technological Project of Zhejiang Province
Zitieren
APA
Huang, H., Liu, L., Feng, T., Shen, Q., Xu, H., & Wu, J. (2026). Variation of perfusion index to evaluate fluid responsiveness during the preload challenge tests: a systematic review and meta-analysis. Annals of Intensive Care, 16, 100136. https://doi.org/10.1016/j.aicoj.2026.100136
Vancouver
Huang H, Liu L, Feng T, Shen Q, Xu H, Wu J. Variation of perfusion index to evaluate fluid responsiveness during the preload challenge tests: a systematic review and meta-analysis. Annals of Intensive Care. 2026;16:100136. doi:10.1016/j.aicoj.2026.100136
BibTeX
@article{Huang2026,
author = {Huang, Haijun and Liu, Linqing and Feng, Tongfei and Shen, Qinkang and Xu, Hua and Wu, Jiannong},
title = {Variation of perfusion index to evaluate fluid responsiveness during the preload challenge tests: a systematic review and meta-analysis},
journal = {Annals of Intensive Care},
year = {2026},
volume = {16},
pages = {100136},
doi = {10.1016/j.aicoj.2026.100136}
}
EUVIMED