EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Reliability and validity of a simple smartphone-based method for assessing lower-limb function using sit-to-stand acceleration in older adults

Naofumi Yamamoto, Akiyo Higashionna, Korin Tateoka, Kazuto Noguchi

Archives of Gerontology and Geriatrics Plus · 2026-12 · 3 (4) · 100343

DOI: 10.1016/j.aggp.2026.100343 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Gerontology and Geriatrics Plus, 2026-12. Verfasst von Naofumi Yamamoto und 3 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

This study estimated trial-to-trial and device-to-device reliability of a simple smartphone web application for measuring sit-to-stand acceleration index without body attachment in older adults and assessed its validity via associations with lower-limb performance tests.

Methods

Eighty-five older adults (30 men and 55 women; mean age, 74.3 ± 5.3 years) performed a sit-to-stand movement from a 40-cm-high chair while holding a smartphone against their chest. Peak resultant acceleration (PRA), derived from triaxial acceleration (including gravity), was calculated using a smartphone-based web application. Trial-to-trial reliability was assessed from two trials with the same device (n = 85). Device-to-device reliability was evaluated through simultaneous measurements using an iPhone and four Android devices (n = 51). Validity was examined using correlations between PRA and peak ground reaction force (PGRF) during sit-to-stand, knee extension strength, and the Timed Up-and-Go test (n = 85).

Results

The intraclass correlation coefficients were 0.780 for trial-to-trial reliability and 0.925–0.974 for device-to-device reliability relative to the iPhone. Bland–Altman analysis showed mean differences ranging from −0.047 to 0.557 m/s 2 , with 95% limits of agreement ranging from −1.709 to 2.108 m/s 2 . Proportional bias occurred for one device compared with the iPhone. PRA was correlated with three lower-limb performance measures, with PGRF demonstrating the highest absolute correlation coefficient (r = 0.687, 95% confidence interval, 0.555–0.785).

Conclusions

PRA demonstrated good trial-to-trial reliability and high device-to-device reliability. In addition, the associations between PRA and established lower-limb performance measures suggest that PRA may reflect certain aspects of lower-limb performance in older adults.

Zitieren

APA

Yamamoto, N., Higashionna, A., Tateoka, K., & Noguchi, K. (2026). Reliability and validity of a simple smartphone-based method for assessing lower-limb function using sit-to-stand acceleration in older adults. Archives of Gerontology and Geriatrics Plus, 3(4), 100343. https://doi.org/10.1016/j.aggp.2026.100343

Vancouver

Yamamoto N, Higashionna A, Tateoka K, Noguchi K. Reliability and validity of a simple smartphone-based method for assessing lower-limb function using sit-to-stand acceleration in older adults. Archives of Gerontology and Geriatrics Plus. 2026;3(4):100343. doi:10.1016/j.aggp.2026.100343

BibTeX
@article{Yamamoto2026,
  author = {Yamamoto, Naofumi and Higashionna, Akiyo and Tateoka, Korin and Noguchi, Kazuto},
  title = {Reliability and validity of a simple smartphone-based method for assessing lower-limb function using sit-to-stand acceleration in older adults},
  journal = {Archives of Gerontology and Geriatrics Plus},
  year = {2026},
  volume = {3},
  number = {4},
  pages = {100343},
  doi = {10.1016/j.aggp.2026.100343}
}
Kostenlos starten →