Discordance between quantitative ultrasound and dual-energy X-ray absorptiometry in bone mineral density: The Vietnam Osteoporosis Study
Osteoporosis and Sarcopenia · 2021-03 · 7 (1) · 6-10
DOI: 10.1016/j.afos.2021.03.003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Osteoporosis and Sarcopenia, 2021-03. Verfasst von Huy G Nguyen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Bone and Muscle Research Group, Ton Duc Thang University, Ho Chi Minh City, Viet Nam. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
OBJECTIVES: Calcaneal quantitative ultrasound measurement (QUS) has been considered an alternative to dual-energy X-ray absorptiometry (DXA) based bone mineral density (BMD) for assessing bone health. This study sought to examine the utility of QUS as an osteoporosis screening tool by evaluating the correlation between QUS and DXA. METHODS: The study was a part of the Vietnam Osteoporosis Study that involved 1270 women and 773 men aged 18 years and older. BMD at the femoral neck, total hip and lumbar spine was measured using DXA. Osteoporosis was diagnosed based on the femoral neck T-score using World Health Organization criteria. Broadband ultrasound attenuation (BUA) at the calcaneus was measured by QUS. The concordance between BUA and BMD was analyzed by the linear regression model. RESULTS: In all individuals, BUA modestly correlated with femoral neck BMD (r = 0.35; P < 0.0001) and lumbar spine BMD (r = 0.34; P < 0.0001) in both men and women. In individuals aged 50 years and older, approximately 16% (n = 92/575) of women and 3.2% (n = 10/314) of men were diagnosed to have osteoporosis. Only 0.9% (n = 5/575) women and 1.0% (n = 3/314) men were classified as "Low BUA". The kappa coefficient of concordance between BMD and BUA classification was 0.09 (95% CI, 0.04 to 0.15) for women and 0.12 (95% CI, 0.03 to 0.22) for men. CONCLUSIONS: In this population-based study, QUS BUA modestly correlated with DXA BMD, suggesting that BUA is not a reliable method for screening of osteoporosis.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Bone and Muscle Research Group, Ton Duc Thang University, Ho Chi Minh City, Viet Nam.
- Faculty of Applied Sciences, Ton Duc Thang University, Ho Chi Minh City, Viet Nam.
- Garvan Institute of Medical Research, Sydney, Australia.
- School of Biomedical Engineering, University of Technology Sydney, Sydney, Australia.
Zitieren
APA
Nguyen, H. G., Lieu, K. B., Ho-Le, T. P., Ho-Pham, L. T., & Nguyen, T. V. (2021). Discordance between quantitative ultrasound and dual-energy X-ray absorptiometry in bone mineral density: The Vietnam Osteoporosis Study. Osteoporosis and Sarcopenia, 7(1), 6-10. https://doi.org/10.1016/j.afos.2021.03.003
Vancouver
Nguyen HG, Lieu KB, Ho-Le TP, Ho-Pham LT, Nguyen TV. Discordance between quantitative ultrasound and dual-energy X-ray absorptiometry in bone mineral density: The Vietnam Osteoporosis Study. Osteoporosis and Sarcopenia. 2021;7(1):6-10. doi:10.1016/j.afos.2021.03.003
BibTeX
@article{Nguyen2021,
author = {Nguyen, Huy G and Lieu, Khanh B and Ho-Le, Thao P and Ho-Pham, Lan T and Nguyen, Tuan V},
title = {Discordance between quantitative ultrasound and dual-energy X-ray absorptiometry in bone mineral density: The Vietnam Osteoporosis Study},
journal = {Osteoporosis and Sarcopenia},
year = {2021},
volume = {7},
number = {1},
pages = {6--10},
doi = {10.1016/j.afos.2021.03.003}
}