Pooled granulocyte component–a worthy rival to the apheresis product?
Advances in Medical Sciences · 2026-03 · 71 (1) · 27-39
DOI: 10.1016/j.advms.2026.01.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Advances in Medical Sciences, 2026-03. Verfasst von Artur Szumowski und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hematology, Internal Medicine and Angiology with Hematopoietic Cell Transplantation Unit, Medical University of Bialystok, Bialystok, P…. Hauptthemen laut MEDLINE: Granulocytes, Leukapheresis, Blood Component Removal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 62 Literaturangaben. Gefördert von: Uniwersytet Medyczny w Białymstoku, Medical University of Bialystok.
Abstract (Originalsprache)
PURPOSE: Granulocyte concentrates (GCs) are crucial in preventing and treating hazardous infections in neutropenic patients with hematological malignancies. Our study goal was to evaluate the impact of various collection and preparation methods on the quality of GCs. MATERIALS AND METHODS: Our study included 30 GCs that were collected either by leukapheresis (group L), by standard buffy coat pooling (group S), or by using the Reveos system (group R). All studied GCs were irradiated with gamma rays and stored for 24 h at room temperature without agitation. Laboratory tests included the assessment of leukocyte (WBC), neutrophil, lymphocyte and monocyte counts, pH, cell viability, phagocytosis, and the expression of CD11b, CD62L, CD66b and CXCR4 molecules. RESULTS: We showed that GCs prepared using different methods differed primarily in terms of cell counts, cell viability, and the CD11b, CD62L and CXCR4 expression. We also observed that gamma irradiation expectedly reduced the lymphocyte count, whereas 24-h storage drastically reduced cell viability. An additional effect of the preparation method on GCs susceptibility to quality changes due to gamma rays and 24-h storage was noticed as well. CONCLUSIONS: Our research indicates that apheresis-derived granulocytes and pooled GCs do not differ enough to not consider more frequent use of the latter in daily clinical practice. Moreover, we concluded that gamma irradiation does not worsen the quality of granulocyte components, and freshly collected GCs should be preferred.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Hematology, Internal Medicine and Angiology with Hematopoietic Cell Transplantation Unit, Medical University of Bialystok, Bialystok, Poland; Regional Centre for Transfusion Medicine in Bialystok, Bialysto…
- Regional Centre for Transfusion Medicine in Bialystok, Bialystok, Poland.
- Medical University of Bialystok Clinical Hospital, Bialystok, Poland.
Förderung
- Uniwersytet Medyczny w Białymstoku
- Medical University of Bialystok
Zitieren
APA
Szumowski, A., Wasiluk, T., Średzińska, M., Rybińska, K., Dziemiańczuk, M., Radziwon, P., Kuźma, M., & Radziwon, P. (2026). Pooled granulocyte component–a worthy rival to the apheresis product?. Advances in Medical Sciences, 71(1), 27-39. https://doi.org/10.1016/j.advms.2026.01.002
Vancouver
Szumowski A, Wasiluk T, Średzińska M, Rybińska K, Dziemiańczuk M, Radziwon P, et al. Pooled granulocyte component–a worthy rival to the apheresis product?. Advances in Medical Sciences. 2026;71(1):27-39. doi:10.1016/j.advms.2026.01.002
BibTeX
@article{Szumowski2026,
author = {Szumowski, Artur and Wasiluk, Tomasz and Średzińska, Magdalena and Rybińska, Kamila and Dziemiańczuk, Mateusz and Radziwon, Paulina and Kuźma, Michał and Radziwon, Piotr},
title = {Pooled granulocyte component–a worthy rival to the apheresis product?},
journal = {Advances in Medical Sciences},
year = {2026},
volume = {71},
number = {1},
pages = {27--39},
doi = {10.1016/j.advms.2026.01.002}
}
EUVIMED