EUVIMEDEUVIMED entdecken
VergleichsstudieEvaluationsstudie

Evaluation of 2 intraoral scanners and a desktop scanner for replicating removable complete dentures of various anatomies

Louise Le Texier, Emmanuel Nicolas, Cindy Batisse

The Journal of the American Dental Association · 2025

DOI: 10.1016/j.adaj.2025.07.013 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Journal of the American Dental Association, 2025. Verfasst von Louise Le Texier und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: Denture, Complete, Mandible, Imaging, Three-Dimensional, Maxilla. Die Arbeit nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Technological advances have enabled intraoral scanners (IOSs) to replicate removable complete dentures (RCDs). The authors evaluated the acquisition effectiveness and accuracy of scanners for RCD replication and the impact of artificial landmarks on acquisition success for maxillary (mx) RCDs. METHODS: Two IOSs (Primescan, Dentsply Sirona and TRIOS 4, 3Shape A/S) and 1 desktop scanner (DS) (D2000, 3Shape A/S) scanned 10 mx and 10 mandibular RCDs. Mx RCDs were rescanned with IOSs using artificial landmarks. Acquired files were compared with the reference, the virtual RCD design file using Geomagic software (3D Systems). Objective measurements included acquisition effectiveness, assessed visually and statistically (Pearson χ2 test); accuracy, evaluated through trueness (average closeness); and precision (repeatability) (univariate analysis of variance and Student-Newman-Keuls test, α = .05); and clinical accuracy, assessed using tolerance thresholds and colorimetric deviation maps. RESULTS: Only the DS successfully replicated all RCDs. The IOSs failed to acquire some mx RCDs (Primescan, 50%; TRIOS 4, 10%) with no substantial improvement using landmarks. The DS had the highest trueness (mean [SD], 28 [22] μm; P < .05). Primescan and TRIOS 4 had similar trueness (mean [SD], 59 [19] μm and 60 [25] μm, respectively). The DS and Primescan had superior precision (mean [SD], 72 [36] μm and 70 [20] μm, respectively) than TRIOS 4 (mean [SD], 104 [29] μm) (P < .05). CONCLUSIONS: The DS is the most reliable for replicating RCDs. RCD characteristics influenced IOS acquisition success. PRACTICAL IMPLICATIONS: Digital RCD scanning may enhance clinical workflows. Acquiring the mandibular RCD is more feasible than acquiring the mx RCD. Optimizing techniques and identifying factors facilitating acquisition are essential for clinical viability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Denture, CompleteMandibleImaging, Three-DimensionalMaxillaDenture DesignReproducibility of ResultsAnatomic LandmarksSoftwareHumansDenture Precision AttachmentColorimetry

Stichwörter der Autor:innen

Accuracyin vitro studyintraoral scannerprecisionremovable complete denturetrueness

Zitieren

APA

Le Texier, L., Nicolas, E., & Batisse, C. (2025). Evaluation of 2 intraoral scanners and a desktop scanner for replicating removable complete dentures of various anatomies. The Journal of the American Dental Association. https://doi.org/10.1016/j.adaj.2025.07.013

Vancouver

Le Texier L, Nicolas E, Batisse C. Evaluation of 2 intraoral scanners and a desktop scanner for replicating removable complete dentures of various anatomies. The Journal of the American Dental Association. 2025. doi:10.1016/j.adaj.2025.07.013

BibTeX
@article{LeTexier2025,
  author = {Le Texier, Louise and Nicolas, Emmanuel and Batisse, Cindy},
  title = {Evaluation of 2 intraoral scanners and a desktop scanner for replicating removable complete dentures of various anatomies},
  journal = {The Journal of the American Dental Association},
  year = {2025},
  doi = {10.1016/j.adaj.2025.07.013}
}
Kostenlos starten →