EUVIMEDEUVIMED entdecken
Crossref

Accurate control of microspheres by surface acoustic waves for quantitative force characterization and cell mechanics measurement

Hengchao Qu, Jialin Shi, Hongyu Wang, Zijian Zhang, Tong Yang, Shitong Wang, Huiyao Shi, Xiaoduo Wang, Peng Yu, Wenfeng Liang, Lianqing Liu

Acta Biomaterialia · 2026-08 · 220 · 196-208

DOI: 10.1016/j.actbio.2026.07.028 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Biomaterialia, 2026-08. Verfasst von Hengchao Qu und 10 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Robotics and Intelligent Systems, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China; Univ…. Hauptthemen laut MEDLINE: Microspheres, Sound, Myoblasts, Acoustics. Die Arbeit nennt 37 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The mechanical properties of cells are critical indicators of cellular physiological state and function. However, existing technologies still face challenges in achieving non-contact, force-calibrated, and precisely controlled single-probe measurements of single-cell mechanical properties. A phase-programmable surface acoustic wave (SAW) platform is presented, in which orthogonally arranged interdigitated transducers (IDTs) generate controllable acoustic fields for deterministic two-dimensional manipulation of microspheres. Dynamic phase modulation of the SAW fields enables high-precision microsphere steering while producing tunable acoustic radiation forces in the piconewton-nanonewton range. To enable direct quantitative characterization of acoustic forces, a calibrated microneedle-microsphere force probe is integrated into the platform. This configuration establishes an experimental phase-force relationship, enabling in situ calibration of acoustic radiation forces without relying on theoretical models or indirect calculation. Based on this experimentally calibrated acoustic force framework, SAW-driven 5 μm microspheres are employed as localized single probes to perform controlled acoustic indentation of adherent C2C12 myoblasts. The apparent Young's modulus is determined to be 1.63 ± 0.21 kPa using Hertzian contact mechanics and shows agreement with AFM-based measurements under comparable experimental conditions. Overall, this work establishes a calibrated acoustic radiation force measurement and single-cell apparent Young's modulus characterization approach. This approach may have potential significance for non-contact mechanophenotyping and lab-on-chip based cell mechanics studies. STATEMENT OF SIGNIFICANCE: Accurate single-cell mechanical characterization is limited by the lack of direct force calibration and controllable acoustic loading in SAW-based techniques. In this work, we implemented a phase-programmable SAW platform that enables deterministic microsphere manipulation and controllable acoustic force generation. By integrating a calibrated microneedle-microsphere probe, we established a direct phase-force relationship, enabling in situ and direct measurement of acoustic radiation forces and overcoming reliance on theoretical or indirect force estimation. This calibrated acoustic manipulation framework further enables controlled probe-based indentation of adherent cells and quantitative determination of their apparent Young's modulus. The proposed work may advance acoustic force-based mechanophenotyping and provide a promising pathway toward scalable, chip-integrated single-cell mechanical analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrospheresSoundMyoblastsAcousticsAnimalsMiceCell LineElastic ModulusSurface PropertiesMicroscopy, Atomic ForceCalibration

Stichwörter der Autor:innen

Acoustic radiation forceAcoustic tweezersCell mechanicsMicrospheres manipulationSurface acoustic waves (SAWs)

Autor:innen und Institutionen

  • State Key Laboratory of Robotics and Intelligent Systems, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
  • University of Chinese Academy of Sciences, Beijing, 100049, China.
  • School of Mechanical Engineering, Shenyang Jianzhu University, Shenyang, 110168, China.
  • School of Mechanical Engineering, Shenyang Jianzhu University, Shenyang, 110168, China. Electronic address: liangwf@sjzu.edu.cn.
  • University of Chinese Academy of Sciences, Beijing, 100049, China. Electronic address: lqliu@sia.cn.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Qu, H., Shi, J., Wang, H., Zhang, Z., Yang, T., Wang, S., Shi, H., Wang, X., Yu, P., Liang, W., & Liu, L. (2026). Accurate control of microspheres by surface acoustic waves for quantitative force characterization and cell mechanics measurement. Acta Biomaterialia, 220, 196-208. https://doi.org/10.1016/j.actbio.2026.07.028

Vancouver

Qu H, Shi J, Wang H, Zhang Z, Yang T, Wang S, et al. Accurate control of microspheres by surface acoustic waves for quantitative force characterization and cell mechanics measurement. Acta Biomaterialia. 2026;220:196-208. doi:10.1016/j.actbio.2026.07.028

BibTeX
@article{Qu2026,
  author = {Qu, Hengchao and Shi, Jialin and Wang, Hongyu and Zhang, Zijian and Yang, Tong and Wang, Shitong and Shi, Huiyao and Wang, Xiaoduo and Yu, Peng and Liang, Wenfeng and Liu, Lianqing},
  title = {Accurate control of microspheres by surface acoustic waves for quantitative force characterization and cell mechanics measurement},
  journal = {Acta Biomaterialia},
  year = {2026},
  volume = {220},
  pages = {196--208},
  doi = {10.1016/j.actbio.2026.07.028}
}
Kostenlos starten →