Synchrotron tomography-based inversion pipeline for estimating elastic properties for rat vertebral endplate finite element models
Acta Biomaterialia · 2026-05 · 215 · 148-160
DOI: 10.1016/j.actbio.2026.03.032 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Biomaterialia, 2026-05. Verfasst von Jishizhan Chen und 10 weiteren Autor:innen. Beteiligte Einrichtung: Multiscale X-ray Imaging (MXI) Lab, Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, UK. Electronic address: jis…. Hauptthemen laut MEDLINE: Finite Element Analysis, Synchrotrons, Lumbar Vertebrae, Tomography, X-Ray Computed. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 61 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Research Council, Initiative Foundation, Silicon Valley Community Foundation.
Abstract (Originalsprache)
Lower back pain is linked to vertebral biomechanics, with vertebral endplates (VEPs) playing a key role. Finite element modelling (FEM) is a powerful tool for studying VEP biomechanics but relies on accurate material property inputs, which remain difficult to obtain. Synchrotron computed tomography (sCT) enables detailed visualisation of intact VEP microstructure under near-physiological loads in situ, with three-dimensional strain fields obtained by digital volume correlation (DVC) providing experimental reference data for FEM validation. We applied inverse finite element methodologies to estimate the elastic properties of rat VEPs by integrating DVC data into an image-based FE model. Our pipeline estimated an elastic modulus of 129 MPa and a Poisson's ratio of 0.24 in a rat lumbar segment. The first-order Wasserstein distance between FEM and DVC strain distributions ranged from 0.08% to 0.28%, with Bland-Altman analysis revealing
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Multiscale X-ray Imaging (MXI) Lab, Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, UK. Electronic address: jishizhan.chen@ucl.ac.uk.
- Multiscale X-ray Imaging (MXI) Lab, Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, UK; Research Complex at Harwell, Rutherford Appleton Laboratory, Oxfordshire OX11 0FA, UK.
- School of Engineering and Materials Sciences, Queen Mary University of London, London E1 4NS, UK.
- Multiscale X-ray Imaging (MXI) Lab, Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, UK.
- Department of Comparative Biomedical Sciences, Royal Veterinary College, London NW1 0TU, UK.
- Diamond Light Source, Didcot OX11 0DE, UK.
Förderung
- Medical Research Council
- Initiative Foundation
- Silicon Valley Community Foundation
- Engineering and Physical Sciences Research Council
- The Chan Zuckerberg Initiative
Zitieren
APA
Chen, J., Parmenter, A., Sharma, A., Newham, E., Bele, E., Marussi, S., Pitsillides, A. A., Terrill, N. J., Mitchell, C., Gupta, H. S., & Lee, P. D. (2026). Synchrotron tomography-based inversion pipeline for estimating elastic properties for rat vertebral endplate finite element models. Acta Biomaterialia, 215, 148-160. https://doi.org/10.1016/j.actbio.2026.03.032
Vancouver
Chen J, Parmenter A, Sharma A, Newham E, Bele E, Marussi S, et al. Synchrotron tomography-based inversion pipeline for estimating elastic properties for rat vertebral endplate finite element models. Acta Biomaterialia. 2026;215:148-160. doi:10.1016/j.actbio.2026.03.032
BibTeX
@article{Chen2026,
author = {Chen, Jishizhan and Parmenter, Alissa and Sharma, Aikta and Newham, Elis and Bele, Eral and Marussi, Sebastian and Pitsillides, Andrew A and Terrill, Nick J and Mitchell, Christopher and Gupta, Himadri S and Lee, Peter D},
title = {Synchrotron tomography-based inversion pipeline for estimating elastic properties for rat vertebral endplate finite element models},
journal = {Acta Biomaterialia},
year = {2026},
volume = {215},
pages = {148--160},
doi = {10.1016/j.actbio.2026.03.032}
}
EUVIMED