Fachartikel in der Zeitschrift Acta Biomaterialia, 2026-01. Verfasst von Christoph Brandt-Wunderlich und 12 weiteren Autor:innen. Beteiligte Einrichtung: Institute for ImplantTechnology and Biomaterials e.V., Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemuende, Germany. Electronic address: christoph.…. Hauptthemen laut MEDLINE: Magnesium, Coronary Vessels, Absorbable Implants, Tissue Scaffolds. Die Arbeit nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Social Fund Plus, European Regional Development Fund, Bundesministerium für Forschung, Technologie und Raumfahrt.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The elastic properties of coronary arteries are associated with different vascular conditions, in particular the degree of severity and pathology of coronary artery disease. In contrast to permanent stents, bioresorbable scaffolds provide temporary support to the treated lesion while allowing for restoration of the physiological vasomotion due to resorption within a certain period of time. Coronary artery distensibility may serve as a measure for vascular restoration after implantation and in vivo degradation of a bioresorbable scaffold. This study presents an investigation of the distensibility of porcine coronary arteries two and four years after implantation of a resorbable magnesium-based scaffold (RMS, FreesolveTM scaffold prototype and FreesolveTM scaffold, respectively, Teleflex) based on measurements of the pressure-dependent luminal area using an ex vivo test setup including intravascular optical coherence tomography. In case of a normotensive pressure regime, mean distensibility values were found to be 1.45 ± 0.47 × 10-3 mmHg-1 for the untreated artery regions and 1.03 × 10-3 mmHg-1 for the RMS region after two years in vivo degradation (71% distensibility recovery) as well as 1.40 ± 0.01 × 10-3 mmHg-1 after four years in vivo degradation (97% distensibility recovery), respectively. Reference measurements of a permanent drug eluting stent region revealed a distensibility of 0.80 × 10-3 mmHg-1. The findings of this study support the hypothesis that the radial elastic properties of the coronary artery can be regained following the in vivo degradation of a magnesium-based scaffold. STATEMENT OF SIGNIFICANCE: The elastic properties of coronary arteries are associated with the pathology of coronary artery disease. Measurement of coronary artery distensibility can be used to quantitatively assess passive radial elasticity of the arterial wall. Within the current study, two porcine hearts two years and four years after implantation of a resorbable magnesium-based scaffold were investigated regarding their coronary artery distensibility. Using an ex vivo test setup based on intravascular optical coherence tomography overcomes many limitations of in vivo investigations. The results show an increasing distensibility recovery over degradation time. For the first time, the hypothesis that the elastic properties of the coronary arteries can be restored following the in vivo degradation of a magnesium-based scaffold could be verified by quantitative measurements of distensibility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MagnesiumCoronary VesselsAbsorbable ImplantsTissue ScaffoldsAnimalsSwineTomography, Optical Coherence

Stichwörter der Autor:innen

Bioresorbable magnesium-based scaffoldFreesolve(TM) scaffoldOCTcompliancedistensibilityin vivo degradationoptical coherence tomography

Substanzen

Magnesium

Autor:innen und Institutionen

  • Institute for ImplantTechnology and Biomaterials e.V., Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemuende, Germany. Electronic address: christoph.brandt@iib-ev.de.
  • Biotronik AG (a Teleflex company), Research & Development, Ackerstr. 6, 8180 Buelach, Switzerland.
  • Institute for ImplantTechnology and Biomaterials e.V., Friedrich-Barnewitz-Str. 4, 18119 Rostock-Warnemuende, Germany.
  • Institute for Biomedical Engineering, Rostock University Medical Center, Friedrich-Barnewitz-Str. 4, 18119 Rostock, Germany.

Förderung

  • European Social Fund Plus
  • European Regional Development Fund
  • Bundesministerium für Forschung, Technologie und Raumfahrt
  • Biotronik

Zitieren

APA

Brandt-Wunderlich, C., Fubel, A., Stiehm, M., Schmidt, W., Grossmann, S., Bonin, F., Kosche, F., Lenz, C., Baumann-Zumstein, P., Harder, C., Wolfer, M., Siewert, S., & Schmitz, K. P. (2026). Recovery of coronary artery distensibility after two and four years in vivo degradation of a resorbable magnesium-based scaffold. Acta Biomaterialia, 210, 617-628. https://doi.org/10.1016/j.actbio.2025.12.005

Vancouver

Brandt-Wunderlich C, Fubel A, Stiehm M, Schmidt W, Grossmann S, Bonin F, et al. Recovery of coronary artery distensibility after two and four years in vivo degradation of a resorbable magnesium-based scaffold. Acta Biomaterialia. 2026;210:617-628. doi:10.1016/j.actbio.2025.12.005

BibTeX
@article{BrandtWunderlich2026,
  author = {Brandt-Wunderlich, Christoph and Fubel, Armin and Stiehm, Michael and Schmidt, Wolfram and Grossmann, Swen and Bonin, Franziska and Kosche, Florence and Lenz, Christopher and Baumann-Zumstein, Philine and Harder, Claus and Wolfer, Markus and Siewert, Stefan and Schmitz, Klaus-Peter},
  title = {Recovery of coronary artery distensibility after two and four years in vivo degradation of a resorbable magnesium-based scaffold},
  journal = {Acta Biomaterialia},
  year = {2026},
  volume = {210},
  pages = {617--628},
  doi = {10.1016/j.actbio.2025.12.005}
}
Kostenlos starten →