Asymmetric mechanical behavior and pre-osteoblast differentiation in 3D printed Ti6Al4V-based triply periodic minimal surface bone-analogues: the role of pore topology
Acta Biomaterialia · 2025
DOI: 10.1016/j.actbio.2025.10.002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Biomaterialia, 2025. Verfasst von Bijay Kumar Karali und 3 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Biomaterials Science and Translational Research, Materials Research Centre, Indian Institute of Science, Bangalore 560012, India; Centr…. Hauptthemen laut MEDLINE: Titanium, Osteoblasts, Printing, Three-Dimensional, Cell Differentiation. Die Arbeit nennt 61 Literaturangaben. Gefördert von: Science and Engineering Research Board, Indian National Academy of Engineering, Centralized Otolaryngology Research Efforts.
Abstract (Originalsprache)
The manufacturability of the cellular structure-based materials represents one of the most emerging themes in the additive manufacturing of medical implants and devices. This has been more relevant as natural bone possesses a unique porous architecture, which cannot be mimicked in conventional manufacturing. Despite recent advances, a critical knowledge gap persists in connecting scaffold topology and manufacturability with the mechano-biological responses, governed by asymmetric 3D pore structures. In this perspective, the present study focuses on laser powder bed fusion (L-PBF) of Schwarz diamond-based triply periodic minimal surface (SDW-TPMS) structures in Ti6Al4V, while varying unit cell size from 2.5 to 3.0 mm. The extensive micro-computed tomography analysis of 3D pore topology using customised design evaluation protocols established the efficacy of L-PBF-based optimised process parameters on dimensional tolerance and manufacturability of the TPMS structures. Intriguingly, an asymmetric mechanical response with a clinically relevant combination of the compressive elastic modulus (14-20 GPa), tensile elastic modulus (38 - 55 GPa), compressive strength (413-547 MPa), and tensile strength (325-475 MPa), together with unique 3D pore architecture, closely resembled the properties of human cortical bone. While correlating the anisotropic pore topology to the asymmetric mechanical response using the Gibson-Ashby model, the bendingdominated response was revealed with exponents of ∼1.5 in compression and ∼2.0 in tension. Furthermore, in vitro studies demonstrate MC3T3-E1 pre-osteoblasts' adhesion, proliferation, and maturation with modulation of early osteogenic markers and bone mineralisation, both quantitatively and qualitatively. The confocal microscopy observations revealed the cellular bridging, migration, and colonisation, indicating cytocompatibility. The present study conclusively establishes that SDW-TPMS structures offer a compelling combination of cortical bone-mimicking mechanical properties and a favourable biological response. It highlights their potential for reconstructive surgeries of load-bearing joints. STATEMENT OF SIGNIFICANCE: Conventional high-modulus metallic implants can induce periprosthetic bone resorption via stress shielding. While additively manufactured porous biomaterials address this, a robust structure-property-function paradigm has remained elusive. This study presents a Ti6Al4V based TPMS scaffold that achieves the biomechanical fidelity for load-bearing applications while providing a microenvironment suitable for differentiataion of pre-osteoblasts. The central innovation is our use of quantitative pore network modeling to establish a predictive link between the as-manufactured pore topology, the scaffold's pronounced tension-compression asymmetry, and its pro-osteogenic biological response. This work provides a validated framework for the rational design of next-generation bio-integrated orthopedic implants.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratory of Biomaterials Science and Translational Research, Materials Research Centre, Indian Institute of Science, Bangalore 560012, India; Centre of Excellence for Dental and Orthopedic Applications, Materials Rese…
- Orthotech India Pvt Ltd, Gujarat 396001, India.
Förderung
- Science and Engineering Research Board
- Indian National Academy of Engineering
- Centralized Otolaryngology Research Efforts
- Department of Science and Technology, Ministry of Science and Technology, India
- Indian Institute of Science
Zitieren
APA
Karali, B. K., Suthar, S., Banerji, S., & Basu, B. (2025). Asymmetric mechanical behavior and pre-osteoblast differentiation in 3D printed Ti6Al4V-based triply periodic minimal surface bone-analogues: the role of pore topology. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2025.10.002
Vancouver
Karali BK, Suthar S, Banerji S, Basu B. Asymmetric mechanical behavior and pre-osteoblast differentiation in 3D printed Ti6Al4V-based triply periodic minimal surface bone-analogues: the role of pore topology. Acta Biomaterialia. 2025. doi:10.1016/j.actbio.2025.10.002