Visualization of the degradation of long-acting microneedles and correlation of drug release in vivo based on FRET mechanism
Acta Biomaterialia · 2024
DOI: 10.1016/j.actbio.2024.10.016 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Biomaterialia, 2024. Verfasst von Qingwei He und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Burns & Plastic Surgery, Guangzhou Red Cross Hospital, Faculty of Medical Science, Jinan University, Guangzhou 510006, China; State Key…. Hauptthemen laut MEDLINE: Fluorescence Resonance Energy Transfer, Needles, Drug Liberation. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 64 Literaturangaben. Gefördert von: Guangdong Provincial Natural Science Foundation, Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.
Abstract (Originalsprache)
This study introduces a live imaging technique for real-time, non-invasive monitoring of drug release from long-acting microneedles using FRET (Fluorescence Resonance Energy Transfer). Employing Cy5.5 and Cy7 as FRET pairs and levonorgestrel as the model drug, we fabricated microneedles with varying PLGA molecular weights, demonstrating distinct release profiles. The FRET-PLGA-10-MN demonstrated a rapid drug release profile, reaching nearly complete release within a two-day period, while FRET-PLGA-30-MN showed a sustained release over four days. Sensitized Emission FRET (SE-FRET) optimized the imaging process, providing a robust correlation between FRET signals and drug absorption. This method surpasses traditional pharmacokinetic studies by offering a more efficient and comprehensive analysis of microneedle release dynamics in vivo, paving the way for enhanced long-acting microneedle design and therapeutic outcomes. STATEMENT OF SIGNIFICANCE: 1. FRET technology was applied to microneedle drug delivery system for the first time, which realized real-time, quantitative and non-invasive monitoring of drug release process. 2. The long-term microneedle technique was combined with sensitized emission method, and the FRET remaining ratio was innovatively used to investigate the FRET characteristics of microneedles, and the fluorescence ratio of FRET and donor double-channel was quantitatively calculated. 3. The correlation between visual fluorescence images of FRET effect and semi-quantitative calculation results based on fluorescence intensity and drug release in vivo with drug-loaded microneedles was analyzed.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Burns & Plastic Surgery, Guangzhou Red Cross Hospital, Faculty of Medical Science, Jinan University, Guangzhou 510006, China; State Key Laboratory of Bioactive Molecules and Druggability Assessment, Jinan…
- State Key Laboratory of Bioactive Molecules and Druggability Assessment, Jinan University, Guangzhou 510006, China; College of Pharmacy, Jinan University, Guangzhou 510006, China.
Förderung
- Guangdong Provincial Natural Science Foundation
- Fundamental Research Funds for the Central Universities
- National Natural Science Foundation of China
Zitieren
APA
He, Q., Lu, H., Chen, Y., Zeng, H., & Hu, P. (2024). Visualization of the degradation of long-acting microneedles and correlation of drug release in vivo based on FRET mechanism. Acta Biomaterialia. https://doi.org/10.1016/j.actbio.2024.10.016
Vancouver
He Q, Lu H, Chen Y, Zeng H, Hu P. Visualization of the degradation of long-acting microneedles and correlation of drug release in vivo based on FRET mechanism. Acta Biomaterialia. 2024. doi:10.1016/j.actbio.2024.10.016
BibTeX
@article{He2024,
author = {He, Qingwei and Lu, Hong and Chen, Yuying and Zeng, Huiying and Hu, Ping},
title = {Visualization of the degradation of long-acting microneedles and correlation of drug release in vivo based on FRET mechanism},
journal = {Acta Biomaterialia},
year = {2024},
doi = {10.1016/j.actbio.2024.10.016}
}
EUVIMED