EUVIMEDEUVIMED entdecken
Crossref

Fish swim bladders as valve leaflets enhance the durability of transcatheter aortic valve replacement devices

Honghui Jiang, Jianming Li, Yuanyuan Kong, Lili Song, Jing Liu, Deling Kong, Yongjian Wu, Shengzhang Wang, Zhihong Wang

Acta Biomaterialia · 2026-02 · 211 · 216-226

DOI: 10.1016/j.actbio.2024.04.030 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Biomaterialia, 2026-02. Verfasst von Honghui Jiang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Key Laboratory of Biomaterial Research, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical Col…. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Heart Valve Prosthesis, Air Sacs, Aortic Valve. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Tianjin Municipal Science and Technology Program, Science Fund for Distinguished Young Scholars of Tianjin Municipality, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transcatheter aortic valve replacement (TAVR) has emerged as an effective therapy for inoperable patients with severe aortic stenosis (AS). However, calcification-induced limited durability restricts its application. Fish swim bladders (FSB), which are resistant to calcific degeneration, offer a viable solution to this challenge. In this study, we developed a new TAVR device using FSB as the valve leaflet. Furthermore, the in vitro durability, in vivo performance, and size selection of this TAVR device were assessed by an experimental study and finite element analysis. A self-expandable TAVR device was fabricated by suturing the FSB films into a 23 mm nitinol alloy frame. Further, hemodynamic performance, such as effective orifice area, transvalvular pressure difference and regurgitant fraction, the durability was tested by the pulsatile flow test and accelerated fatigue test, according to the ISO 5840-3. The effect of release size on hydrodynamic performance was also investigated. Finally, the in vivo performance of the TAVR device were examined using a porcine implantation model. The results showed that the strength of the FSB films satisfied the requirements for valve leaflets. The hemodynamic performance of the FSB TAVR device met the requirements of ISO 5840-3 standards. After 400 million cycles, the FSB showed no fiber loss, torn, perforation, or other valve failure phenomena. In porcine models, the devices were well-positioned, functioned well with no stenosis immediately after the operation. Collectively, we successfully developed a TAVR device with FSB as valve leaflets that exhibited good fatigue resistance. STATEMENT OF SIGNIFICANCE: The source of material for the leaflets of commercialized biological heart valves (BHVs) is mainly bovine pericardium, but this material suffers the following problems: large and uneven thickness of the material, the presence of α-Gal and Neu5Gc antigens, and the susceptibility to structural valve degradation (SVD). New material for BHVs leaflets is rarely reported. In this study, we prepared a transcatheter aortic valve (TAV) and performed long-term in vitro and short-term in vivo studies using fish swim bladder (FSB) as the leaflets. The study confirmed that FSB TAV device can complete 400 million fatigue tests and maintain the good morphology of the leaflets, and that it still maintains good functionality after a certain amount of compression, indicating that FSB is a promising material for leaflets.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementHeart Valve ProsthesisAir SacsAortic ValveAnimalsFishesHemodynamicsSwineMaterials Testing

Stichwörter der Autor:innen

DurabilityFinite element analysisFish swim bladderHeart valve leafletsHemodynamic performanceProsthesis-patient mismatchTAVRTranscatheter aortic valve replacement

Autor:innen und Institutionen

  • Tianjin Key Laboratory of Biomaterial Research, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin 300192, China.
  • Department of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai 200433, China.
  • Tianjin Key Laboratory of Biomaterial Research, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin 300192, China. Electronic address: liujing@bme.pumc.edu.…
  • Key Laboratory of Bioactive Materials of Ministry of Education, State Key Laboratory of Medicinal Chemical Biology, College of Life Science, Nankai University, Tianjin 300071, China.
  • National Center for Cardiovascular Disease, Fuwai Hospital, Beijing 100037, China.
  • Department of Aeronautics and Astronautics, Institute of Biomechanics, Fudan University, Shanghai 200433, China. Electronic address: szwang@fudan.edu.cn.

Förderung

  • Tianjin Municipal Science and Technology Program
  • Science Fund for Distinguished Young Scholars of Tianjin Municipality
  • National Natural Science Foundation of China
  • Chinese Academy of Meteorological Sciences
  • CAMS Innovation Fund for Medical Sciences

Zitieren

APA

Jiang, H., Li, J., Kong, Y., Song, L., Liu, J., Kong, D., Wu, Y., Wang, S., & Wang, Z. (2026). Fish swim bladders as valve leaflets enhance the durability of transcatheter aortic valve replacement devices. Acta Biomaterialia, 211, 216-226. https://doi.org/10.1016/j.actbio.2024.04.030

Vancouver

Jiang H, Li J, Kong Y, Song L, Liu J, Kong D, et al. Fish swim bladders as valve leaflets enhance the durability of transcatheter aortic valve replacement devices. Acta Biomaterialia. 2026;211:216-226. doi:10.1016/j.actbio.2024.04.030

BibTeX
@article{Jiang2026,
  author = {Jiang, Honghui and Li, Jianming and Kong, Yuanyuan and Song, Lili and Liu, Jing and Kong, Deling and Wu, Yongjian and Wang, Shengzhang and Wang, Zhihong},
  title = {Fish swim bladders as valve leaflets enhance the durability of transcatheter aortic valve replacement devices},
  journal = {Acta Biomaterialia},
  year = {2026},
  volume = {211},
  pages = {216--226},
  doi = {10.1016/j.actbio.2024.04.030}
}
Kostenlos starten →