The role of stiffness-matching in avoiding stress shielding-induced bone loss and stress concentration-induced skeletal reconstruction device failure
Acta Biomaterialia · 2024-01 · 173 · 51-65
DOI: 10.1016/j.actbio.2023.11.011 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Acta Biomaterialia, 2024-01. Verfasst von Agnieszka Chmielewska und 1 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA. Electronic address: chmielewska.1@osu.edu. Hauptthemen laut MEDLINE: Fractures, Bone. Die Arbeit wurde bisher 130-mal zitiert (Crossref) und nennt 174 Literaturangaben. Gefördert von: Christian College Consortium, Narodowe Centrum Nauki, Narodowe Centrum Badań i Rozwoju.
Abstract (Originalsprache)
It is well documented that overly stiff skeletal replacement and fixation devices may fail and require revision surgery. Recent attempts to better support healing and sustain healed bone have looked at stiffness-matching of these devices to the desired role of limiting the stress on fractured or engrafted bone to compressive loads and, after the reconstructed bone has healed, to ensure that reconstructive medical devices (implants) interrupt the normal loading pattern as little as possible. The mechanical performance of these devices can be optimized by adjusting their location, integration/fastening, material(s), geometry (external and internal), and surface properties. This review highlights recent research that focuses on the optimal design of skeletal reconstruction devices to perform during and after healing as the mechanical regime changes. Previous studies have considered auxetic materials, homogeneous or gradient (i.e., adaptive) porosity, surface modification to enhance device/bone integration, and choosing the device's attachment location to ensure good osseointegration and resilient load transduction. By combining some or all of these factors, device designers work hard to avoid problems brought about by unsustainable stress shielding or stress concentrations as a means of creating sustainable stress-strain relationships that best repair and sustain a surgically reconstructed skeletal site. STATEMENT OF SIGNIFICANCE: Although standard-of-care skeletal reconstruction devices will usually allow normal healing and improved comfort for the patient during normal activities, there may be significant disadvantages during long-term use. Stress shielding and stress concentration are amongst the most common causes of failure of a metallic device. This review highlights recent developments in devices for skeletal reconstruction that match the stiffness, while not interrupting the normal loading pattern of a healthy bone, and help to combat stress shielding and stress concentration. This review summarises various approaches to achieve stiffness-matching: application of materials with modulus close to that of the bone; adaptation of geometry with pre-defined mechanical properties; and/or surface modification that ensures good integration and proper load transfer to the bone.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA. Electronic address: chmielewska.1@osu.edu.
- The Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA; Department of Plastic & Reconstructive Surgery, The Ohio State University, Columbus, OH 43212, USA.
Förderung
- Christian College Consortium
- Narodowe Centrum Nauki
- Narodowe Centrum Badań i Rozwoju
- College of Engineering, Temple University
- Ohio State University
Zitieren
APA
Chmielewska, A., & Dean, D. (2024). The role of stiffness-matching in avoiding stress shielding-induced bone loss and stress concentration-induced skeletal reconstruction device failure. Acta Biomaterialia, 173, 51-65. https://doi.org/10.1016/j.actbio.2023.11.011
Vancouver
Chmielewska A, Dean D. The role of stiffness-matching in avoiding stress shielding-induced bone loss and stress concentration-induced skeletal reconstruction device failure. Acta Biomaterialia. 2024;173:51-65. doi:10.1016/j.actbio.2023.11.011
BibTeX
@article{Chmielewska2024,
author = {Chmielewska, Agnieszka and Dean, David},
title = {The role of stiffness-matching in avoiding stress shielding-induced bone loss and stress concentration-induced skeletal reconstruction device failure},
journal = {Acta Biomaterialia},
year = {2024},
volume = {173},
pages = {51--65},
doi = {10.1016/j.actbio.2023.11.011}
}
EUVIMED