Feasibility of capillary-driven orbital liquid mirror telescopes
Acta Astronautica · 2027-02 · 251 · 768-784
DOI: 10.1016/j.actaastro.2026.10.030 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Astronautica, 2027-02. Verfasst von Janoah Dietrich und 1 weiteren Autor:innen. Die Arbeit nennt 130 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Space-based liquid mirror telescopes (LMTs) have been recently proposed to overcome the scaling limits of traditional rigid mirrors. In these new space architectures, capillary forces would shape a reflective liquid into a spherical optical surface in microgravity. However, the equilibrium, stability, and dynamic behavior of such liquid interfaces remain largely uncharacterized under orbital perturbations. This study investigates the feasibility of space LMTs by combining axisymmetric capillary with thin-film models. Solar radiation pressure and self-gravitation are found to be the dominant perturbations in Sun--Earth L2 orbits, causing equilibrium deformations that exceed the $\lambda/20$ optical threshold at apertures above 0.86~m for visible ($\lambda = 380$~nm) and 1.58~m for near-infrared observatories ($\lambda = 2.5~\mu \mathrm{m}$). Micrometeoroid impacts self-heal within seconds to minutes, settling after filling requires years to decades at large apertures, and propulsive maneuvers breach optical limits within seconds to hours. These results highlight the need for interface control in large-scale systems such as NASA's 50~m Fluidic Telescope (FLUTE). Thermocapillary actuation supports apertures of 2.3/8.0~m (VIS/NIR) at $100~\mu \mathrm{K}$ and 10.6/37.7~m at $10~\mu \mathrm{K}$ resolution. Simultaneously, parasitic Marangoni flows impose sub-mK uniformity requirements for NIR and 1--$100~\mu \mathrm{K}$ for visible operation on any capillary LMT. Departing the capillary regime by imposing a surface-normal settling acceleration, ranging from 39~mm\,s$^{-2}$ (NIR,5~m) to 17~m\,s$^{-2}$ (VIS,50~m), is the most promising route to tens of meters in aperture. This approach enables a passive implementation, effectively suppressing perturbation induced interface distortions and thermal Marangoni flows. Keywords: Liquid mirror telescope, Optics, Space
Zitieren
APA
Dietrich, J., & Romero-Calvo, Á. (2027). Feasibility of capillary-driven orbital liquid mirror telescopes. Acta Astronautica, 251, 768-784. https://doi.org/10.1016/j.actaastro.2026.10.030
Vancouver
Dietrich J, Romero-Calvo Á. Feasibility of capillary-driven orbital liquid mirror telescopes. Acta Astronautica. 2027;251:768-784. doi:10.1016/j.actaastro.2026.10.030
BibTeX
@article{Dietrich2027,
author = {Dietrich, Janoah and Romero-Calvo, Álvaro},
title = {Feasibility of capillary-driven orbital liquid mirror telescopes},
journal = {Acta Astronautica},
year = {2027},
volume = {251},
pages = {768--784},
doi = {10.1016/j.actaastro.2026.10.030}
}
EUVIMED