EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Deep Learning Super-Resolution CT Versus Ultra–High-Resolution CT: A Direct Comparison in Cadaveric Human Lungs

Midori Ueno, Masahiro Yanagawa, Akinori Hata, Kazuki Yamagata, Shuhei Doi, Takehito Imai, Miyuki Tomiyama, Daiki Nishigaki, Yukiko Tokuda, Noriyuki Tomiyama

Academic Radiology · 2026-10

DOI: 10.1016/j.acra.2026.09.072 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2026-10. Verfasst von Midori Ueno und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The University of Osaka Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, Japan. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: Deep learning-based high-resolution computed tomography (CT) of the lung parenchyma has not been directly compared with ultra-high-resolution CT (UHR-CT). We compared image quality between deep learning-based super-resolution CT and UHR-CT using identical cadaveric human lungs. MATERIALS AND METHODS: This retrospective study included 10 cadaveric human lungs scanned using conventional CT and UHR-CT at two dose levels (9 mGy, 2 mGy). Five reconstruction methods were evaluated, including deep learning-based synthetic super-resolution CT (CCT-1024-PIQE) and UHR-CT-derived high-resolution images reconstructed using a deep learning-based denoising algorithm (UHR-1024-AiCE). Two radiologists independently assessed the bronchioles, seven abnormal findings, and overall image quality using a 5-point scale. The objective image noise was also quantified. Statistical comparisons were performed using the Wilcoxon signed-rank test with Benjamini-Hochberg correction. RESULTS: At 9 mGy, no significant differences were observed in the bronchioles, whereas UHR-1024-AiCE demonstrated higher scores than CCT-1024-PIQE for ground-glass opacities and intralobular reticulation (all P ≤ 0.007). At 2 mGy, CCT-1024-PIQE showed no significant differences from UHR-1024-AiCE for most findings. Compared with the 512-matrix reconstructions, CCT-1024-PIQE achieved consistently higher visual scores at both dose levels (most comparisons, P < 0.05). Image noise increased at 2 mGy across all methods, while PIQE-based reconstructions showed lower noise (P < 0.001). CONCLUSION: Deep learning-based super-resolution CT showed no significant differences from UHR-CT in many pulmonary findings, particularly under low-dose conditions, while improving visualization compared to conventional 512-matrix reconstructions.

Schlagwörter

Stichwörter der Autor:innen

Deep learning–based super-resolution CT imageLungUltra–high-resolution CT

Autor:innen und Institutionen

  • Department of Radiology, The University of Osaka Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, Japan.
  • Department of Radiology, The University of Osaka Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, Japan. Electronic address: m-yanagawa@radiol.med.osaka-u.ac.jp.

Zitieren

APA

Ueno, M., Yanagawa, M., Hata, A., Yamagata, K., Doi, S., Imai, T., Tomiyama, M., Nishigaki, D., Tokuda, Y., & Tomiyama, N. (2026). Deep Learning Super-Resolution CT Versus Ultra–High-Resolution CT: A Direct Comparison in Cadaveric Human Lungs. Academic Radiology. https://doi.org/10.1016/j.acra.2026.09.072

Vancouver

Ueno M, Yanagawa M, Hata A, Yamagata K, Doi S, Imai T, et al. Deep Learning Super-Resolution CT Versus Ultra–High-Resolution CT: A Direct Comparison in Cadaveric Human Lungs. Academic Radiology. 2026. doi:10.1016/j.acra.2026.09.072

BibTeX
@article{Ueno2026,
  author = {Ueno, Midori and Yanagawa, Masahiro and Hata, Akinori and Yamagata, Kazuki and Doi, Shuhei and Imai, Takehito and Tomiyama, Miyuki and Nishigaki, Daiki and Tokuda, Yukiko and Tomiyama, Noriyuki},
  title = {Deep Learning Super-Resolution CT Versus Ultra–High-Resolution CT: A Direct Comparison in Cadaveric Human Lungs},
  journal = {Academic Radiology},
  year = {2026},
  doi = {10.1016/j.acra.2026.09.072}
}
Kostenlos starten →