RATIONALE AND OBJECTIVES: To characterize the association between recorded maximum delivered injection rate and peak pressure during contrast-enhanced computed tomography (CT) through upper-arm central venous (CV) ports and estimate port- and viscosity-specific flow-rate thresholds corresponding to 13 kg/cm². MATERIALS AND METHODS: This retrospective study included 205 CT examinations from 102 patients with 103 implanted upper-arm CV ports. Three port systems and eight iodinated contrast media (ICM) formulations grouped by viscosity were evaluated. A no-intercept linear model estimated separate slopes and 13 kg/cm² thresholds for nine port-viscosity combinations using the recorded maximum delivered rate with port-clustered robust inference. Sensitivity analyses excluded pressure-limit activation and flow-reduction cases and examined the 13 kg/cm² preset subgroup. RESULTS: All subgroup pressure-flow slopes were statistically significant (all p 5.0 mL/s and changed by at most 5.6% in exclusion analyses. Similar patterns persisted in the 13 kg/cm² preset subgroup despite sparse cells. CONCLUSION: Under the evaluated clinical conditions, pressure-flow relationships through upper-arm CV ports differed by port system and ICM viscosity group. Model-based descriptive thresholds provide port- and viscosity-specific pressure-flow reference information for the evaluated combinations.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Gunma University Hospital, Maebashi, Japan. Electronic address: ysato@gunma-u.ac.jp.
- Department of Radiological Sciences, Faculty of Medical Science and Technology, Gunma Paz University, Takasaki, Japan.
- Department of Diagnostic Radiology and Nuclear Medicine, Gunma University Graduate School of Medicine, Maebashi, Japan.
- Department of Radiology, Gunma University Hospital, Maebashi, Japan.
Zitieren
APA
Sato, Y., Fukushima, Y., Kumasaka, S., Takeuchi, T., Ozaki, D., Sakai, Y., Suto, T., & Tsushima, Y. (2026). Model-based Pressure-threshold Flow-rate Estimation for Contrast Injection via Upper-arm Central Venous Ports. Academic Radiology. https://doi.org/10.1016/j.acra.2026.09.033
Vancouver
Sato Y, Fukushima Y, Kumasaka S, Takeuchi T, Ozaki D, Sakai Y, et al. Model-based Pressure-threshold Flow-rate Estimation for Contrast Injection via Upper-arm Central Venous Ports. Academic Radiology. 2026. doi:10.1016/j.acra.2026.09.033
BibTeX
@article{Sato2026,
author = {Sato, Yusuke and Fukushima, Yasuhiro and Kumasaka, Soma and Takeuchi, Tomokazu and Ozaki, Daisuke and Sakai, Yoshiyuki and Suto, Takayuki and Tsushima, Yoshito},
title = {Model-based Pressure-threshold Flow-rate Estimation for Contrast Injection via Upper-arm Central Venous Ports},
journal = {Academic Radiology},
year = {2026},
doi = {10.1016/j.acra.2026.09.033}
}
EUVIMED