Assessment of Pulmonary Vascular Stent Morphology Using Intra-procedural Cone-Beam CT in Fibrosing Mediastinitis: Imaging Agreement and Clinical Implications
Academic Radiology · 2026-10
DOI: 10.1016/j.acra.2026.09.004 ↗Kurz gefasst
Fachartikel in der Zeitschrift Academic Radiology, 2026-10. Verfasst von Jielong Lin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou 510010, China (J.L.). Die Arbeit nennt 40 Literaturangaben. Gefördert von: Guangzhou Science and Technology Program Key Projects, National Key Research and Development Program of China, Guangzhou Municipal Science and Technology Project.
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: Percutaneous Pulmonary Vascular Stent Angioplasty (PPVSA) is a key treatment for pulmonary vascular stenosis in Fibrosing Mediastinitis (FM). This study evaluated the added value of intraoperative cone-beam computed tomography (CBCT) beyond conventional angiography for post-stenting assessment during PPVSA. MATERIALS AND METHODS: This retrospective single-center study included 54 consecutive FM patients who underwent PPVSA between August 2021 and May 2024, comprising 114 stents (99 arterial and 15 venous). All patients underwent intraoperative CBCT, angiography, and follow-up computed tomography pulmonary angiography (CTPA) for assessment of stent geometry. Agreement between imaging modalities was evaluated using correlation, Bland-Altman, and reproducibility analyses. Associations between CBCT-derived parameters, hemodynamic outcomes, and stent patency were further explored. RESULTS: Among 54 patients (57.26 ± 11.47 years; 17 females [31.48%]), CBCT demonstrated excellent correlation with first follow-up CTPA. For maximum stent diameter, the correlation between CBCT and CTPA was r = 0.99, compared with r = 0.94 for angiography. For minimum stent diameter, the corresponding correlations were r = 0.99 and r = 0.85, respectively (all p < 0.001). Bland-Altman analysis showed smaller measurement bias and narrower limits of agreement for CBCT than for angiography. During a median imaging follow-up of 614.50 days, in-stent restenosis occurred in 15.79% of stents, whereas complete stent occlusion occurred in 1.75% of stents. Stents with a minimum-to-maximum diameter ratio
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou 510010, China (J.L.).
- State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, National Center for Respiratory Medicine, Joint International Research Laboratory of Respiratory Health, Guangdong…
- Department of Medical Ultrasonics, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou 510655, China (Z.L.).
Förderung
- Guangzhou Science and Technology Program Key Projects
- National Key Research and Development Program of China
- Guangzhou Municipal Science and Technology Project
- Key Technologies Research and Development Program
Zitieren
APA
Lin, J., Long, J., Xia, X., Li, Z., Guo, W., Wu, X., & Hong, C. (2026). Assessment of Pulmonary Vascular Stent Morphology Using Intra-procedural Cone-Beam CT in Fibrosing Mediastinitis: Imaging Agreement and Clinical Implications. Academic Radiology. https://doi.org/10.1016/j.acra.2026.09.004
Vancouver
Lin J, Long J, Xia X, Li Z, Guo W, Wu X, et al. Assessment of Pulmonary Vascular Stent Morphology Using Intra-procedural Cone-Beam CT in Fibrosing Mediastinitis: Imaging Agreement and Clinical Implications. Academic Radiology. 2026. doi:10.1016/j.acra.2026.09.004
BibTeX
@article{Lin2026,
author = {Lin, Jielong and Long, Jiawei and Xia, Xinye and Li, Zhenyi and Guo, Wenliang and Wu, Xiaofeng and Hong, Cheng},
title = {Assessment of Pulmonary Vascular Stent Morphology Using Intra-procedural Cone-Beam CT in Fibrosing Mediastinitis: Imaging Agreement and Clinical Implications},
journal = {Academic Radiology},
year = {2026},
doi = {10.1016/j.acra.2026.09.004}
}
EUVIMED