EUVIMEDEUVIMED entdecken
Crossref

Feasibility of Dynamic Volume Perfusion CT for Treatment Response Monitoring in Pancreatic Adenocarcinoma

Hebing Chen, Juan Li, Xiao Wang, Yuhong Wang, Dingyan Cao, Huadan Xue

Academic Radiology · 2026-09

DOI: 10.1016/j.acra.2026.08.112 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2026-09. Verfasst von Hebing Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan No. 1…. Die Arbeit nennt 15 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Peking Union Medical College Hospital, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: Perfusion CT has shown predictive value for tumor response, grade, and recurrence in pancreatic adenocarcinoma (PAC). However, its utility for real-time dynamic monitoring during chemotherapy has not been systematically evaluated. This study aimed to evaluate the feasibility of dynamic volume perfusion CT (dVPCT) for treatment response monitoring in patients with PAC. MATERIALS AND METHODS: This retrospective study included consecutive patients with pathologically confirmed PAC who underwent systemic chemotherapy and dVPCT between December 2024 and May 2026. Treatment response was assessed according to Response Evaluation Criteria in Solid Tumors (RECIST) version 1.1. For cross-sectional analysis, blood flow (BF), blood volume (BV), mean transit time (MTT), and flow extraction product (FEP) measured at the first response-evaluable dVPCT examination were compared between the disease-control group (partial response [PR] or stable disease [SD]) and the progressive-disease (PD) group. For longitudinal analysis, patients with serial dVPCT examinations were included, and interval changes in perfusion parameters between consecutive examinations were calculated. Linear mixed-effects models were used to evaluate longitudinal associations. RESULTS: A total of 87 patients underwent 141 dVPCT examinations and were included in the study. Among them, 36 patients contributed 54 evaluable scan intervals for longitudinal analysis. In the cross-sectional analysis, BF was significantly higher in the PR/SD group than in the PD group (38.48 vs 26.98 mL/100mL/min, P = .013). In the longitudinal analysis, increases in BF (Estimate = 12.14, P = .011) were significantly associated with disease control after adjustment. CONCLUSION: Higher BF and longitudinal increases in BF were associated with better disease control during systemic chemotherapy. dVPCT can provide functional information complementary to RECIST 1.1-based response assessment at a radiation dose comparable to routine multiphase contrast-enhanced CT, supporting its potential role in treatment response monitoring in PAC.

Schlagwörter

Stichwörter der Autor:innen

Dynamic volume perfusion CTPancreatic adenocarcinomaTreatment response

Autor:innen und Institutionen

  • Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan No. 1, Wangfujing Street, Dongcheng District, Beijing 100730, China (H.C.,…
  • Department of General Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences & Peking Union Medical College, Shuaifuyuan No. 1, Wangfujing Street, Dongcheng District, Beijing 100730, China (…

Förderung

  • National Key Research and Development Program of China
  • Peking Union Medical College Hospital
  • National Natural Science Foundation of China

Zitieren

APA

Chen, H., Li, J., Wang, X., Wang, Y., Cao, D., & Xue, H. (2026). Feasibility of Dynamic Volume Perfusion CT for Treatment Response Monitoring in Pancreatic Adenocarcinoma. Academic Radiology. https://doi.org/10.1016/j.acra.2026.08.112

Vancouver

Chen H, Li J, Wang X, Wang Y, Cao D, Xue H. Feasibility of Dynamic Volume Perfusion CT for Treatment Response Monitoring in Pancreatic Adenocarcinoma. Academic Radiology. 2026. doi:10.1016/j.acra.2026.08.112

BibTeX
@article{Chen2026,
  author = {Chen, Hebing and Li, Juan and Wang, Xiao and Wang, Yuhong and Cao, Dingyan and Xue, Huadan},
  title = {Feasibility of Dynamic Volume Perfusion CT for Treatment Response Monitoring in Pancreatic Adenocarcinoma},
  journal = {Academic Radiology},
  year = {2026},
  doi = {10.1016/j.acra.2026.08.112}
}
Kostenlos starten →