EUVIMEDEUVIMED entdecken
Open Access

Reading, Fast and Slow: Characterizing Radiologists’ Visual Search Through Abdominal CT for Detecting Hepatic Metastases

Parvathy Sudhir Pillai, Scott S Hsieh, Hao Gong, Andrew Vercnocke, David A Cook, David R Holmes, Jeff L Fidler, Rickey E Carter, Shuai Leng, Lifeng Yu, Cynthia H McCollough, Joel G Fletcher

Academic Radiology · 2026-06 · 33 (6) · 2382-2390

DOI: 10.1016/j.acra.2026.02.018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2026-06. Verfasst von Parvathy Sudhir Pillai und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, Minnesota 55905 (P.S.P., S.S.H., H.G., A.V., J.L.F., S.L., L.Y., C.H.M., J.G.F.…. Hauptthemen laut MEDLINE: Liver Neoplasms, Tomography, X-Ray Computed, Eye Movements, Radiography, Abdominal. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: Previous studies suggest that "drilling" (eyes fixated at one location within a slice while scrolling rapidly between computed tomography (CT) slices) may be more effective than "scanning" (eyes move rapidly to search within each slice while scrolling slowly between slices) for detecting lesions, but evidence has been limited. The purpose of this study is to examine the association between sensitivity and either drilling or scanning for liver metastasis detection. MATERIALS AND METHODS: Twenty-five radiologists blinded to clinical and previous imaging information marked all suspected hepatic metastases in 40 contrast-enhanced liver CT exams while being monitored by eye-tracking technology. Eye movements were registered to the corresponding liver segment and slice. All livers and proven metastases were demarcated into Couinaud segments. Outcome measures included metastasis detection (sensitivity), interpretation time, average rate of scrolling, and average rate of segment change. RESULTS: There were 91 metastases, and mean sensitivity was 83%. In univariate analysis, higher reader sensitivity was associated with longer interpretation time (adjusted R2 = 0.35, regression coefficient = 5.25, p = 0.002) and smaller segment change rate (i.e., drilling) (adjusted R2 = 0.23, regression coefficient = -4.54, p = 0.009). Scrolling rate was not associated with sensitivity (p=0.37). A regression model predicting sensitivity from both interpretation time and segment change rate yielded an adjusted R2 of 0.43. CONCLUSION: Drilling may outperform scanning in sensitivity for detection of liver metastases when measured as segment change rate, but not as scrolling rate. Longer interpretation time is independently associated with higher sensitivity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Liver NeoplasmsTomography, X-Ray ComputedEye MovementsRadiography, AbdominalRadiographic Image Interpretation, Computer-AssistedHumansSensitivity and SpecificityFemaleReproducibility of ResultsMaleRadiologistsContrast MediaObserver Variation

Stichwörter der Autor:innen

Eye trackingReader performanceSearch errors

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, Minnesota 55905 (P.S.P., S.S.H., H.G., A.V., J.L.F., S.L., L.Y., C.H.M., J.G.F.).
  • Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, Minnesota 55905 (P.S.P., S.S.H., H.G., A.V., J.L.F., S.L., L.Y., C.H.M., J.G.F.). Electronic address: hsieh.scott@mayo.edu.
  • Department of Internal Medicine, Mayo Clinic, Rochester, Minnesota (D.A.C).
  • Biomedical Imaging Resource, Mayo Clinic, Rochester, Minnesota (D.R.H.).
  • Department of Quantitative Health Sciences Research, Mayo Clinic, Jacksonville, Florida (R.E.C.).

Förderung

  • NIBIB NIH HHS
  • National Institutes of Health
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Pillai, P. S., Hsieh, S. S., Gong, H., Vercnocke, A., Cook, D. A., Holmes, D. R., Fidler, J. L., Carter, R. E., Leng, S., Yu, L., McCollough, C. H., & Fletcher, J. G. (2026). Reading, Fast and Slow: Characterizing Radiologists’ Visual Search Through Abdominal CT for Detecting Hepatic Metastases. Academic Radiology, 33(6), 2382-2390. https://doi.org/10.1016/j.acra.2026.02.018

Vancouver

Pillai PS, Hsieh SS, Gong H, Vercnocke A, Cook DA, Holmes DR, et al. Reading, Fast and Slow: Characterizing Radiologists’ Visual Search Through Abdominal CT for Detecting Hepatic Metastases. Academic Radiology. 2026;33(6):2382-2390. doi:10.1016/j.acra.2026.02.018

BibTeX
@article{Pillai2026,
  author = {Pillai, Parvathy Sudhir and Hsieh, Scott S and Gong, Hao and Vercnocke, Andrew and Cook, David A and Holmes, David R and Fidler, Jeff L and Carter, Rickey E and Leng, Shuai and Yu, Lifeng and McCollough, Cynthia H and Fletcher, Joel G},
  title = {Reading, Fast and Slow: Characterizing Radiologists’ Visual Search Through Abdominal CT for Detecting Hepatic Metastases},
  journal = {Academic Radiology},
  year = {2026},
  volume = {33},
  number = {6},
  pages = {2382--2390},
  doi = {10.1016/j.acra.2026.02.018}
}
Kostenlos starten →