EUVIMEDEUVIMED entdecken
Vergleichsstudie

Performance Comparison of Cutting-Edge Large Language Models on the ACR In-Training Examination: An Update for 2025

Austin Young, Rinald Paloka, Ariba Islam, Prateek Prasanna, Virginia Hill, David Payne

Academic Radiology · 2025

DOI: 10.1016/j.acra.2025.09.008 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Academic Radiology, 2025. Verfasst von Austin Young und 5 weiteren Autor:innen. Beteiligte Einrichtung: Northwell Health, Mather Hospital, Port Jefferson, New York (A.Y.). Electronic address: austinyoungmd@gmail.com. Hauptthemen laut MEDLINE: Educational Measurement, Radiology, Internship and Residency, Clinical Competence. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study represents a continuation of prior work by Payne et al. evaluating large language model (LLM) performance on radiology board-style assessments, specifically the ACR diagnostic radiology in-training examination (DXIT). Building upon earlier findings with GPT-4, we assess the performance of newer, cutting-edge models, such as GPT-4o, GPT-o1, GPT-o3, Claude, Gemini, and Grok on standardized DXIT questions. In addition to overall performance, we compare model accuracy on text-based versus image-based questions to assess multi-modal reasoning capabilities. As a secondary aim, we investigate the potential impact of data contamination by comparing model performance on original versus revised image-based questions. METHODS: Seven LLMs - GPT-4, GPT-4o, GPT-o1, GPT-o3, Claude 3.5 Sonnet, Gemini 1.5 Pro, and Grok 2.0-were evaluated using 106 publicly available DXIT questions. Each model was prompted using a standardized instruction set to simulate a radiology resident answering board-style questions. For each question, the model's selected answer, rationale, and confidence score were recorded. Unadjusted accuracy (based on correct answer selection) and logic-adjusted accuracy (based on clinical reasoning pathways) were calculated. Subgroup analysis compared model performance on text-based versus image-based questions. Additionally, 63 image-based questions were revised to test novel reasoning while preserving the original diagnostic image to assess the impact of potential training data contamination. RESULTS: Across 106 DXIT questions, GPT-o1 demonstrated the highest unadjusted accuracy (71.7%), followed closely by GPT-4o (69.8%) and GPT-o3 (68.9%). GPT-4 (59.4%) and Grok 2.0 exhibited similar scores (59.4% and 52.8%). Claude 3.5 Sonnet had the lowest unadjusted accuracies (34.9%). Similar trends were observed for logic-adjusted accuracy, with GPT-o1 (60.4%), GPT-4o (59.4%), and GPT-o3 (59.4%) again outperforming other models, while Grok 2.0 and Claude 3.5 Sonnet lagged behind (34.0% and 30.2%, respectively). GPT-4o's performance was significantly higher on text-based questions compared to image-based ones. Unadjusted accuracy for the revised DXIT questions was 49.2%, compared to 56.1% on matched original DXIT questions. Logic-adjusted accuracy for the revised DXIT questions was 40.0% compared to 44.4% on matched original DXIT questions. No significant difference in performance was observed between original and revised questions. CONCLUSION: Modern LLMs, especially those from OpenAI, demonstrate strong and improved performance on board-style radiology assessments. Comparable performance on revised prompts suggests that data contamination may have played a limited role. As LLMs improve, they hold strong potential to support radiology resident learning through personalized feedback and board-style question review.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Educational MeasurementRadiologyInternship and ResidencyClinical CompetenceLanguageHumansUnited StatesLarge Language Models

Stichwörter der Autor:innen

Artificial intelligenceLLMLarge Language ModelsMedical educationRadiology education

Autor:innen und Institutionen

  • Northwell Health, Mather Hospital, Port Jefferson, New York (A.Y.). Electronic address: austinyoungmd@gmail.com.
  • Department of Radiology, Stony Brook University Hospital, Stony Brook, New York (R.P.).
  • New York Institute of Technology College of Medicine, Old Westbury, New York (A.I.).
  • Department of Biomedical Informatics, Stony Brook University Hospital, Stony Brook, New York (P.P.).
  • Department of Radiology, Northwestern University Hospital, Chicago, Illinois (V.H.).
  • Department of Radiology, Northwestern University Hospital, Chicago, Illinois (D.P.).

Zitieren

APA

Young, A., Paloka, R., Islam, A., Prasanna, P., Hill, V., & Payne, D. (2025). Performance Comparison of Cutting-Edge Large Language Models on the ACR In-Training Examination: An Update for 2025. Academic Radiology. https://doi.org/10.1016/j.acra.2025.09.008

Vancouver

Young A, Paloka R, Islam A, Prasanna P, Hill V, Payne D. Performance Comparison of Cutting-Edge Large Language Models on the ACR In-Training Examination: An Update for 2025. Academic Radiology. 2025. doi:10.1016/j.acra.2025.09.008

BibTeX
@article{Young2025,
  author = {Young, Austin and Paloka, Rinald and Islam, Ariba and Prasanna, Prateek and Hill, Virginia and Payne, David},
  title = {Performance Comparison of Cutting-Edge Large Language Models on the ACR In-Training Examination: An Update for 2025},
  journal = {Academic Radiology},
  year = {2025},
  doi = {10.1016/j.acra.2025.09.008}
}
Kostenlos starten →