A Mixed-attention Network for Automated Interventricular Septum Segmentation in Bright-blood Myocardial T2* MRI Relaxometry in Thalassemia
Academic Radiology · 2025
DOI: 10.1016/j.acra.2025.04.075 ↗Kurz gefasst
Fachartikel in der Zeitschrift Academic Radiology, 2025. Verfasst von Xiaofeng Wu und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Southern Medical University, Guangzhou 510000, China (X.W., H.W., Z.C., S.S., Z.L., X.Z., Y.F.); Guangdong Provinci…. Hauptthemen laut MEDLINE: Thalassemia, Magnetic Resonance Imaging, Ventricular Septum, Deep Learning. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Guangdong Provincial Natural Science Foundation, Innovative Research Group Project of the National Natural Science Foundation of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
RATIONALE AND OBJECTIVES: This study develops a deep-learning method for automatic segmentation of the interventricular septum (IS) in MR images to measure myocardial T2* and estimate cardiac iron deposition in patients with thalassemia. MATERIALS AND METHODS: This retrospective study used multiple-gradient-echo cardiac MR scans from 419 thalassemia patients to develop and evaluate the segmentation network. The network was trained on 1.5 T images from Center 1 and evaluated on 3.0 T unseen images from Center 1, all data from Center 2, and the CHMMOTv1 dataset. Model performance was assessed using five metrics, and T2* values were obtained by fitting the network output. Bland-Altman analysis, coefficient of variation (CoV), and regression analysis were used to evaluate the consistency between automatic and manual methods. RESULTS: MA-BBIsegNet achieved a Dice of 0.90 on the internal test set, 0.85 on the external test set, and 0.81 on the CHMMOTv1 dataset. Bland-Altman analysis showed mean differences of 0.08 (95% LoA: -2.79 ∼ 2.63) ms (internal), 0.29 (95% LoA: -4.12 ∼ 3.54) ms (external) and 0.19 (95% LoA: -3.50 ∼ 3.88) ms (CHMMOTv1), with CoV of 8.9%, 6.8%, and 9.3%. Regression analysis yielded r values of 0.98 for the internal and CHMMOTv1 datasets, and 0.99 for the external dataset (p < 0.05). CONCLUSION: The IS segmentation network based on multiple-gradient-echo bright-blood images yielded T2* values that were in strong agreement with manual measurements, highlighting its potential for the efficient, non-invasive monitoring of myocardial iron deposition in patients with thalassemia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Biomedical Engineering, Southern Medical University, Guangzhou 510000, China (X.W., H.W., Z.C., S.S., Z.L., X.Z., Y.F.); Guangdong Provincial Key Laboratory of Medical Image Processing & Guangdong Province Eng…
- Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning 530021, China (P.P.); NHC Key Laboratory of Thalassemia Medicine and Guangxi Key laboratory of Thalassemia Research, Nanning,…
Förderung
- Guangdong Provincial Natural Science Foundation
- Innovative Research Group Project of the National Natural Science Foundation of China
- National Natural Science Foundation of China
Zitieren
APA
Wu, X., Wang, H., Chen, Z., Sun, S., Lian, Z., Zhang, X., Peng, P., & Feng, Y. (2025). A Mixed-attention Network for Automated Interventricular Septum Segmentation in Bright-blood Myocardial T2* MRI Relaxometry in Thalassemia. Academic Radiology. https://doi.org/10.1016/j.acra.2025.04.075
Vancouver
Wu X, Wang H, Chen Z, Sun S, Lian Z, Zhang X, et al. A Mixed-attention Network for Automated Interventricular Septum Segmentation in Bright-blood Myocardial T2* MRI Relaxometry in Thalassemia. Academic Radiology. 2025. doi:10.1016/j.acra.2025.04.075
BibTeX
@article{Wu2025,
author = {Wu, Xiaofeng and Wang, Hangyu and Chen, Zeluan and Sun, Songsong and Lian, Zifeng and Zhang, Xinyuan and Peng, Peng and Feng, Yanqiu},
title = {A Mixed-attention Network for Automated Interventricular Septum Segmentation in Bright-blood Myocardial T2* MRI Relaxometry in Thalassemia},
journal = {Academic Radiology},
year = {2025},
doi = {10.1016/j.acra.2025.04.075}
}
EUVIMED