EUVIMEDEUVIMED entdecken
Crossref

A Mixed-attention Network for Automated Interventricular Septum Segmentation in Bright-blood Myocardial T2* MRI Relaxometry in Thalassemia

Xiaofeng Wu, Hangyu Wang, Zeluan Chen, Songsong Sun, Zifeng Lian, Xinyuan Zhang, Peng Peng, Yanqiu Feng

Academic Radiology · 2025

DOI: 10.1016/j.acra.2025.04.075 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2025. Verfasst von Xiaofeng Wu und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Southern Medical University, Guangzhou 510000, China (X.W., H.W., Z.C., S.S., Z.L., X.Z., Y.F.); Guangdong Provinci…. Hauptthemen laut MEDLINE: Thalassemia, Magnetic Resonance Imaging, Ventricular Septum, Deep Learning. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Guangdong Provincial Natural Science Foundation, Innovative Research Group Project of the National Natural Science Foundation of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: This study develops a deep-learning method for automatic segmentation of the interventricular septum (IS) in MR images to measure myocardial T2* and estimate cardiac iron deposition in patients with thalassemia. MATERIALS AND METHODS: This retrospective study used multiple-gradient-echo cardiac MR scans from 419 thalassemia patients to develop and evaluate the segmentation network. The network was trained on 1.5 T images from Center 1 and evaluated on 3.0 T unseen images from Center 1, all data from Center 2, and the CHMMOTv1 dataset. Model performance was assessed using five metrics, and T2* values were obtained by fitting the network output. Bland-Altman analysis, coefficient of variation (CoV), and regression analysis were used to evaluate the consistency between automatic and manual methods. RESULTS: MA-BBIsegNet achieved a Dice of 0.90 on the internal test set, 0.85 on the external test set, and 0.81 on the CHMMOTv1 dataset. Bland-Altman analysis showed mean differences of 0.08 (95% LoA: -2.79 ∼ 2.63) ms (internal), 0.29 (95% LoA: -4.12 ∼ 3.54) ms (external) and 0.19 (95% LoA: -3.50 ∼ 3.88) ms (CHMMOTv1), with CoV of 8.9%, 6.8%, and 9.3%. Regression analysis yielded r values of 0.98 for the internal and CHMMOTv1 datasets, and 0.99 for the external dataset (p < 0.05). CONCLUSION: The IS segmentation network based on multiple-gradient-echo bright-blood images yielded T2* values that were in strong agreement with manual measurements, highlighting its potential for the efficient, non-invasive monitoring of myocardial iron deposition in patients with thalassemia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ThalassemiaMagnetic Resonance ImagingVentricular SeptumDeep LearningImage Interpretation, Computer-AssistedHumansRetrospective StudiesMaleFemaleAdultAdolescentYoung AdultChild

Stichwörter der Autor:innen

Automatic segmentationBright-blood myocardial imagesMagnetic resonance imagingMyocardial iron overloadT2* measurement

Autor:innen und Institutionen

  • School of Biomedical Engineering, Southern Medical University, Guangzhou 510000, China (X.W., H.W., Z.C., S.S., Z.L., X.Z., Y.F.); Guangdong Provincial Key Laboratory of Medical Image Processing & Guangdong Province Eng…
  • Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning 530021, China (P.P.); NHC Key Laboratory of Thalassemia Medicine and Guangxi Key laboratory of Thalassemia Research, Nanning,…

Förderung

  • Guangdong Provincial Natural Science Foundation
  • Innovative Research Group Project of the National Natural Science Foundation of China
  • National Natural Science Foundation of China

Zitieren

APA

Wu, X., Wang, H., Chen, Z., Sun, S., Lian, Z., Zhang, X., Peng, P., & Feng, Y. (2025). A Mixed-attention Network for Automated Interventricular Septum Segmentation in Bright-blood Myocardial T2* MRI Relaxometry in Thalassemia. Academic Radiology. https://doi.org/10.1016/j.acra.2025.04.075

Vancouver

Wu X, Wang H, Chen Z, Sun S, Lian Z, Zhang X, et al. A Mixed-attention Network for Automated Interventricular Septum Segmentation in Bright-blood Myocardial T2* MRI Relaxometry in Thalassemia. Academic Radiology. 2025. doi:10.1016/j.acra.2025.04.075

BibTeX
@article{Wu2025,
  author = {Wu, Xiaofeng and Wang, Hangyu and Chen, Zeluan and Sun, Songsong and Lian, Zifeng and Zhang, Xinyuan and Peng, Peng and Feng, Yanqiu},
  title = {A Mixed-attention Network for Automated Interventricular Septum Segmentation in Bright-blood Myocardial T2* MRI Relaxometry in Thalassemia},
  journal = {Academic Radiology},
  year = {2025},
  doi = {10.1016/j.acra.2025.04.075}
}
Kostenlos starten →