EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Quantification of 129Xe MRI Ventilation-defect-percent Using Binary-threshold, Gaussian Linear-Binning and K-means Methods: Differences in Asthma and COPD

Eveline Durom, Chanwoo Yang, Ali Mozaffaripour, Alexander M Matheson, Rachel L Eddy, Sarah Svenningsen, Grace Parraga

Academic Radiology · 2025

DOI: 10.1016/j.acra.2025.04.030 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Academic Radiology, 2025. Verfasst von Eveline Durom und 6 weiteren Autor:innen. Beteiligte Einrichtung: Robarts Research Institute, Western University, London, Canada (E.D., C.Y., A.M., A.M.M., G.P.); School of Biomedical Engineering, Western University…. Hauptthemen laut MEDLINE: Pulmonary Disease, Chronic Obstructive, Asthma, Magnetic Resonance Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

RATIONALE AND OBJECTIVES: Hyperpolarized 129Xe magnetic resonance imaging (MRI) provides a way to quantify ventilation heterogeneity as ventilation defect percent (VDP), calculated as the volume of unventilated lung volume normalized to the thoracic cavity volume. Currently used methods for quantifying VDP include (1) binary signal-intensity thresholds (Binary-threshold, BT), (2) Gaussian transformation of signal-intensity histogram with standard deviation thresholds or Gaussian-linear-binning (GLB), and (3) iterative centroid-based clustering of the signal-intensity histogram (k-means). These methods have not been directly compared in patients with asthma and chronic obstructive pulmonary disease (COPD), in whom ventilation defects are hallmark findings. Our objective was to quantify and compare VDP using these four different methods. PATIENTS AND METHODS: Data from 175 participants (n=42 healthy, n=43 COPD, n=90 asthma) were retrospectively evaluated using a CNN co-registration and segmentation pipeline and GLB, GLBslice, (slice-wise evaluation of GLB) BT and k-means VDP quantification methods. Linear-regression and Bland-Altman plots were used to quantify inter-method correlations and agreement. RESULTS: VDP was significantly different using GLB (Asthma: 6±9%, COPD: 7±7%, p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary Disease, Chronic ObstructiveAsthmaMagnetic Resonance ImagingHumansMaleFemaleMiddle AgedXenon IsotopesRetrospective StudiesAdultAgedImage Interpretation, Computer-AssistedLungNormal Distribution

Stichwörter der Autor:innen

(129)Xe MRIMRIPulmonary imagingVentilation defect percent

Substanzen

Xenon IsotopesXenon-129

Autor:innen und Institutionen

  • Robarts Research Institute, Western University, London, Canada (E.D., C.Y., A.M., A.M.M., G.P.); School of Biomedical Engineering, Western University, London, Canada (E.D., A.M., G.P.).
  • Robarts Research Institute, Western University, London, Canada (E.D., C.Y., A.M., A.M.M., G.P.).
  • Centre for Heart Lung Innovation, St. Paul's Hospital, Vancouver, Canada (R.L.E.).
  • Division of Respirology, Department of Medicine, McMaster University, Hamilton, Canada (S.S.).
  • Robarts Research Institute, Western University, London, Canada (E.D., C.Y., A.M., A.M.M., G.P.); School of Biomedical Engineering, Western University, London, Canada (E.D., A.M., G.P.); Department of Medical Biophysics,…

Zitieren

APA

Durom, E., Yang, C., Mozaffaripour, A., Matheson, A. M., Eddy, R. L., Svenningsen, S., & Parraga, G. (2025). Quantification of 129Xe MRI Ventilation-defect-percent Using Binary-threshold, Gaussian Linear-Binning and K-means Methods: Differences in Asthma and COPD. Academic Radiology. https://doi.org/10.1016/j.acra.2025.04.030

Vancouver

Durom E, Yang C, Mozaffaripour A, Matheson AM, Eddy RL, Svenningsen S, et al. Quantification of 129Xe MRI Ventilation-defect-percent Using Binary-threshold, Gaussian Linear-Binning and K-means Methods: Differences in Asthma and COPD. Academic Radiology. 2025. doi:10.1016/j.acra.2025.04.030

BibTeX
@article{Durom2025,
  author = {Durom, Eveline and Yang, Chanwoo and Mozaffaripour, Ali and Matheson, Alexander M and Eddy, Rachel L and Svenningsen, Sarah and Parraga, Grace},
  title = {Quantification of 129Xe MRI Ventilation-defect-percent Using Binary-threshold, Gaussian Linear-Binning and K-means Methods: Differences in Asthma and COPD},
  journal = {Academic Radiology},
  year = {2025},
  doi = {10.1016/j.acra.2025.04.030}
}
Kostenlos starten →