Diffusion Weighted Imaging for the Assessment of Lymph Node Metastases in Women with Cervical Cancer: A Meta-analysis of the Apparent Diffusion Coefficient Values
Academic Radiology · 2025-03 · 32 (3) · 1465-1475
DOI: 10.1016/j.acra.2024.09.020 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Academic Radiology, 2025-03. Verfasst von Robyn F Distelbrink und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, the Netherlands. El…. Hauptthemen laut MEDLINE: Uterine Cervical Neoplasms, Diffusion Magnetic Resonance Imaging, Lymph Nodes. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
PURPOSE: To assess the diagnostic performance of Diffusion Weighted Imaging (DWI) and provide optimal apparent diffusion coefficient (ADC) cut-off values for differentiating between benign and metastatic lymph nodes in women with uterine cervical cancer. METHOD: MEDLINE and EMBASE databases were searched. Methodological quality was assessed with QUADAS-2. Data analysis was performed for three subgroups: (1) All studies; (2) Studies with maximum b-values of 800 s/mm², and (3) Studies containing b-values of 1000 s/mm². Receiver-operating characteristics (ROC) curves were constructed and the area under the curve (AUC) was calculated. The maximum Youden index was used to determine optimal ADC cut-off values, following calculations of sensitivity and specificity. RESULTS: 16 articles (1156 patients) were included. Overall, their quality was limited. For all studies combined, the optimum ADC cut-off value was 0.985×10⁻³ mm²/s at maximum Youden Index of 0.77, resulting in sensitivity and specificity of 84%, and 94%, respectively. Studies with b-values up to 800 s/mm², gave an optimum ADC cut-off value of 0.985×10⁻³ mm²/s at maximum Youden Index of 0.62, with a sensitivity and specificity of 62%, and 100%. Studies containing b-values of 1000 s/mm² gave an optimum ADC cut-off value of 0.9435×10⁻³ mm²/s at maximum Youden Index of 0.93, with a sensitivity and specificity of 100%, and 93%, respectively. CONCLUSION: Studies using DWI including b-values of 1000 s/mm² have higher sensitivity and specificity than those with b-values up to 800 s/mm². At the cut-off value of 0.9435×10⁻³ mm²/s DWI can sufficiently discriminate between benign and metastatic lymph nodes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, the Netherlands. Electronic address: r.f.distelbrink@amsterdamumc.nl.
- Department of Radiology and Nuclear Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, the Netherlands.
- Department of Gynaecological Oncology, Cancer Centre Amsterdam, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, the Netherlands; Centre of Gynaecologic Oncology Amsterdam (CGOA), Ples…
Zitieren
APA
Distelbrink, R. F., Celebi, E., Mom, C. H., Stoker, J., & Bipat, S. (2025). Diffusion Weighted Imaging for the Assessment of Lymph Node Metastases in Women with Cervical Cancer: A Meta-analysis of the Apparent Diffusion Coefficient Values. Academic Radiology, 32(3), 1465-1475. https://doi.org/10.1016/j.acra.2024.09.020
Vancouver
Distelbrink RF, Celebi E, Mom CH, Stoker J, Bipat S. Diffusion Weighted Imaging for the Assessment of Lymph Node Metastases in Women with Cervical Cancer: A Meta-analysis of the Apparent Diffusion Coefficient Values. Academic Radiology. 2025;32(3):1465-1475. doi:10.1016/j.acra.2024.09.020
BibTeX
@article{Distelbrink2025,
author = {Distelbrink, Robyn F and Celebi, Enise and Mom, Constantijne H and Stoker, Jaap and Bipat, Shandra},
title = {Diffusion Weighted Imaging for the Assessment of Lymph Node Metastases in Women with Cervical Cancer: A Meta-analysis of the Apparent Diffusion Coefficient Values},
journal = {Academic Radiology},
year = {2025},
volume = {32},
number = {3},
pages = {1465--1475},
doi = {10.1016/j.acra.2024.09.020}
}
EUVIMED